title: "Rheem XE40T10HMS00U0 (2.8 UEF, 36 gal)"
url: https://gcsradheat.com/water-heaters/rheem/xe40t10hms00u0/
description: "Engineered as a Electric Hybrid/Electric Heat Pump unit, Rheem XE40T10HMS00U0 achieves a certified 2.8 UEF rating across its 36-gallon nominal tank, 45 gal."
---

ENERGY STAR water heater model · PD 3555262

# Rheem XE40T10HMS00U0 Water Heater Specifications (2.8 UEF)

Engineered as a Electric Hybrid/Electric Heat Pump unit, Rheem XE40T10HMS00U0 achieves a certified 2.8 UEF rating across its 36-gallon nominal tank, 45 gal First Hour Rating and ranks #695 of 706 in its 706-model cohort (PD 3555262), recording Pass: +0.50 / +21.7% under 2029 DOE rules. Rated annual electricity draw of 780 kWh/yr equates to roughly $142/yr ($1,416 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH40 T0 FD120-M (2.8 UEF).

- **Uniform Energy Factor**: 2.8 UEF

- **Cohort UEF Rank**: #695 of 706

- **First Hour Rating**: 45 gal

- **Storage Volume**: 36 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +0.50 / +21.7%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Rheem XE40T10HMS00U0 relative to the cohort median.

Efficiency comparison & rule summary

Within the 706-unit Hybrid/Electric Heat Pump cohort, Rheem XE40T10HMS00U0 logs 2.8 UEF and ranks #695 of 706.

Against 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF), Rheem XE40T10HMS00U0 holds a +0.50 UEF (+21.7%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 780 kWh/yr for Rheem XE40T10HMS00U0 runs ~$142/yr vs. ~$431/yr for a 0.92 UEF electric tank.

State electric sensitivity for Rheem XE40T10HMS00U0: 10-year operating spend spans $1,141 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $3,680 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Cross-shopping Rheem XE40T10HMS00U0 (2.8 UEF)? Check Friedrich PROH40 T0 FD120-M (2.8 UEF, at parity) and Richmond 10E40-HP120M (2.8 UEF, at parity).

## How Complete Are the Certified Metrics for Rheem XE40T10HMS00U0?

Standing at #695 of 706 among 706 certified Hybrid/Electric Heat Pump heaters, Rheem XE40T10HMS00U0 brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Rheem](https://gcsradheat.com/brands/rheem/) | 236 certified listings | ENERGY STAR PD 3555262 |
| Model Number | XE40T10HMS00U0 | Draw pattern: Low-Usage | XE40T10HMS00U0 |
| Uniform Energy Factor (UEF) | 2.8 | -0.90 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 45 gal | -27 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 780 kWh/yr | -292 kWh/yr vs. 1,072 kWh/yr median | Est. $142/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 387% | -42.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 62.3" H x 20.3" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 120 V / 4.5 A max | 120V plug-in retrofit circuit; slower heat-pump-only recovery | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-16 | Certified 2026-10-16 | Markets: United States |

## What Is the Projected Utility Bill for XE40T10HMS00U0 by State?

At 780 kWh/yr, Rheem XE40T10HMS00U0 averages about $142/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $142/yr | $1,416 | $2,895 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $368/yr | $3,680 | $7,520 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $232/yr | $2,320 | $4,742 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $124/yr | $1,241 | $2,536 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $114/yr | $1,141 | $2,332 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (780 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Are Rheem Models Affected by Current CPSC Notices?

Review 4 brand-matched CPSC entries pulled 2026-11-23 for Rheem and confirm your serial tag before scheduling contractor service. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

**4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range**

- **Recall #16177 (2016-05-26):** Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards; Sold Exclusively at Home Depot ([CPSC Notice](https://www.cpsc.gov/Recalls/2016/Rheem-Recalls-to-Repair-Water-Heaters))
- **Recall #07108 (2007-02-21):** Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard ([CPSC Notice](https://www.cpsc.gov/Recalls/2007/Tankless-Water-Heaters-Recalled-for-Repair-Due-to-Carbon-Monoxide-Poisoning-Hazard))
- **Recall #05274 (2005-09-16):** CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters ([CPSC Notice](https://www.cpsc.gov/Recalls/2005/CPSC-Robertshaw-Controls-Co-Announce-Recall-of-Gas-Control-Valves-on-Water-Heaters-))
- **Recall #80042 (1980-12-04):** LP Gas Water Heaters Repaired by White-Rodgers ([CPSC Notice](https://www.cpsc.gov/Recalls/1981/Explosion-Hazard-Results-In-Repair-Program-For-600000-LP-Gas-Water-Heaters-Following-Settlement-Of-Penalty-At-420000))

## Which 5 Models Offer Similar Output to XE40T10HMS00U0?

Ordered by minimal capacity and UEF spread relative to Rheem XE40T10HMS00U0, these five certified peers give direct replacement benchmarks.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Friedrich PROH40 T0 FD120-M](https://gcsradheat.com/water-heaters/friedrich/proh40-t0-fd120-m/) | Hybrid/Electric Heat Pump | 36 gal | 45 gal | 2.8 (at parity) | 780 |
| [Richmond 10E40-HP120M](https://gcsradheat.com/water-heaters/richmond/10e40-hp120m/) | Hybrid/Electric Heat Pump | 36 gal | 45 gal | 2.8 (at parity) | 780 |
| [Ruud PROUH40 T0 RU120-M](https://gcsradheat.com/water-heaters/ruud/prouh40-t0-ru120-m/) | Hybrid/Electric Heat Pump | 36 gal | 45 gal | 2.8 (at parity) | 780 |
| [A. O. Smith CAHP-40 2**](https://gcsradheat.com/water-heaters/a-o-smith/cahp-40-2/) | Hybrid/Electric Heat Pump | 36 gal | 55 gal | 3.6 (+0.80) | 902 |
| [Friedrich PROH40 T0 FD120-MSO](https://gcsradheat.com/water-heaters/friedrich/proh40-t0-fd120-mso/) | Hybrid/Electric Heat Pump | 36 gal | 45 gal | 2.8 (at parity) | 780 |

## What Installation Caveats Apply Before Buying Rheem XE40T10HMS00U0?

Even high-UEF units like Rheem XE40T10HMS00U0 (2.8 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

### Key Limitations & Exclusions

- Rheem XE40T10HMS00U0 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Rheem XE40T10HMS00U0 directly beside quiet bedrooms.
- Requires condensate drain routing and 120V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing Rheem XE40T10HMS00U0** Strong Fit — 2.8 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare Friedrich PROH40 T0 FD120-M footprint.

## Practical Specs & Code Questions for Rheem XE40T10HMS00U0

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Is Rheem XE40T10HMS00U0 eligible for continued manufacture past May 6, 2029?

At 2.8 UEF, Rheem XE40T10HMS00U0 achieves Pass: +0.50 / +21.7% for the 2029 DOE standard and stands #695 of 706 against Friedrich PROH40 T0 FD120-M and Richmond 10E40-HP120M.

### How tall and wide is Rheem XE40T10HMS00U0, and what service clearance is needed?

Physical dimensions for Rheem XE40T10HMS00U0 are 62.3 in. height and 20.3 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" d)); verify stair turns and drain pan width before delivery.

### Will Rheem XE40T10HMS00U0 require upgrading household electrical panels or gas piping?

Rheem XE40T10HMS00U0 draws 120V at 4.5A max (120V plug-in retrofit circuit; slower heat-pump-only recovery); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.

### Is Rheem XE40T10HMS00U0 economical to operate at 18.16 cents/kWh US electric rates?

Expect roughly $142/yr ($1,420 over 10 years) to power Rheem XE40T10HMS00U0 at 780 kWh/yr under the 18.16 cents/kWh US average (ranging from $114/yr in Washington hydro tiers up to $368/yr in Hawaii).

### Which installation bottlenecks limit Rheem XE40T10HMS00U0?

If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, Rheem XE40T10HMS00U0 drops into resistance mode more often.

### How does Rheem XE40T10HMS00U0 handle simultaneous showers and laundry?

Delivering 45 gal in the first hour (-27 gal vs. 72 gal median), Rheem XE40T10HMS00U0 combines 36 gal tank storage with rapid burner/element recovery.

### How long is the warranty on Rheem XE40T10HMS00U0 and how do you decode its serial?

CPSC SaferProducts records show 4 brand-level recall notices mentioning Rheem as of 2026-11-23, including #16177 (2016-05-26). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

### How do 2026 post-OBBBA rebates affect buying Rheem XE40T10HMS00U0?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH40 T0 FD120-M (2.8 UEF).

## Installation, Serial & DOE 2029 Links for XE40T10HMS00U0

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Friedrich PROH40 T0 FD120-M (2.8 UEF)→](https://gcsradheat.com/water-heaters/friedrich/proh40-t0-fd120-m/)
- [Compare Richmond 10E40-HP120M (2.8 UEF)→](https://gcsradheat.com/water-heaters/richmond/10e40-hp120m/)
- [View All Rheem Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/rheem/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)