title: "Rheem XE65T10HZ45U1 (4.05 UEF, 59 gal)"
url: https://gcsradheat.com/water-heaters/rheem/xe65t10hz45u1/
description: "Engineered as a Electric Hybrid/Electric Heat Pump unit, Rheem XE65T10HZ45U1 achieves a certified 4.05 UEF rating across its 59-gallon nominal tank, 75 gal."
---

ENERGY STAR water heater model · PD 4692187

# Rheem XE65T10HZ45U1 Water Heater Specifications (4.05 UEF)

Engineered as a Electric Hybrid/Electric Heat Pump unit, Rheem XE65T10HZ45U1 achieves a certified 4.05 UEF rating across its 59-gallon nominal tank, 75 gal First Hour Rating and ranks #61 of 706 in its 706-model cohort (PD 4692187), recording Pass: +1.55 / +62.0% under 2029 DOE rules. Rated annual electricity draw of 1,184 kWh/yr equates to roughly $215/yr ($2,150 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH65 T2 FD400-30 (4.05 UEF).

- **Uniform Energy Factor**: 4.05 UEF

- **Cohort UEF Rank**: #61 of 706 (top 14.2%)

- **First Hour Rating**: 75 gal

- **Storage Volume**: 59 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.55 / +62.0%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Rheem XE65T10HZ45U1 relative to the cohort median.

Efficiency comparison & rule summary

Within the 706-unit Hybrid/Electric Heat Pump cohort, Rheem XE65T10HZ45U1 logs 4.05 UEF and ranks #61 of 706.

Against 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF), Rheem XE65T10HZ45U1 holds a +1.55 UEF (+62.0%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 1,184 kWh/yr for Rheem XE65T10HZ45U1 runs ~$215/yr vs. ~$946/yr for a 0.92 UEF electric tank.

State electric sensitivity for Rheem XE65T10HZ45U1: 10-year operating spend spans $1,732 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,586 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Cross-shopping Rheem XE65T10HZ45U1 (4.05 UEF)? Check Friedrich PROH65 T2 FD400-30 (4.05 UEF, at parity) and Richmond 10CE65-HP5S30 (4.05 UEF, at parity).

## How Do Rheem XE65T10HZ45U1 Specs Compare to Hybrid/Electric Heat Pump Medians?

Rheem XE65T10HZ45U1 places #61 of 706 (top 14.2%) across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Rheem](https://gcsradheat.com/brands/rheem/) | 236 certified listings | ENERGY STAR PD 4692187 |
| Model Number | XE65T10HZ45U1 | Draw pattern: High-Usage | XE65T10HZ45U1 |
| Uniform Energy Factor (UEF) | 4.05 | +0.35 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 75 gal | +3 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,184 kWh/yr | +112 kWh/yr vs. 1,072 kWh/yr median | Est. $215/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 457% | +28.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 64.2" H x 24.3" D | Verify 72 in. vertical headroom; clears 28 in. utility doorway (24.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-1234YF | Lower-GWP refrigerant alignment (EPA AIM Act) | EPA AIM Act Compliance |
| Certification Date | 2026-10-15 | Certified 2026-10-15 | Markets: United States |

## What Does XE65T10HZ45U1 Cost to Operate Across State Electricity Rates?

At 1,184 kWh/yr, Rheem XE65T10HZ45U1 runs roughly $215/yr on the EIA national average tier under August 2026 Table 5.6.A rates.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $215/yr | $2,150 | $7,315 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $559/yr | $5,586 | $19,004 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $352/yr | $3,522 | $11,983 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $188/yr | $1,884 | $6,409 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $173/yr | $1,732 | $5,893 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (1,184 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Are There Active CPSC Safety Recalls for Rheem Water Heaters?

Our 2026-11-23 CPSC SaferProducts query surfaced 4 brand-level recall notices associated with Rheem; match your serial plate before repair. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

**4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range**

- **Recall #16177 (2016-05-26):** Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards; Sold Exclusively at Home Depot ([CPSC Notice](https://www.cpsc.gov/Recalls/2016/Rheem-Recalls-to-Repair-Water-Heaters))
- **Recall #07108 (2007-02-21):** Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard ([CPSC Notice](https://www.cpsc.gov/Recalls/2007/Tankless-Water-Heaters-Recalled-for-Repair-Due-to-Carbon-Monoxide-Poisoning-Hazard))
- **Recall #05274 (2005-09-16):** CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters ([CPSC Notice](https://www.cpsc.gov/Recalls/2005/CPSC-Robertshaw-Controls-Co-Announce-Recall-of-Gas-Control-Valves-on-Water-Heaters-))
- **Recall #80042 (1980-12-04):** LP Gas Water Heaters Repaired by White-Rodgers ([CPSC Notice](https://www.cpsc.gov/Recalls/1981/Explosion-Hazard-Results-In-Repair-Program-For-600000-LP-Gas-Water-Heaters-Following-Settlement-Of-Penalty-At-420000))

## Which Certified Water Heaters Match XE65T10HZ45U1 Most Closely?

These 5 competing Hybrid/Electric Heat Pump units sit nearest to Rheem XE65T10HZ45U1 by storage capacity and 4.05 UEF rating.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Friedrich PROH65 T2 FD400-30](https://gcsradheat.com/water-heaters/friedrich/proh65-t2-fd400-30/) | Hybrid/Electric Heat Pump | 59 gal | 75 gal | 4.05 (at parity) | 1,184 |
| [Richmond 10CE65-HP5S30](https://gcsradheat.com/water-heaters/richmond/10ce65-hp5s30/) | Hybrid/Electric Heat Pump | 59 gal | 75 gal | 4.05 (at parity) | 1,289 |
| [Ruud CPROPH65 T2 CD375-30](https://gcsradheat.com/water-heaters/ruud/cproph65-t2-cd375-30/) | Hybrid/Electric Heat Pump | 59 gal | 75 gal | 4.05 (at parity) | 1,213 |
| [Bosch TR7000T-65CA](https://gcsradheat.com/water-heaters/bosch/tr7000t-65ca/) | Hybrid/Electric Heat Pump | 60 gal | 80 gal | 3.9 (-0.15) | 1,240 |
| [Friedrich PROH65 T2 FD400-SO](https://gcsradheat.com/water-heaters/friedrich/proh65-t2-fd400-so/) | Hybrid/Electric Heat Pump | 59 gal | 75 gal | 4.05 (at parity) | 1,184 |

## Which Home Setups Are NOT a Fit for Rheem XE65T10HZ45U1?

Comparing Rheem XE65T10HZ45U1 against Friedrich PROH65 T2 FD400-30 requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

### Key Limitations & Exclusions

- Rheem XE65T10HZ45U1 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Rheem XE65T10HZ45U1 directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing Rheem XE65T10HZ45U1** Strong Fit — 4.05 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare Friedrich PROH65 T2 FD400-30 footprint.

## What Are the Key Questions About Rheem XE65T10HZ45U1?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### How does Rheem XE65T10HZ45U1 score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; Rheem XE65T10HZ45U1 logs 4.05 UEF (Pass: +1.55 / +62.0%) within the 706-unit Hybrid/Electric Heat Pump group.

### What physical clearance dimensions apply when installing Rheem XE65T10HZ45U1?

With a 64.2 in. height and 24.3 in. diameter, Rheem XE65T10HZ45U1 fits spaces matching: verify 72 in. vertical headroom; clears 28 in. utility doorway (24.3" d), plus 6–12 in. above for plumbing shutoffs.

### What 240V circuit or IFGC fuel line capacity fits Rheem XE65T10HZ45U1?

Powered via 240V at 21A max, Rheem XE65T10HZ45U1 requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.

### How do state electricity prices change annual costs for Rheem XE65T10HZ45U1?

Annual electric spend for Rheem XE65T10HZ45U1 (1,184 kWh/yr) averages $215/yr nationwide (ranging from $173/yr in Washington hydro tiers up to $559/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.

### What homeowner setups should avoid choosing Rheem XE65T10HZ45U1?

Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on Rheem XE65T10HZ45U1.

### Is Rheem XE65T10HZ45U1 sized adequately for a 2-to-4-person household?

ENERGY STAR certifies Rheem XE65T10HZ45U1 at 75 gal First Hour Rating (+3 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.

### Does Rheem have active CPSC SaferProducts notices affecting XE65T10HZ45U1?

CPSC SaferProducts records show 4 brand-level recall notices mentioning Rheem as of 2026-11-23, including #16177 (2016-05-26). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

### Which competing water heater matches Rheem XE65T10HZ45U1 (4.05 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for Rheem XE65T10HZ45U1. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH65 T2 FD400-30 (4.05 UEF).

## Which Sizing and Compliance Guides Pair with XE65T10HZ45U1?

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Friedrich PROH65 T2 FD400-30 (4.05 UEF)→](https://gcsradheat.com/water-heaters/friedrich/proh65-t2-fd400-30/)
- [Compare Richmond 10CE65-HP5S30 (4.05 UEF)→](https://gcsradheat.com/water-heaters/richmond/10ce65-hp5s30/)
- [View All Rheem Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/rheem/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)