title: "Richmond 10CE40-HP5US30 (3.83 UEF, 36 gal)"
url: https://gcsradheat.com/water-heaters/richmond/10ce40-hp5us30/
description: "With PD 4572778 certification, Richmond 10CE40-HP5US30 (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.83 UEF rating across its 36-gallon nominal."
---

ENERGY STAR water heater model · PD 4572778

# Richmond 10CE40-HP5US30 Water Heater Specifications (3.83 UEF)

With PD 4572778 certification, Richmond 10CE40-HP5US30 (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.83 UEF rating across its 36-gallon nominal tank, 60 gal First Hour Rating, standing #230 of 706 across 706 peers with Pass: +1.53 / +66.5% for May 6, 2029. Rated annual electricity draw of 859 kWh/yr equates to roughly $156/yr ($1,560 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH40 T2 FD400-30 (3.83 UEF).

- **Uniform Energy Factor**: 3.83 UEF

- **Cohort UEF Rank**: #230 of 706 (top 37.8%)

- **First Hour Rating**: 60 gal

- **Storage Volume**: 36 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.53 / +66.5%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Richmond 10CE40-HP5US30 relative to the cohort median.

Efficiency comparison & rule summary

ENERGY STAR certification places Richmond 10CE40-HP5US30 at 3.83 UEF (#230 of 706; +0.13 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.

May 6, 2029 readiness: Richmond 10CE40-HP5US30 stands +1.53 UEF (+66.5%) relative to 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 859 kWh/yr for Richmond 10CE40-HP5US30 runs ~$156/yr vs. ~$649/yr for a 0.92 UEF electric tank.

State electric sensitivity for Richmond 10CE40-HP5US30: 10-year operating spend spans $1,257 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,053 in Hawaii (Highest EIA State) (47.18 cents/kWh).

In the Hybrid/Electric Heat Pump tier, Friedrich PROH40 T2 FD400-30 (3.83 UEF, at parity) and Rheem CPROPH40 T2 RH400-30 (3.83 UEF, at parity) bracket Richmond 10CE40-HP5US30.

## How Do Richmond 10CE40-HP5US30 Specs Compare to Hybrid/Electric Heat Pump Medians?

Richmond 10CE40-HP5US30 places #230 of 706 (top 37.8%) across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Richmond](https://gcsradheat.com/brands/richmond/) | 80 certified listings | ENERGY STAR PD 4572778 |
| Model Number | 10CE40-HP5US30 | Draw pattern: Medium-Usage | 10CE40-HP5US30 |
| Uniform Energy Factor (UEF) | 3.83 | +0.13 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 60 gal | -12 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 859 kWh/yr | -213 kWh/yr vs. 1,072 kWh/yr median | Est. $156/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 434% | +5.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 62.3" H x 20.3" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-03-24 | Certified 2026-03-24 | Markets: Canada |

## What Does 10CE40-HP5US30 Cost to Operate Across State Electricity Rates?

At 859 kWh/yr, Richmond 10CE40-HP5US30 runs roughly $156/yr on the EIA national average tier under August 2026 Table 5.6.A rates.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $156/yr | $1,560 | $4,934 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $405/yr | $4,053 | $12,819 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $256/yr | $2,556 | $8,083 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $137/yr | $1,367 | $4,323 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $126/yr | $1,257 | $3,975 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (859 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Are There Active CPSC Safety Recalls for Richmond Water Heaters?

Zero active CPSC recalls matched Richmond in our 2026-11-23 SaferProducts sweep; verify your individual tank date code via our lookup tool. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## Which Certified Water Heaters Match 10CE40-HP5US30 Most Closely?

These 5 competing Hybrid/Electric Heat Pump units sit nearest to Richmond 10CE40-HP5US30 by storage capacity and 3.83 UEF rating.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Friedrich PROH40 T2 FD400-30](https://gcsradheat.com/water-heaters/friedrich/proh40-t2-fd400-30/) | Hybrid/Electric Heat Pump | 36 gal | 60 gal | 3.83 (at parity) | 859 |
| [Rheem CPROPH40 T2 RH400-30](https://gcsradheat.com/water-heaters/rheem/cproph40-t2-rh400-30/) | Hybrid/Electric Heat Pump | 36 gal | 60 gal | 3.83 (at parity) | 859 |
| [Ruud CPROPH40 T2 CD375-30](https://gcsradheat.com/water-heaters/ruud/cproph40-t2-cd375-30/) | Hybrid/Electric Heat Pump | 36 gal | 60 gal | 3.83 (at parity) | 859 |
| [A. O. Smith CAHP-40 2**](https://gcsradheat.com/water-heaters/a-o-smith/cahp-40-2/) | Hybrid/Electric Heat Pump | 36 gal | 55 gal | 3.6 (-0.23) | 902 |
| [Friedrich PROH40 T2 FD400-SO](https://gcsradheat.com/water-heaters/friedrich/proh40-t2-fd400-so/) | Hybrid/Electric Heat Pump | 36 gal | 60 gal | 3.83 (at parity) | 859 |

## What Are the Limitations of Richmond 10CE40-HP5US30 and Who Should Not Install It?

Before ordering Richmond 10CE40-HP5US30 (Hybrid/Electric Heat Pump, 3.83 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.

### Key Limitations & Exclusions

- Richmond 10CE40-HP5US30 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Richmond 10CE40-HP5US30 directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing Richmond 10CE40-HP5US30** Strong Fit — 3.83 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare Friedrich PROH40 T2 FD400-30 footprint.

## What Are the Key Questions About Richmond 10CE40-HP5US30?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Does Richmond 10CE40-HP5US30 pass the May 6, 2029 federal DOE efficiency rule?

Richmond 10CE40-HP5US30 carries a verified 3.83 UEF rating (Pass: +1.53 / +66.5%), ranking #230 of 706 (top 37.8%) across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.

### What doorway width and ceiling height does Richmond 10CE40-HP5US30 need?

Richmond 10CE40-HP5US30 stands 62.3 in. high with a 20.3 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.

### What gas pipe size or electrical breaker does Richmond 10CE40-HP5US30 require?

Richmond 10CE40-HP5US30 uses a 240V branch circuit at 21A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.

### How much electricity or energy does Richmond 10CE40-HP5US30 cost per year to run?

Rated at 859 kWh/yr, Richmond 10CE40-HP5US30 costs about $156/yr ($1,560 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $126/yr in Washington hydro tiers up to $405/yr in Hawaii).

### Who should NOT install Richmond 10CE40-HP5US30, and what are its limits?

Richmond 10CE40-HP5US30 (3.83 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.

### How many bathrooms or people can Richmond 10CE40-HP5US30 serve at peak demand?

Richmond 10CE40-HP5US30 achieves a 60 gal First Hour Rating (-12 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.

### Are there CPSC safety recalls or serial checks for Richmond 10CE40-HP5US30?

No active CPSC recalls matched Richmond as of 2026-11-23. Always decode the serial tag on Richmond 10CE40-HP5US30 because OEM tank/exchanger warranties span 6–12 years.

### What 2026 rebates apply to Richmond 10CE40-HP5US30, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH40 T2 FD400-30 (3.83 UEF).

## Which Sizing and Compliance Guides Pair with 10CE40-HP5US30?

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Friedrich PROH40 T2 FD400-30 (3.83 UEF)→](https://gcsradheat.com/water-heaters/friedrich/proh40-t2-fd400-30/)
- [Compare Rheem CPROPH40 T2 RH400-30 (3.83 UEF)→](https://gcsradheat.com/water-heaters/rheem/cproph40-t2-rh400-30/)
- [View All Richmond Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/richmond/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)