title: "Richmond 10E40-HP5S30 (3.83 UEF, 36 gal)"
url: https://gcsradheat.com/water-heaters/richmond/10e40-hp5s30/
description: "The Richmond 10E40-HP5S30 (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.83 UEF rating across its 36-gallon nominal tank, 60 gal First Hour."
---

ENERGY STAR water heater model · PD 2408930

# Richmond 10E40-HP5S30 Water Heater Specifications (3.83 UEF)

The Richmond 10E40-HP5S30 (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.83 UEF rating across its 36-gallon nominal tank, 60 gal First Hour Rating, ranking #230 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 2408930). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +1.53 / +66.5%. Rated annual electricity draw of 859 kWh/yr equates to roughly $156/yr ($1,560 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH40 T2 FD400-30 (3.83 UEF).

- **Uniform Energy Factor**: 3.83 UEF

- **Cohort UEF Rank**: #230 of 706 (top 37.8%)

- **First Hour Rating**: 60 gal

- **Storage Volume**: 36 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.53 / +66.5%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Richmond 10E40-HP5S30 relative to the cohort median.

Efficiency comparison & rule summary

Richmond 10E40-HP5S30 (3.83 UEF) ranks #230 of 706 Hybrid/Electric Heat Pump models — 38-way tie; top 37.8%, more efficient than 62.2% of Hybrid/Electric Heat Pump models, +0.13 UEF above the 3.70 UEF median.

Federal 2029 margin for Richmond 10E40-HP5S30: +1.53 UEF (+66.5%) vs. 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 859 kWh/yr for Richmond 10E40-HP5S30 runs ~$156/yr vs. ~$649/yr for a 0.92 UEF electric tank.

State electric sensitivity for Richmond 10E40-HP5S30: 10-year operating spend spans $1,257 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,053 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Peer comparison: Richmond 10E40-HP5S30 (3.83 UEF) compares closely with Friedrich PROH40 T2 FD400-30 (3.83 UEF, at parity) and Rheem CPROPH40 T2 RH400-30 (3.83 UEF, at parity).

## Where Does Richmond 10E40-HP5S30 Rank Against Peer Hybrid/Electric Heat Pump Units?

Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, Richmond 10E40-HP5S30 holds #230 of 706 (top 37.8%); inspect footprint, circuit load, and efficiency deltas here.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Richmond](https://gcsradheat.com/brands/richmond/) | 80 certified listings | ENERGY STAR PD 2408930 |
| Model Number | 10E40-HP5S30 | Draw pattern: Medium-Usage | 10E40-HP5S30 |
| Uniform Energy Factor (UEF) | 3.83 | +0.13 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 60 gal | -12 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 859 kWh/yr | -213 kWh/yr vs. 1,072 kWh/yr median | Est. $156/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 434% | +5.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 62.3" H x 20.3" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-15 | Certified 2026-10-15 | Markets: United States |

## How Much Electricity Does 10E40-HP5S30 Use in Different States?

Estimated at $156/yr nationally (859 kWh/yr), 10-year utility spending for Richmond 10E40-HP5S30 shifts sharply between low-rate hydro and coastal grids.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $156/yr | $1,560 | $4,934 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $405/yr | $4,053 | $12,819 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $256/yr | $2,556 | $8,083 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $137/yr | $1,367 | $4,323 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $126/yr | $1,257 | $3,975 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (859 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Does CPSC Flag Any Safety Notices on Richmond Units?

No open CPSC recall alerts appeared for Richmond as of 2026-11-23; you can still decode exact manufacture month and warranty window below. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## Which Competing Hybrid/Electric Heat Pump Models Compare Closest to 10E40-HP5S30?

Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to Richmond 10E40-HP5S30's gallon capacity and 3.83 UEF efficiency.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Friedrich PROH40 T2 FD400-30](https://gcsradheat.com/water-heaters/friedrich/proh40-t2-fd400-30/) | Hybrid/Electric Heat Pump | 36 gal | 60 gal | 3.83 (at parity) | 859 |
| [Rheem CPROPH40 T2 RH400-30](https://gcsradheat.com/water-heaters/rheem/cproph40-t2-rh400-30/) | Hybrid/Electric Heat Pump | 36 gal | 60 gal | 3.83 (at parity) | 859 |
| [Ruud CPROPH40 T2 CD375-30](https://gcsradheat.com/water-heaters/ruud/cproph40-t2-cd375-30/) | Hybrid/Electric Heat Pump | 36 gal | 60 gal | 3.83 (at parity) | 859 |
| [A. O. Smith CAHP-40 2**](https://gcsradheat.com/water-heaters/a-o-smith/cahp-40-2/) | Hybrid/Electric Heat Pump | 36 gal | 55 gal | 3.6 (-0.23) | 902 |
| [Friedrich PROH40 T2 FD400-SO](https://gcsradheat.com/water-heaters/friedrich/proh40-t2-fd400-so/) | Hybrid/Electric Heat Pump | 36 gal | 60 gal | 3.83 (at parity) | 859 |

## When Should Homeowners Skip Richmond 10E40-HP5S30 (Hybrid/Electric Heat Pump)?

Check Richmond 10E40-HP5S30's mechanical constraints—including utility space, Electric capacity, and Pass: +1.53 / +66.5% status—against typical residential installations.

### Key Limitations & Exclusions

- Richmond 10E40-HP5S30 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Richmond 10E40-HP5S30 directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing Richmond 10E40-HP5S30** Strong Fit — 3.83 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare Friedrich PROH40 T2 FD400-30 footprint.

## Common Homeowner Questions for Richmond 10E40-HP5S30

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Will Richmond 10E40-HP5S30 stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 3.83 UEF, Richmond 10E40-HP5S30 shows Pass: +1.53 / +66.5% relative to May 6, 2029 federal DOE limits while placing #230 of 706 (top 37.8%) among 706 Hybrid/Electric Heat Pump peers like Friedrich PROH40 T2 FD400-30.

### Will Richmond 10E40-HP5S30 fit through a standard utility door and 72-inch basement ceiling?

Measuring 62.3 in. tall by 20.3 in. diameter, Richmond 10E40-HP5S30 notes: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" d). Reserve space above the jacket for T&P piping and anode removal.

### Do existing utility hookups support Richmond 10E40-HP5S30 during replacement?

Electrical specs for Richmond 10E40-HP5S30 call for 240V at 21A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.

### What is the estimated 10-year operating spend for Richmond 10E40-HP5S30?

At 18.16 cents/kWh national residential pricing, Richmond 10E40-HP5S30's 859 kWh/yr draw equals roughly $156 annually or $1,560 across a 10-year horizon (ranging from $126/yr in Washington hydro tiers up to $405/yr in Hawaii).

### When is Richmond 10E40-HP5S30 a poor fit for a residential replacement?

Avoid placing Richmond 10E40-HP5S30 directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.

### What First Hour Rating or flow capacity does Richmond 10E40-HP5S30 deliver?

With 60 gal FHR (-12 gal vs. 72 gal median), Richmond 10E40-HP5S30 fits 1–3 person or moderate-draw homes cleanly.

### How do you verify manufacturing age and recall status on Richmond 10E40-HP5S30?

Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for Richmond; verify exact manufacturing week for Richmond 10E40-HP5S30 using the Serial Number Lookup tool.

### Does Richmond 10E40-HP5S30 qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Richmond 10E40-HP5S30. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH40 T2 FD400-30 (3.83 UEF).

## Next Engineering Checks for Richmond Owners

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Friedrich PROH40 T2 FD400-30 (3.83 UEF)→](https://gcsradheat.com/water-heaters/friedrich/proh40-t2-fd400-30/)
- [Compare Rheem CPROPH40 T2 RH400-30 (3.83 UEF)→](https://gcsradheat.com/water-heaters/rheem/cproph40-t2-rh400-30/)
- [View All Richmond Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/richmond/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)