title: "Richmond 10E50-HP120M (3 UEF, 46 gal)"
url: https://gcsradheat.com/water-heaters/richmond/10e50-hp120m/
description: "Certified at 3.0 UEF across its 46-gallon nominal tank, 55 gal First Hour Rating, Richmond 10E50-HP120M (Hybrid/Electric Heat Pump, Electric) places #666 of."
---

ENERGY STAR water heater model · PD 3555176

# Richmond 10E50-HP120M Water Heater Specifications (3 UEF)

Certified at 3.0 UEF across its 46-gallon nominal tank, 55 gal First Hour Rating, Richmond 10E50-HP120M (Hybrid/Electric Heat Pump, Electric) places #666 of 706 out of 706 ENERGY STAR models (PD 3555176). Its May 6, 2029 10 CFR 430.32 status reads Pass: +0.70 / +30.4%. Rated annual electricity draw of 1,072 kWh/yr equates to roughly $195/yr ($1,947 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH50 T0 FD120-M (3.0 UEF).

- **Uniform Energy Factor**: 3.0 UEF

- **Cohort UEF Rank**: #666 of 706

- **First Hour Rating**: 55 gal

- **Storage Volume**: 46 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +0.70 / +30.4%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Richmond 10E50-HP120M relative to the cohort median.

Efficiency comparison & rule summary

Tested at 3.0 UEF, Richmond 10E50-HP120M places #666 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (-0.70 UEF vs. 3.70 UEF median).

Richmond 10E50-HP120M clears 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +0.70 UEF (+30.4% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 1,072 kWh/yr for Richmond 10E50-HP120M runs ~$195/yr vs. ~$635/yr for a 0.92 UEF electric tank.

State electric sensitivity for Richmond 10E50-HP120M: 10-year operating spend spans $1,568 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,058 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Closest alternatives to Richmond 10E50-HP120M include Friedrich PROH50 T0 FD120-M (3.0 UEF, at parity) alongside Rheem PROPH50 T0 RH120-M (3.0 UEF, at parity).

## What Physical and Thermal Ratings Define Richmond 10E50-HP120M?

Positioning at #666 of 706 out of 706 Hybrid/Electric Heat Pump peers, Richmond 10E50-HP120M pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Richmond](https://gcsradheat.com/brands/richmond/) | 80 certified listings | ENERGY STAR PD 3555176 |
| Model Number | 10E50-HP120M | Draw pattern: Medium-Usage | 10E50-HP120M |
| Uniform Energy Factor (UEF) | 3.0 | -0.70 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 55 gal | -17 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,072 kWh/yr | At 1,072 kWh/yr median | Est. $195/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 367% | -62.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 61.8" H x 22.3" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 120 V / 4.5 A max | 120V plug-in retrofit circuit; slower heat-pump-only recovery | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-16 | Certified 2026-10-16 | Markets: United States |

## Why Do State Utility Rates Shift 10E50-HP120M Running Costs?

Consuming 1,072 kWh annually puts Richmond 10E50-HP120M near $195/yr at US baseline tariffs, with multi-state EIA comparisons charted below.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $195/yr | $1,947 | $4,402 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $506/yr | $5,058 | $11,436 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $319/yr | $3,189 | $7,211 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $171/yr | $1,706 | $3,857 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $157/yr | $1,568 | $3,546 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (1,072 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Have Any Richmond Series Triggered CPSC Recalls?

SaferProducts screening on 2026-11-23 returned zero recall matches for Richmond; confirm tank age separately using the rating-plate serial pattern. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## What Are 5 Direct Alternatives to Richmond 10E50-HP120M?

Homeowners cross-shopping Richmond 10E50-HP120M frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Friedrich PROH50 T0 FD120-M](https://gcsradheat.com/water-heaters/friedrich/proh50-t0-fd120-m/) | Hybrid/Electric Heat Pump | 46 gal | 55 gal | 3.0 (at parity) | 1,072 |
| [Rheem PROPH50 T0 RH120-M](https://gcsradheat.com/water-heaters/rheem/proph50-t0-rh120-m/) | Hybrid/Electric Heat Pump | 46 gal | 55 gal | 3.0 (at parity) | 1,072 |
| [Ruud PROUH50 T0 RU120-M](https://gcsradheat.com/water-heaters/ruud/prouh50-t0-ru120-m/) | Hybrid/Electric Heat Pump | 46 gal | 55 gal | 3.0 (at parity) | 1,072 |
| [A. O. Smith HPTV-50 2**](https://gcsradheat.com/water-heaters/a-o-smith/hptv-50-2/) | Hybrid/Electric Heat Pump | 46 gal | 52 gal | 3.0 (at parity) | 1,550 |
| [Friedrich PROH50 T0 FD120-MSO](https://gcsradheat.com/water-heaters/friedrich/proh50-t0-fd120-mso/) | Hybrid/Electric Heat Pump | 46 gal | 55 gal | 3.0 (at parity) | 1,072 |

## When Should Homeowners Skip Richmond 10E50-HP120M (Hybrid/Electric Heat Pump)?

Check Richmond 10E50-HP120M's mechanical constraints—including utility space, Electric capacity, and Pass: +0.70 / +30.4% status—against typical residential installations.

### Key Limitations & Exclusions

- Richmond 10E50-HP120M needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Richmond 10E50-HP120M directly beside quiet bedrooms.
- Requires condensate drain routing and 120V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing Richmond 10E50-HP120M** Strong Fit — 3.0 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare Friedrich PROH50 T0 FD120-M footprint.

## Sizing, Efficiency & Recall Answers for Richmond 10E50-HP120M

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Will Richmond 10E50-HP120M stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 3.0 UEF, Richmond 10E50-HP120M shows Pass: +0.70 / +30.4% relative to May 6, 2029 federal DOE limits while placing #666 of 706 among 706 Hybrid/Electric Heat Pump peers like Friedrich PROH50 T0 FD120-M.

### Will Richmond 10E50-HP120M fit through a standard utility door and 72-inch basement ceiling?

Measuring 61.8 in. tall by 22.3 in. diameter, Richmond 10E50-HP120M notes: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.3" d). Reserve space above the jacket for T&P piping and anode removal.

### Do existing utility hookups support Richmond 10E50-HP120M during replacement?

Electrical specs for Richmond 10E50-HP120M call for 120V at 4.5A max (120V plug-in retrofit circuit; slower heat-pump-only recovery). Have a licensed electrician inspect panel load and wire gauge.

### What is the estimated 10-year operating spend for Richmond 10E50-HP120M?

At 18.16 cents/kWh national residential pricing, Richmond 10E50-HP120M's 1,072 kWh/yr draw equals roughly $195 annually or $1,950 across a 10-year horizon (ranging from $157/yr in Washington hydro tiers up to $506/yr in Hawaii).

### When is Richmond 10E50-HP120M a poor fit for a residential replacement?

Avoid placing Richmond 10E50-HP120M directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.

### What First Hour Rating or flow capacity does Richmond 10E50-HP120M deliver?

With 55 gal FHR (-17 gal vs. 72 gal median), Richmond 10E50-HP120M fits 1–3 person or moderate-draw homes cleanly.

### How do you verify manufacturing age and recall status on Richmond 10E50-HP120M?

Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for Richmond; verify exact manufacturing week for Richmond 10E50-HP120M using the Serial Number Lookup tool.

### Does Richmond 10E50-HP120M qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Richmond 10E50-HP120M. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH50 T0 FD120-M (3.0 UEF).

## Related Rebate, Gas-Line & Serial Tools for 10E50-HP120M

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Friedrich PROH50 T0 FD120-M (3.0 UEF)→](https://gcsradheat.com/water-heaters/friedrich/proh50-t0-fd120-m/)
- [Compare Rheem PROPH50 T0 RH120-M (3.0 UEF)→](https://gcsradheat.com/water-heaters/rheem/proph50-t0-rh120-m/)
- [View All Richmond Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/richmond/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)