title: "Richmond 10E80-HP120M (3.46 UEF, 72 gal)"
url: https://gcsradheat.com/water-heaters/richmond/10e80-hp120m/
description: "In the 706-unit Hybrid/Electric Heat Pump class, Richmond 10E80-HP120M (Electric) achieves a certified 3.46 UEF rating across its 72-gallon nominal tank, 84."
---

ENERGY STAR water heater model · PD 3555359

# Richmond 10E80-HP120M Water Heater Specifications (3.46 UEF)

In the 706-unit Hybrid/Electric Heat Pump class, Richmond 10E80-HP120M (Electric) achieves a certified 3.46 UEF rating across its 72-gallon nominal tank, 84 gal First Hour Rating (rank #549 of 706, PD 3555359) and verifies as Pass: +0.96 / +38.4% for 2029 DOE floors. Rated annual electricity draw of 1,403 kWh/yr equates to roughly $255/yr ($2,548 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH80 T0 FD120-M (3.46 UEF).

- **Uniform Energy Factor**: 3.46 UEF

- **Cohort UEF Rank**: #549 of 706

- **First Hour Rating**: 84 gal

- **Storage Volume**: 72 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +0.96 / +38.4%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Richmond 10E80-HP120M relative to the cohort median.

Efficiency comparison & rule summary

Richmond 10E80-HP120M records 3.46 UEF efficiency, putting it #549 of 706 among 706 Hybrid/Electric Heat Pump peers.

10 CFR 430.32(d)(2) compliance: Richmond 10E80-HP120M exceeds 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +0.96 UEF (+38.4%). At EIA August 2026 national rates (18.16 cents/kWh), 1,403 kWh/yr for Richmond 10E80-HP120M runs ~$255/yr vs. ~$958/yr for a 0.92 UEF electric tank.

State electric sensitivity for Richmond 10E80-HP120M: 10-year operating spend spans $2,053 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,619 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Competing options beside Richmond 10E80-HP120M (3.46 UEF) are Friedrich PROH80 T0 FD120-M (3.46 UEF, at parity) and Rheem PROPH80 T0 RH120-M (3.46 UEF, at parity).

## How Complete Are the Certified Metrics for Richmond 10E80-HP120M?

Standing at #549 of 706 among 706 certified Hybrid/Electric Heat Pump heaters, Richmond 10E80-HP120M brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Richmond](https://gcsradheat.com/brands/richmond/) | 80 certified listings | ENERGY STAR PD 3555359 |
| Model Number | 10E80-HP120M | Draw pattern: High-Usage | 10E80-HP120M |
| Uniform Energy Factor (UEF) | 3.46 | -0.24 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 84 gal | +12 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,403 kWh/yr | +331 kWh/yr vs. 1,072 kWh/yr median | Est. $255/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 393% | -36.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 74.2" H x 24.3" D | Needs >72 in. overhead clearance; clears 28 in. utility doorway (24.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 120 V / 12 A max | 120V plug-in retrofit circuit; slower heat-pump-only recovery | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-16 | Certified 2026-10-16 | Markets: United States, Canada |

## What Is the Projected Utility Bill for 10E80-HP120M by State?

At 1,403 kWh/yr, Richmond 10E80-HP120M averages about $255/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $255/yr | $2,548 | $7,033 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $662/yr | $6,619 | $18,273 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $417/yr | $4,174 | $11,522 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $223/yr | $2,232 | $6,162 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $205/yr | $2,053 | $5,666 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (1,403 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Are Richmond Models Affected by Current CPSC Notices?

Zero brand-level CPSC hazard notices matched Richmond in our 2026-11-23 feed; decode your water heater's serial number below to confirm warranty status. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## Which 5 Models Offer Similar Output to 10E80-HP120M?

Ordered by minimal capacity and UEF spread relative to Richmond 10E80-HP120M, these five certified peers give direct replacement benchmarks.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Friedrich PROH80 T0 FD120-M](https://gcsradheat.com/water-heaters/friedrich/proh80-t0-fd120-m/) | Hybrid/Electric Heat Pump | 72 gal | 84 gal | 3.46 (at parity) | 1,403 |
| [Rheem PROPH80 T0 RH120-M](https://gcsradheat.com/water-heaters/rheem/proph80-t0-rh120-m/) | Hybrid/Electric Heat Pump | 72 gal | 84 gal | 3.46 (at parity) | 1,403 |
| [Ruud PROUH80 T0 RU120-M](https://gcsradheat.com/water-heaters/ruud/prouh80-t0-ru120-m/) | Hybrid/Electric Heat Pump | 72 gal | 84 gal | 3.46 (at parity) | 1,403 |
| [LG APHWC801D](https://gcsradheat.com/water-heaters/lg/aphwc801d/) | Hybrid/Electric Heat Pump | 72 gal | 94 gal | 3.9 (+0.44) | 1,272 |
| [Friedrich PROH80 T0 FD120-MSO](https://gcsradheat.com/water-heaters/friedrich/proh80-t0-fd120-mso/) | Hybrid/Electric Heat Pump | 72 gal | 84 gal | 3.46 (at parity) | 1,403 |

## What Installation Caveats Apply Before Buying Richmond 10E80-HP120M?

Even high-UEF units like Richmond 10E80-HP120M (3.46 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

### Key Limitations & Exclusions

- Richmond 10E80-HP120M needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Richmond 10E80-HP120M directly beside quiet bedrooms.
- Requires condensate drain routing and 120V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing Richmond 10E80-HP120M** Strong Fit — 3.46 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare Friedrich PROH80 T0 FD120-M footprint.

## Practical Specs & Code Questions for Richmond 10E80-HP120M

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Is Richmond 10E80-HP120M eligible for continued manufacture past May 6, 2029?

At 3.46 UEF, Richmond 10E80-HP120M achieves Pass: +0.96 / +38.4% for the 2029 DOE standard and stands #549 of 706 against Friedrich PROH80 T0 FD120-M and Rheem PROPH80 T0 RH120-M.

### How tall and wide is Richmond 10E80-HP120M, and what service clearance is needed?

Physical dimensions for Richmond 10E80-HP120M are 74.2 in. height and 24.3 in. diameter (needs >72 in. overhead clearance; clears 28 in. utility doorway (24.3" d)); verify stair turns and drain pan width before delivery.

### Will Richmond 10E80-HP120M require upgrading household electrical panels or gas piping?

Richmond 10E80-HP120M draws 120V at 12A max (120V plug-in retrofit circuit; slower heat-pump-only recovery); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.

### Is Richmond 10E80-HP120M economical to operate at 18.16 cents/kWh US electric rates?

Expect roughly $255/yr ($2,550 over 10 years) to power Richmond 10E80-HP120M at 1,403 kWh/yr under the 18.16 cents/kWh US average (ranging from $205/yr in Washington hydro tiers up to $662/yr in Hawaii).

### Which installation bottlenecks limit Richmond 10E80-HP120M?

If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, Richmond 10E80-HP120M drops into resistance mode more often.

### How does Richmond 10E80-HP120M handle simultaneous showers and laundry?

Delivering 84 gal in the first hour (+12 gal vs. 72 gal median), Richmond 10E80-HP120M combines 72 gal tank storage with rapid burner/element recovery.

### How long is the warranty on Richmond 10E80-HP120M and how do you decode its serial?

CPSC records show 0 active plumbing recalls for Richmond as of 2026-11-23. Confirm install proof and serial manufacture year on Richmond 10E80-HP120M before calling service.

### How do 2026 post-OBBBA rebates affect buying Richmond 10E80-HP120M?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH80 T0 FD120-M (3.46 UEF).

## Installation, Serial & DOE 2029 Links for 10E80-HP120M

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Friedrich PROH80 T0 FD120-M (3.46 UEF)→](https://gcsradheat.com/water-heaters/friedrich/proh80-t0-fd120-m/)
- [Compare Rheem PROPH80 T0 RH120-M (3.46 UEF)→](https://gcsradheat.com/water-heaters/rheem/proph80-t0-rh120-m/)
- [View All Richmond Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/richmond/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)