title: "Richmond 10E80-HP515 (3.7 UEF, 72 gal)"
url: https://gcsradheat.com/water-heaters/richmond/10e80-hp515/
description: "The Richmond 10E80-HP515 (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.7 UEF rating across its 72-gallon nominal tank, 67 gal First Hour Rating."
---

ENERGY STAR water heater model · PD 2408915

# Richmond 10E80-HP515 Water Heater Specifications (3.7 UEF)

The Richmond 10E80-HP515 (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.7 UEF rating across its 72-gallon nominal tank, 67 gal First Hour Rating, ranking #347 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 2408915). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +1.20 / +48.0%. Rated annual electricity draw of 871 kWh/yr equates to roughly $158/yr ($1,582 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH80 T2 FD400-15 (3.7 UEF).

- **Uniform Energy Factor**: 3.7 UEF

- **Cohort UEF Rank**: #347 of 706

- **First Hour Rating**: 67 gal

- **Storage Volume**: 72 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.20 / +48.0%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Richmond 10E80-HP515 relative to the cohort median.

Efficiency comparison & rule summary

Richmond 10E80-HP515 (3.7 UEF) ranks #347 of 706 Hybrid/Electric Heat Pump models — 42-way tie; more efficient than 45% of Hybrid/Electric Heat Pump models, at the 3.70 UEF median.

Federal 2029 margin for Richmond 10E80-HP515: +1.20 UEF (+48.0%) vs. 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 871 kWh/yr for Richmond 10E80-HP515 runs ~$158/yr vs. ~$636/yr for a 0.92 UEF electric tank.

State electric sensitivity for Richmond 10E80-HP515: 10-year operating spend spans $1,274 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,109 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Peer comparison: Richmond 10E80-HP515 (3.7 UEF) compares closely with Friedrich PROH80 T2 FD400-15 (3.7 UEF, at parity) and Rheem CPROPH80 T2 RH375-15 (3.7 UEF, at parity).

## Where Does Richmond 10E80-HP515 Rank Against Peer Hybrid/Electric Heat Pump Units?

Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, Richmond 10E80-HP515 holds #347 of 706; inspect footprint, circuit load, and efficiency deltas here.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Richmond](https://gcsradheat.com/brands/richmond/) | 80 certified listings | ENERGY STAR PD 2408915 |
| Model Number | 10E80-HP515 | Draw pattern: Medium-Usage | 10E80-HP515 |
| Uniform Energy Factor (UEF) | 3.7 | At 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 67 gal | -5 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 871 kWh/yr | -201 kWh/yr vs. 1,072 kWh/yr median | Est. $158/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 445% | +16.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 74.2" H x 24.3" D | Needs >72 in. overhead clearance; clears 28 in. utility doorway (24.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 12 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-15 | Certified 2026-10-15 | Markets: United States |

## How Much Electricity Does 10E80-HP515 Use in Different States?

Estimated at $158/yr nationally (871 kWh/yr), 10-year utility spending for Richmond 10E80-HP515 shifts sharply between low-rate hydro and coastal grids.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $158/yr | $1,582 | $4,780 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $411/yr | $4,109 | $12,418 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $259/yr | $2,591 | $7,830 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $139/yr | $1,386 | $4,188 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $127/yr | $1,274 | $3,851 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (871 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Does CPSC Flag Any Safety Notices on Richmond Units?

No open CPSC recall alerts appeared for Richmond as of 2026-11-23; you can still decode exact manufacture month and warranty window below. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## Which Competing Hybrid/Electric Heat Pump Models Compare Closest to 10E80-HP515?

Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to Richmond 10E80-HP515's gallon capacity and 3.7 UEF efficiency.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Friedrich PROH80 T2 FD400-15](https://gcsradheat.com/water-heaters/friedrich/proh80-t2-fd400-15/) | Hybrid/Electric Heat Pump | 72 gal | 67 gal | 3.7 (at parity) | 871 |
| [Rheem CPROPH80 T2 RH375-15](https://gcsradheat.com/water-heaters/rheem/cproph80-t2-rh375-15/) | Hybrid/Electric Heat Pump | 72 gal | 67 gal | 3.7 (at parity) | 871 |
| [Ruud PROUH80 T2 CD400-15](https://gcsradheat.com/water-heaters/ruud/prouh80-t2-cd400-15/) | Hybrid/Electric Heat Pump | 72 gal | 67 gal | 3.7 (at parity) | 871 |
| [LG APHWC801D](https://gcsradheat.com/water-heaters/lg/aphwc801d/) | Hybrid/Electric Heat Pump | 72 gal | 94 gal | 3.9 (+0.20) | 1,272 |
| [Rheem CPROPH80 T2 RH400-15](https://gcsradheat.com/water-heaters/rheem/cproph80-t2-rh400-15/) | Hybrid/Electric Heat Pump | 72 gal | 67 gal | 3.7 (at parity) | 871 |

## Which Home Setups Are NOT a Fit for Richmond 10E80-HP515?

Comparing Richmond 10E80-HP515 against Friedrich PROH80 T2 FD400-15 requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

### Key Limitations & Exclusions

- Richmond 10E80-HP515 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Richmond 10E80-HP515 directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing Richmond 10E80-HP515** Strong Fit — 3.7 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare Friedrich PROH80 T2 FD400-15 footprint.

## Common Homeowner Questions for Richmond 10E80-HP515

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### How does Richmond 10E80-HP515 score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; Richmond 10E80-HP515 logs 3.7 UEF (Pass: +1.20 / +48.0%) within the 706-unit Hybrid/Electric Heat Pump group.

### What physical clearance dimensions apply when installing Richmond 10E80-HP515?

With a 74.2 in. height and 24.3 in. diameter, Richmond 10E80-HP515 fits spaces matching: needs >72 in. overhead clearance; clears 28 in. utility doorway (24.3" d), plus 6–12 in. above for plumbing shutoffs.

### What 240V circuit or IFGC fuel line capacity fits Richmond 10E80-HP515?

Powered via 240V at 12A max, Richmond 10E80-HP515 requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.

### How do state electricity prices change annual costs for Richmond 10E80-HP515?

Annual electric spend for Richmond 10E80-HP515 (871 kWh/yr) averages $158/yr nationwide (ranging from $127/yr in Washington hydro tiers up to $411/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.

### What homeowner setups should avoid choosing Richmond 10E80-HP515?

Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on Richmond 10E80-HP515.

### Is Richmond 10E80-HP515 sized adequately for a 2-to-4-person household?

ENERGY STAR certifies Richmond 10E80-HP515 at 67 gal First Hour Rating (-5 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.

### Does Richmond have active CPSC SaferProducts notices affecting 10E80-HP515?

Zero CPSC recall alerts matched Richmond (2026-11-23 check). Keep your Richmond 10E80-HP515 serial code handy to track standard 6-to-12-year OEM warranty coverage.

### Which competing water heater matches Richmond 10E80-HP515 (3.7 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for Richmond 10E80-HP515. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH80 T2 FD400-15 (3.7 UEF).

## Next Engineering Checks for Richmond Owners

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Friedrich PROH80 T2 FD400-15 (3.7 UEF)→](https://gcsradheat.com/water-heaters/friedrich/proh80-t2-fd400-15/)
- [Compare Rheem CPROPH80 T2 RH375-15 (3.7 UEF)→](https://gcsradheat.com/water-heaters/rheem/cproph80-t2-rh375-15/)
- [View All Richmond Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/richmond/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)