title: "Richmond 10E80-HP5US30 (4.07 UEF, 72 gal)"
url: https://gcsradheat.com/water-heaters/richmond/10e80-hp5us30/
description: "With PD 3554243 certification, Richmond 10E80-HP5US30 (Hybrid/Electric Heat Pump, Electric) achieves a certified 4.07 UEF rating across its 72-gallon nominal."
---

ENERGY STAR water heater model · PD 3554243

# Richmond 10E80-HP5US30 Water Heater Specifications (4.07 UEF)

With PD 3554243 certification, Richmond 10E80-HP5US30 (Hybrid/Electric Heat Pump, Electric) achieves a certified 4.07 UEF rating across its 72-gallon nominal tank, 87 gal First Hour Rating, standing #26 of 706 across 706 peers with Pass: +1.57 / +62.8% for May 6, 2029. Rated annual electricity draw of 1,213 kWh/yr equates to roughly $220/yr ($2,203 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH80 T2 FD400-30 (4.07 UEF).

- **Uniform Energy Factor**: 4.07 UEF

- **Cohort UEF Rank**: #26 of 706 (top 8.5%)

- **First Hour Rating**: 87 gal

- **Storage Volume**: 72 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.57 / +62.8%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Richmond 10E80-HP5US30 relative to the cohort median.

Efficiency comparison & rule summary

ENERGY STAR certification places Richmond 10E80-HP5US30 at 4.07 UEF (#26 of 706; +0.37 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.

May 6, 2029 readiness: Richmond 10E80-HP5US30 stands +1.57 UEF (+62.8%) relative to 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,213 kWh/yr for Richmond 10E80-HP5US30 runs ~$220/yr vs. ~$974/yr for a 0.92 UEF electric tank.

State electric sensitivity for Richmond 10E80-HP5US30: 10-year operating spend spans $1,775 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,723 in Hawaii (Highest EIA State) (47.18 cents/kWh).

In the Hybrid/Electric Heat Pump tier, Friedrich PROH80 T2 FD400-30 (4.07 UEF, at parity) and Rheem CPROPH80 T2 RH375-SO (4.07 UEF, at parity) bracket Richmond 10E80-HP5US30.

## How Do Richmond 10E80-HP5US30 Specs Compare to Hybrid/Electric Heat Pump Medians?

Richmond 10E80-HP5US30 places #26 of 706 (top 8.5%) across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Richmond](https://gcsradheat.com/brands/richmond/) | 80 certified listings | ENERGY STAR PD 3554243 |
| Model Number | 10E80-HP5US30 | Draw pattern: High-Usage | 10E80-HP5US30 |
| Uniform Energy Factor (UEF) | 4.07 | +0.37 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 87 gal | +15 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,213 kWh/yr | +141 kWh/yr vs. 1,072 kWh/yr median | Est. $220/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 447% | +18.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 74.2" H x 24.3" D | Needs >72 in. overhead clearance; clears 28 in. utility doorway (24.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-15 | Certified 2026-10-15 | Markets: United States |

## What Does 10E80-HP5US30 Cost to Operate Across State Electricity Rates?

At 1,213 kWh/yr, Richmond 10E80-HP5US30 runs roughly $220/yr on the EIA national average tier under August 2026 Table 5.6.A rates.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $220/yr | $2,203 | $7,542 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $572/yr | $5,723 | $19,594 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $361/yr | $3,609 | $12,355 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $193/yr | $1,930 | $6,607 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $177/yr | $1,775 | $6,076 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (1,213 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Are There Active CPSC Safety Recalls for Richmond Water Heaters?

Zero active CPSC recalls matched Richmond in our 2026-11-23 SaferProducts sweep; verify your individual tank date code via our lookup tool. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## Which Certified Water Heaters Match 10E80-HP5US30 Most Closely?

These 5 competing Hybrid/Electric Heat Pump units sit nearest to Richmond 10E80-HP5US30 by storage capacity and 4.07 UEF rating.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Friedrich PROH80 T2 FD400-30](https://gcsradheat.com/water-heaters/friedrich/proh80-t2-fd400-30/) | Hybrid/Electric Heat Pump | 72 gal | 87 gal | 4.07 (at parity) | 1,213 |
| [Rheem CPROPH80 T2 RH375-SO](https://gcsradheat.com/water-heaters/rheem/cproph80-t2-rh375-so/) | Hybrid/Electric Heat Pump | 72 gal | 87 gal | 4.07 (at parity) | 1,213 |
| [Ruud CPROPH80 T2 CD375-30](https://gcsradheat.com/water-heaters/ruud/cproph80-t2-cd375-30/) | Hybrid/Electric Heat Pump | 72 gal | 87 gal | 4.07 (at parity) | 1,213 |
| [LG APHWC802D](https://gcsradheat.com/water-heaters/lg/aphwc802d/) | Hybrid/Electric Heat Pump | 72 gal | 91 gal | 4.1 (+0.03) | 1,210 |
| [Friedrich PROH80 T2 FD400-SO](https://gcsradheat.com/water-heaters/friedrich/proh80-t2-fd400-so/) | Hybrid/Electric Heat Pump | 72 gal | 87 gal | 4.07 (at parity) | 1,213 |

## When Should Homeowners Skip Richmond 10E80-HP5US30 (Hybrid/Electric Heat Pump)?

Check Richmond 10E80-HP5US30's mechanical constraints—including utility space, Electric capacity, and Pass: +1.57 / +62.8% status—against typical residential installations.

### Key Limitations & Exclusions

- Richmond 10E80-HP5US30 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Richmond 10E80-HP5US30 directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing Richmond 10E80-HP5US30** Strong Fit — 4.07 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare Friedrich PROH80 T2 FD400-30 footprint.

## What Are the Key Questions About Richmond 10E80-HP5US30?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Will Richmond 10E80-HP5US30 stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 4.07 UEF, Richmond 10E80-HP5US30 shows Pass: +1.57 / +62.8% relative to May 6, 2029 federal DOE limits while placing #26 of 706 (top 8.5%) among 706 Hybrid/Electric Heat Pump peers like Friedrich PROH80 T2 FD400-30.

### Will Richmond 10E80-HP5US30 fit through a standard utility door and 72-inch basement ceiling?

Measuring 74.2 in. tall by 24.3 in. diameter, Richmond 10E80-HP5US30 notes: needs >72 in. overhead clearance; clears 28 in. utility doorway (24.3" d). Reserve space above the jacket for T&P piping and anode removal.

### Do existing utility hookups support Richmond 10E80-HP5US30 during replacement?

Electrical specs for Richmond 10E80-HP5US30 call for 240V at 21A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.

### What is the estimated 10-year operating spend for Richmond 10E80-HP5US30?

At 18.16 cents/kWh national residential pricing, Richmond 10E80-HP5US30's 1,213 kWh/yr draw equals roughly $220 annually or $2,200 across a 10-year horizon (ranging from $177/yr in Washington hydro tiers up to $572/yr in Hawaii).

### When is Richmond 10E80-HP5US30 a poor fit for a residential replacement?

Avoid placing Richmond 10E80-HP5US30 directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.

### What First Hour Rating or flow capacity does Richmond 10E80-HP5US30 deliver?

With 87 gal FHR (+15 gal vs. 72 gal median), Richmond 10E80-HP5US30 fits larger 3–5 person homes cleanly.

### How do you verify manufacturing age and recall status on Richmond 10E80-HP5US30?

Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for Richmond; verify exact manufacturing week for Richmond 10E80-HP5US30 using the Serial Number Lookup tool.

### Does Richmond 10E80-HP5US30 qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Richmond 10E80-HP5US30. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH80 T2 FD400-30 (4.07 UEF).

## Which Sizing and Compliance Guides Pair with 10E80-HP5US30?

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Friedrich PROH80 T2 FD400-30 (4.07 UEF)→](https://gcsradheat.com/water-heaters/friedrich/proh80-t2-fd400-30/)
- [Compare Rheem CPROPH80 T2 RH375-SO (4.07 UEF)→](https://gcsradheat.com/water-heaters/rheem/cproph80-t2-rh375-so/)
- [View All Richmond Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/richmond/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)