title: "Richmond 12GUH40-50F* (0.9 UEF, 40 gal)"
url: https://gcsradheat.com/water-heaters/richmond/12guh40-50f/
description: "Engineered as a Natural Gas, Propane Gas Storage unit, Richmond 12GUH40-50F* achieves a certified 0.9 UEF rating across its 40-gallon nominal tank, 88 gal."
---

ENERGY STAR water heater model · PD 2408637

# Richmond 12GUH40-50F* Water Heater Specifications (0.9 UEF)

Engineered as a Natural Gas, Propane Gas Storage unit, Richmond 12GUH40-50F* achieves a certified 0.9 UEF rating across its 40-gallon nominal tank, 88 gal First Hour Rating and ranks #1 of 71 in its 71-model cohort (PD 2408637), recording Pass: +0.32 / +55.2% under 2029 DOE rules. Annual fuel cost depends on regional gas/fuel tariffs and fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" d). Closest certified alternative is Friedrich 12PROG 40-50P FD HE EC3 (0.9 UEF).

- **Uniform Energy Factor**: 0.9 UEF

- **Cohort UEF Rank**: #1 of 71

- **First Hour Rating**: 88 gal

- **Storage Volume**: 40 gal

- **Fuel / Type**: Natural Gas, Propane / Gas Storage

- **DOE 2029 Rule Status**: Pass: +0.32 / +55.2%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Gas Storage UEF Efficiency Distribution (71 Certified Units). Highlighted pin shows Richmond 12GUH40-50F* relative to the cohort median.

Efficiency comparison & rule summary

Within the 71-unit Gas Storage cohort, Richmond 12GUH40-50F* logs 0.9 UEF and ranks #1 of 71.

Richmond 12guh40-50f* stores 40 gal nominal; 88 gal first hour rating (-7 gal vs. 95 gal median); fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" d).

Cross-shopping Richmond 12GUH40-50F* (0.9 UEF)? Check Friedrich 12PROG 40-50P FD HE EC3 (0.9 UEF, at parity) and Rheem ECE G40-50U CN HE* (0.9 UEF, at parity).

## What Physical and Thermal Ratings Define Richmond 12GUH40-50F*?

Positioning at #1 of 71 out of 71 Gas Storage peers, Richmond 12GUH40-50F* pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 71 ENERGY STAR Gas Storage peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Richmond](https://gcsradheat.com/brands/richmond/) | 80 certified listings | ENERGY STAR PD 2408637 |
| Model Number | 12GUH40-50F* | Draw pattern: High-Usage | 12GUH40-50F* |
| Uniform Energy Factor (UEF) | 0.9 | At 0.90 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 88 gal | -7 gal vs. 95 gal median | 10 CFR 430 Recovery Test |
| Thermal Recovery Efficiency | 97% | +3.0 pts vs. 94.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 54.5" H x 21.8" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 7 A max | 120V AC ignition/fan + gas piping check | NEC / Branch circuit check |
| Certification Date | 2024-11-04 | Certified 2024-11-04 | Markets: United States |

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Have Any Richmond Series Triggered CPSC Recalls?

SaferProducts screening on 2026-11-23 returned zero recall matches for Richmond; confirm tank age separately using the rating-plate serial pattern. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## What Are 5 Direct Alternatives to Richmond 12GUH40-50F*?

Homeowners cross-shopping Richmond 12GUH40-50F* frequently review these five Gas Storage models ranked closest on capacity and UEF output.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Friedrich 12PROG 40-50P FD HE EC3](https://gcsradheat.com/water-heaters/friedrich/12prog-40-50p-fd-he-ec3/) | Gas Storage | 40 gal | 88 gal | 0.9 (at parity) | — |
| [Rheem ECE G40-50U CN HE*](https://gcsradheat.com/water-heaters/rheem/ece-g40-50u-cn-he/) | Gas Storage | 40 gal | 88 gal | 0.9 (at parity) | — |
| [Ruud PRO+G40-50P RU HE EC1](https://gcsradheat.com/water-heaters/ruud/pro-g40-50p-ru-he-ec1/) | Gas Storage | 40 gal | 88 gal | 0.9 (at parity) | — |
| [A. O. Smith GC6-PS4050*V 1**](https://gcsradheat.com/water-heaters/a-o-smith/gc6-ps4050-v-1/) | Gas Storage | 38 gal | 86 gal | 0.9 (at parity) | — |
| [Friedrich 12PROG 40-50U FD HE EC3](https://gcsradheat.com/water-heaters/friedrich/12prog-40-50u-fd-he-ec3/) | Gas Storage | 40 gal | 88 gal | 0.9 (at parity) | — |

## What Are the Limitations of Richmond 12GUH40-50F* and Who Should Not Install It?

Before ordering Richmond 12GUH40-50F* (Gas Storage, 0.9 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.

### Key Limitations & Exclusions

- Richmond 12GUH40-50F* logs 0.9 UEF (Pass: +0.32 / +55.2%); check May 6, 2029 10 CFR 430.32 transition status.
- Drain tank sediment yearly and inspect Richmond 12GUH40-50F*'s sacrificial anode rod every 4–6 years.
- Peak simultaneous draws exceeding 88 gal will deplete stored recovery capacity.

### Which Option Fits Your Situation?

**Direct Footprint Replacement for Richmond 12GUH40-50F*** Strong Fit — Matches existing plumbing and vent clearances.

**2026 Post-OBBBA Rebate Buyers** Verify Tier — DOE HEAR ($1,750 max) targets >=2.30 UEF heat pump models like Friedrich 12PROG 40-50P FD HE EC3.

**Very Hard Well Water (>10.5 GPG)** Add Softener / Flush — Schedule 6-month tank sediment drains.

## Sizing, Efficiency & Recall Answers for Richmond 12GUH40-50F*

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Does Richmond 12GUH40-50F* pass the May 6, 2029 federal DOE efficiency rule?

Richmond 12GUH40-50F* carries a verified 0.9 UEF rating (Pass: +0.32 / +55.2%), ranking #1 of 71 across 71 ENERGY STAR Gas Storage models under 10 CFR 430.32.

### What doorway width and ceiling height does Richmond 12GUH40-50F* need?

Richmond 12GUH40-50F* stands 54.5 in. high with a 21.8 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.

### What gas pipe size or electrical breaker does Richmond 12GUH40-50F* require?

Richmond 12GUH40-50F* runs on Natural Gas, Propane (120V AC ignition/fan + gas piping check). Upgrading from a 40K tank to 199K BTU/h tankless demand requires checking IFGC Table 402.4(2), since 1/2 in. iron pipe drops below 199 CFH past 10 ft.

### How much electricity or energy does Richmond 12GUH40-50F* cost per year to run?

ENERGY STAR rates Richmond 12GUH40-50F* as a Natural Gas, Propane heater (0.9 UEF) without an electric kWh figure; annual fuel spend depends on local therm rates and Gas Storage draw.

### Who should NOT install Richmond 12GUH40-50F*, and what are its limits?

Richmond 12GUH40-50F* (0.9 UEF) is not suited for multi-bath marathon draws exceeding its 88 gal capacity or buyers prioritizing May 6, 2029 high-UEF HPWH rebates.

### How many bathrooms or people can Richmond 12GUH40-50F* serve at peak demand?

Richmond 12GUH40-50F* achieves a 88 gal First Hour Rating (-7 gal vs. 95 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.

### Are there CPSC safety recalls or serial checks for Richmond 12GUH40-50F*?

No active CPSC recalls matched Richmond as of 2026-11-23. Always decode the serial tag on Richmond 12GUH40-50F* because OEM tank/exchanger warranties span 6–12 years.

### What 2026 rebates apply to Richmond 12GUH40-50F*, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Gas Storage is Friedrich 12PROG 40-50P FD HE EC3 (0.9 UEF).

## Related Rebate, Gas-Line & Serial Tools for 12GUH40-50F*

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Friedrich 12PROG 40-50P FD HE EC3 (0.9 UEF)→](https://gcsradheat.com/water-heaters/friedrich/12prog-40-50p-fd-he-ec3/)
- [Compare Rheem ECE G40-50U CN HE* (0.9 UEF)→](https://gcsradheat.com/water-heaters/rheem/ece-g40-50u-cn-he/)
- [View All Richmond Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/richmond/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm gas pipe length and CFH capacity (especially 199,000 BTU/h condensing tankless conversions under IFGC Table 402.4) and decode the old unit's serial plate.
[Verify Gas Line (IFGC)](https://gcsradheat.com/tools/gas-pipe-sizing-calculator/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)