title: "Richmond 12GUH50-100F* (0.89 UEF, 50 gal)"
url: https://gcsradheat.com/water-heaters/richmond/12guh50-100f/
description: "Engineered as a Natural Gas, Propane Gas-fired Storage Residential-duty Commercial unit, Richmond 12GUH50-100F* achieves a certified 0.89 UEF rating across its."
---

ENERGY STAR water heater model · PD 2408617

# Richmond 12GUH50-100F* Water Heater Specifications (0.89 UEF)

Engineered as a Natural Gas, Propane Gas-fired Storage Residential-duty Commercial unit, Richmond 12GUH50-100F* achieves a certified 0.89 UEF rating across its 50-gallon nominal tank, 167 gal First Hour Rating and ranks #8 of 71 in its 71-model cohort (PD 2408617), recording Pass: +0.31 / +53.4% under 2029 DOE rules. Annual fuel cost depends on regional gas/fuel tariffs and verify 72 in. vertical headroom; clears 28 in. utility doorway (21.8" d). Closest certified alternative is Friedrich 12PROG 50-100P FD HE EC3 (0.89 UEF).

- **Uniform Energy Factor**: 0.89 UEF

- **Cohort UEF Rank**: #8 of 71

- **First Hour Rating**: 167 gal

- **Storage Volume**: 50 gal

- **Fuel / Type**: Natural Gas, Propane / Gas-fired Storage Residential-duty Commercial

- **DOE 2029 Rule Status**: Pass: +0.31 / +53.4%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Gas-fired Storage Residential-duty Commercial UEF Efficiency Distribution (71 Certified Units). Highlighted pin shows Richmond 12GUH50-100F* relative to the cohort median.

Efficiency comparison & rule summary

Within the 71-unit Gas-fired Storage Residential-duty Commercial cohort, Richmond 12GUH50-100F* logs 0.89 UEF and ranks #8 of 71.

Richmond 12guh50-100f* stores 50 gal nominal; 167 gal first hour rating (+31 gal vs. 136 gal median); verify 72 in. vertical headroom; clears 28 in. utility doorway (21.8" d).

Cross-shopping Richmond 12GUH50-100F* (0.89 UEF)? Check Friedrich 12PROG 50-100P FD HE EC3 (0.89 UEF, at parity) and Rheem ECE G50-100U CN HE EC3 (0.89 UEF, at parity).

## Which Specs Set Richmond 12GUH50-100F* Apart From Cohort Averages?

Ranked #8 of 71 inside the 71-model Gas-fired Storage Residential-duty Commercial cohort, Richmond 12GUH50-100F* is evaluated row by row below against category medians.

Certified model attributes compared against 71 ENERGY STAR Gas-fired Storage Residential-duty Commercial peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Richmond](https://gcsradheat.com/brands/richmond/) | 80 certified listings | ENERGY STAR PD 2408617 |
| Model Number | 12GUH50-100F* | Draw pattern: High-Usage | 12GUH50-100F* |
| Uniform Energy Factor (UEF) | 0.89 | +0.01 UEF vs. 0.88 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 167 gal | +31 gal vs. 136 gal median | 10 CFR 430 Recovery Test |
| Thermal Recovery Efficiency | 96% | +1.0 pts vs. 95.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 65.5" H x 21.8" D | Verify 72 in. vertical headroom; clears 28 in. utility doorway (21.8" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 7 A max | 120V AC ignition/fan + gas piping check | NEC / Branch circuit check |
| Certification Date | 2024-11-04 | Certified 2024-11-04 | Markets: United States |

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## What Should Richmond Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC recall sweep recorded zero brand matches for Richmond; run a quick serial-number check to verify age before replacing wear parts. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## How Do Five Nearby Gas-fired Storage Residential-duty Commercial Models Stack Up?

Five alternative Gas-fired Storage Residential-duty Commercial units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Friedrich 12PROG 50-100P FD HE EC3](https://gcsradheat.com/water-heaters/friedrich/12prog-50-100p-fd-he-ec3/) | Gas-fired Storage Residential-duty Commercial | 50 gal | 167 gal | 0.89 (at parity) | — |
| [Rheem ECE G50-100U CN HE EC3](https://gcsradheat.com/water-heaters/rheem/ece-g50-100u-cn-he-ec3/) | Gas-fired Storage Residential-duty Commercial | 50 gal | 167 gal | 0.89 (at parity) | — |
| [Ruud PROU G50-100* RU HE EC3](https://gcsradheat.com/water-heaters/ruud/prou-g50-100-ru-he-ec3/) | Gas-fired Storage Residential-duty Commercial | 50 gal | 167 gal | 0.89 (at parity) | — |
| [A. O. Smith HDHE-50 4**](https://gcsradheat.com/water-heaters/a-o-smith/hdhe-50-4/) | Gas-fired Storage Residential-duty Commercial | 49 gal | 118 gal | 0.88 (-0.01) | — |
| [Friedrich 12PROG 50-100U FD HE EC3](https://gcsradheat.com/water-heaters/friedrich/12prog-50-100u-fd-he-ec3/) | Gas-fired Storage Residential-duty Commercial | 50 gal | 167 gal | 0.89 (at parity) | — |

## What Are the Limitations of Richmond 12GUH50-100F* and Who Should Not Install It?

Before ordering Richmond 12GUH50-100F* (Gas-fired Storage Residential-duty Commercial, 0.89 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.

### Key Limitations & Exclusions

- Richmond 12GUH50-100F* logs 0.89 UEF (Pass: +0.31 / +53.4%); check May 6, 2029 10 CFR 430.32 transition status.
- Drain tank sediment yearly and inspect Richmond 12GUH50-100F*'s sacrificial anode rod every 4–6 years.
- Peak simultaneous draws exceeding 167 gal will deplete stored recovery capacity.

### Which Option Fits Your Situation?

**Direct Footprint Replacement for Richmond 12GUH50-100F*** Strong Fit — Matches existing plumbing and vent clearances.

**2026 Post-OBBBA Rebate Buyers** Verify Tier — DOE HEAR ($1,750 max) targets >=2.30 UEF heat pump models like Friedrich 12PROG 50-100P FD HE EC3.

**Very Hard Well Water (>10.5 GPG)** Add Softener / Flush — Schedule 6-month tank sediment drains.

## Frequently Asked Technical Questions: Richmond 12GUH50-100F*

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Does Richmond 12GUH50-100F* pass the May 6, 2029 federal DOE efficiency rule?

Richmond 12GUH50-100F* carries a verified 0.89 UEF rating (Pass: +0.31 / +53.4%), ranking #8 of 71 across 71 ENERGY STAR Gas-fired Storage Residential-duty Commercial models under 10 CFR 430.32.

### What doorway width and ceiling height does Richmond 12GUH50-100F* need?

Richmond 12GUH50-100F* stands 65.5 in. high with a 21.8 in. diameter; verify 72 in. vertical headroom; clears 28 in. utility doorway (21.8" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.

### What gas pipe size or electrical breaker does Richmond 12GUH50-100F* require?

Richmond 12GUH50-100F* runs on Natural Gas, Propane (120V AC ignition/fan + gas piping check). Upgrading from a 40K tank to 199K BTU/h tankless demand requires checking IFGC Table 402.4(2), since 1/2 in. iron pipe drops below 199 CFH past 10 ft.

### How much electricity or energy does Richmond 12GUH50-100F* cost per year to run?

ENERGY STAR rates Richmond 12GUH50-100F* as a Natural Gas, Propane heater (0.89 UEF) without an electric kWh figure; annual fuel spend depends on local therm rates and Gas-fired Storage Residential-duty Commercial draw.

### Who should NOT install Richmond 12GUH50-100F*, and what are its limits?

Richmond 12GUH50-100F* (0.89 UEF) is not suited for multi-bath marathon draws exceeding its 167 gal capacity or buyers prioritizing May 6, 2029 high-UEF HPWH rebates.

### How many bathrooms or people can Richmond 12GUH50-100F* serve at peak demand?

Richmond 12GUH50-100F* achieves a 167 gal First Hour Rating (+31 gal vs. 136 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.

### Are there CPSC safety recalls or serial checks for Richmond 12GUH50-100F*?

No active CPSC recalls matched Richmond as of 2026-11-23. Always decode the serial tag on Richmond 12GUH50-100F* because OEM tank/exchanger warranties span 6–12 years.

### What 2026 rebates apply to Richmond 12GUH50-100F*, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Gas-fired Storage Residential-duty Commercial is Friedrich 12PROG 50-100P FD HE EC3 (0.89 UEF).

## Essential Pre-Install Guides for Richmond 12GUH50-100F*

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Friedrich 12PROG 50-100P FD HE EC3 (0.89 UEF)→](https://gcsradheat.com/water-heaters/friedrich/12prog-50-100p-fd-he-ec3/)
- [Compare Rheem ECE G50-100U CN HE EC3 (0.89 UEF)→](https://gcsradheat.com/water-heaters/rheem/ece-g50-100u-cn-he-ec3/)
- [View All Richmond Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/richmond/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm gas pipe length and CFH capacity (especially 199,000 BTU/h condensing tankless conversions under IFGC Table 402.4) and decode the old unit's serial plate.
[Verify Gas Line (IFGC)](https://gcsradheat.com/tools/gas-pipe-sizing-calculator/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)