title: "Richmond 9GUH40-50FN (0.9 UEF, 40 gal)"
url: https://gcsradheat.com/water-heaters/richmond/9guh40-50fn/
description: "Certified at 0.9 UEF across its 40-gallon nominal tank, 88 gal First Hour Rating, Richmond 9GUH40-50FN (Gas Storage, Natural Gas) places #1 of 71 out of 71."
---

ENERGY STAR water heater model · PD 3387616

# Richmond 9GUH40-50FN Water Heater Specifications (0.9 UEF)

Certified at 0.9 UEF across its 40-gallon nominal tank, 88 gal First Hour Rating, Richmond 9GUH40-50FN (Gas Storage, Natural Gas) places #1 of 71 out of 71 ENERGY STAR models (PD 3387616). Its May 6, 2029 10 CFR 430.32 status reads Pass: +0.32 / +55.2%. Annual fuel cost depends on regional gas/fuel tariffs and fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" d). Closest certified alternative is Friedrich 12PROG 40-50P FD HE EC3 (0.9 UEF).

- **Uniform Energy Factor**: 0.9 UEF

- **Cohort UEF Rank**: #1 of 71

- **First Hour Rating**: 88 gal

- **Storage Volume**: 40 gal

- **Fuel / Type**: Natural Gas / Gas Storage

- **DOE 2029 Rule Status**: Pass: +0.32 / +55.2%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Gas Storage UEF Efficiency Distribution (71 Certified Units). Highlighted pin shows Richmond 9GUH40-50FN relative to the cohort median.

Efficiency comparison & rule summary

Tested at 0.9 UEF, Richmond 9GUH40-50FN places #1 of 71 across 71 certified Gas Storage configurations (At 0.90 UEF median).

Richmond 9guh40-50fn stores 40 gal nominal; 88 gal first hour rating (-7 gal vs. 95 gal median); fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" d).

Closest alternatives to Richmond 9GUH40-50FN include Friedrich 12PROG 40-50P FD HE EC3 (0.9 UEF, at parity) alongside Rheem ECE G40-50U CN HE* (0.9 UEF, at parity).

## How Do Richmond 9GUH40-50FN Specs Compare to Gas Storage Medians?

Richmond 9GUH40-50FN places #1 of 71 across 71 certified Gas Storage configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 71 ENERGY STAR Gas Storage peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Richmond](https://gcsradheat.com/brands/richmond/) | 80 certified listings | ENERGY STAR PD 3387616 |
| Model Number | 9GUH40-50FN | Draw pattern: High-Usage | 9GUH40-50FN |
| Uniform Energy Factor (UEF) | 0.9 | At 0.90 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 88 gal | -7 gal vs. 95 gal median | 10 CFR 430 Recovery Test |
| Thermal Recovery Efficiency | 97% | +3.0 pts vs. 94.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 54.5" H x 21.8" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 7 A max | 120V AC ignition/fan + gas piping check | NEC / Branch circuit check |
| Certification Date | 2024-11-04 | Certified 2024-11-04 | Markets: United States |

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Are There Active CPSC Safety Recalls for Richmond Water Heaters?

Zero active CPSC recalls matched Richmond in our 2026-11-23 SaferProducts sweep; verify your individual tank date code via our lookup tool. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## Which Certified Water Heaters Match 9GUH40-50FN Most Closely?

These 5 competing Gas Storage units sit nearest to Richmond 9GUH40-50FN by storage capacity and 0.9 UEF rating.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Friedrich 12PROG 40-50P FD HE EC3](https://gcsradheat.com/water-heaters/friedrich/12prog-40-50p-fd-he-ec3/) | Gas Storage | 40 gal | 88 gal | 0.9 (at parity) | — |
| [Rheem ECE G40-50U CN HE*](https://gcsradheat.com/water-heaters/rheem/ece-g40-50u-cn-he/) | Gas Storage | 40 gal | 88 gal | 0.9 (at parity) | — |
| [Ruud PRO+G40-50P RU HE EC1](https://gcsradheat.com/water-heaters/ruud/pro-g40-50p-ru-he-ec1/) | Gas Storage | 40 gal | 88 gal | 0.9 (at parity) | — |
| [A. O. Smith GC6-PS4050*V 1**](https://gcsradheat.com/water-heaters/a-o-smith/gc6-ps4050-v-1/) | Gas Storage | 38 gal | 86 gal | 0.9 (at parity) | — |
| [Friedrich 12PROG 40-50U FD HE EC3](https://gcsradheat.com/water-heaters/friedrich/12prog-40-50u-fd-he-ec3/) | Gas Storage | 40 gal | 88 gal | 0.9 (at parity) | — |

## What Installation Caveats Apply Before Buying Richmond 9GUH40-50FN?

Even high-UEF units like Richmond 9GUH40-50FN (0.9 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

### Key Limitations & Exclusions

- Richmond 9GUH40-50FN logs 0.9 UEF (Pass: +0.32 / +55.2%); check May 6, 2029 10 CFR 430.32 transition status.
- Drain tank sediment yearly and inspect Richmond 9GUH40-50FN's sacrificial anode rod every 4–6 years.
- Peak simultaneous draws exceeding 88 gal will deplete stored recovery capacity.

### Which Option Fits Your Situation?

**Direct Footprint Replacement for Richmond 9GUH40-50FN** Strong Fit — Matches existing plumbing and vent clearances.

**2026 Post-OBBBA Rebate Buyers** Verify Tier — DOE HEAR ($1,750 max) targets >=2.30 UEF heat pump models like Friedrich 12PROG 40-50P FD HE EC3.

**Very Hard Well Water (>10.5 GPG)** Add Softener / Flush — Schedule 6-month tank sediment drains.

## What Are the Key Questions About Richmond 9GUH40-50FN?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Is Richmond 9GUH40-50FN eligible for continued manufacture past May 6, 2029?

At 0.9 UEF, Richmond 9GUH40-50FN achieves Pass: +0.32 / +55.2% for the 2029 DOE standard and stands #1 of 71 against Friedrich 12PROG 40-50P FD HE EC3 and Rheem ECE G40-50U CN HE*.

### How tall and wide is Richmond 9GUH40-50FN, and what service clearance is needed?

Physical dimensions for Richmond 9GUH40-50FN are 54.5 in. height and 21.8 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" d)); verify stair turns and drain pan width before delivery.

### Will Richmond 9GUH40-50FN require upgrading household electrical panels or gas piping?

Check Natural Gas piping and venting for Richmond 9GUH40-50FN (120V AC ignition/fan + gas piping check); undersized 1/2 in. gas branches cause peak-demand ignition lockouts on high-input burners.

### Is Richmond 9GUH40-50FN economical to operate at 18.16 cents/kWh US electric rates?

Fuel bills for Richmond 9GUH40-50FN (Natural Gas, 0.9 UEF) hinge on household gallon demand and local gas utility tariffs compared with Friedrich 12PROG 40-50P FD HE EC3.

### Which installation bottlenecks limit Richmond 9GUH40-50FN?

Check local 10 CFR 430.32(d)(2) phase-in timing (Pass: +0.32 / +55.2%) and physical doorway clearances before choosing Richmond 9GUH40-50FN over Friedrich 12PROG 40-50P FD HE EC3.

### How does Richmond 9GUH40-50FN handle simultaneous showers and laundry?

Delivering 88 gal in the first hour (-7 gal vs. 95 gal median), Richmond 9GUH40-50FN combines 40 gal tank storage with rapid burner/element recovery.

### How long is the warranty on Richmond 9GUH40-50FN and how do you decode its serial?

CPSC records show 0 active plumbing recalls for Richmond as of 2026-11-23. Confirm install proof and serial manufacture year on Richmond 9GUH40-50FN before calling service.

### How do 2026 post-OBBBA rebates affect buying Richmond 9GUH40-50FN?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Gas Storage is Friedrich 12PROG 40-50P FD HE EC3 (0.9 UEF).

## Which Sizing and Compliance Guides Pair with 9GUH40-50FN?

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Friedrich 12PROG 40-50P FD HE EC3 (0.9 UEF)→](https://gcsradheat.com/water-heaters/friedrich/12prog-40-50p-fd-he-ec3/)
- [Compare Rheem ECE G40-50U CN HE* (0.9 UEF)→](https://gcsradheat.com/water-heaters/rheem/ece-g40-50u-cn-he/)
- [View All Richmond Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/richmond/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm gas pipe length and CFH capacity (especially 199,000 BTU/h condensing tankless conversions under IFGC Table 402.4) and decode the old unit's serial plate.
[Verify Gas Line (IFGC)](https://gcsradheat.com/tools/gas-pipe-sizing-calculator/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)