title: "Rinnai REHP80C (4 UEF, 75 gal) — TapAndPipe"
url: https://gcsradheat.com/water-heaters/rinnai/rehp80c/
description: "In the 706-unit Hybrid/Electric Heat Pump class, Rinnai REHP80C (Electric) achieves a certified 4.0 UEF rating across its 75-gallon nominal tank, 91 gal First."
---

ENERGY STAR water heater model · PD 3531244

# Rinnai REHP80C Water Heater Specifications (4 UEF)

In the 706-unit Hybrid/Electric Heat Pump class, Rinnai REHP80C (Electric) achieves a certified 4.0 UEF rating across its 75-gallon nominal tank, 91 gal First Hour Rating (rank #106 of 706, PD 3531244) and verifies as Pass: +1.50 / +60.0% for 2029 DOE floors. Rated annual electricity draw of 1,225 kWh/yr equates to roughly $222/yr ($2,225 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Midea CAN3-RSJ-15/300RDVN3-L4 (4.0 UEF).

- **Uniform Energy Factor**: 4.0 UEF

- **Cohort UEF Rank**: #106 of 706 (top 19.8%)

- **First Hour Rating**: 91 gal

- **Storage Volume**: 75 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.50 / +60.0%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Rinnai REHP80C relative to the cohort median.

Efficiency comparison & rule summary

Rinnai REHP80C records 4.0 UEF efficiency, putting it #106 of 706 among 706 Hybrid/Electric Heat Pump peers.

10 CFR 430.32(d)(2) compliance: Rinnai REHP80C exceeds 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +1.50 UEF (+60.0%). At EIA August 2026 national rates (18.16 cents/kWh), 1,225 kWh/yr for Rinnai REHP80C runs ~$222/yr vs. ~$967/yr for a 0.92 UEF electric tank. Acoustic output is 49 dBA (quieter than 12.8% of Hybrid/Electric Heat Pump models).

State electric sensitivity for Rinnai REHP80C: 10-year operating spend spans $1,792 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,780 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Competing options beside Rinnai REHP80C (4.0 UEF) are Midea CAN3-RSJ-15/300RDVN3-L4 (4.0 UEF, at parity) and Bradford White RE2HP80**-1NCTT (4.0 UEF, at parity).

## How Complete Are the Certified Metrics for Rinnai REHP80C?

Standing at #106 of 706 (top 19.8%) among 706 certified Hybrid/Electric Heat Pump heaters, Rinnai REHP80C brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Rinnai](https://gcsradheat.com/brands/rinnai/) | 25 certified listings | ENERGY STAR PD 3531244 |
| Model Number | REHP80C | Draw pattern: High-Usage | REHP80C |
| Uniform Energy Factor (UEF) | 4.0 | +0.30 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 91 gal | +19 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,225 kWh/yr | +153 kWh/yr vs. 1,072 kWh/yr median | Est. $222/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 454% | +25.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 74.2" H x 25.7" D | Needs >72 in. overhead clearance; clears 28 in. utility doorway (25.7" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 24 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Sound Pressure Level | 49 dBA | quieter than 12.8% of Hybrid/Electric Heat Pump models · At 49 dBA median | Indoor placement check |
| Certification Date | 2026-03-24 | Certified 2026-03-24 | Markets: United States, Canada |

## What Is the Projected Utility Bill for REHP80C by State?

At 1,225 kWh/yr, Rinnai REHP80C averages about $222/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $222/yr | $2,225 | $7,447 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $578/yr | $5,780 | $19,349 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $364/yr | $3,644 | $12,200 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $195/yr | $1,949 | $6,525 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $179/yr | $1,792 | $6,000 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (1,225 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Are Rinnai Models Affected by Current CPSC Notices?

Zero brand-level CPSC hazard notices matched Rinnai in our 2026-11-23 feed; decode your water heater's serial number below to confirm warranty status. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## Which 5 Models Offer Similar Output to REHP80C?

Ordered by minimal capacity and UEF spread relative to Rinnai REHP80C, these five certified peers give direct replacement benchmarks.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Midea CAN3-RSJ-15/300RDVN3-L4](https://gcsradheat.com/water-heaters/midea/can3-rsj-15-300rdvn3-l4/) | Hybrid/Electric Heat Pump | 75 gal | 91 gal | 4.0 (at parity) | 1,230 |
| [Bradford White RE2HP80**-1NCTT](https://gcsradheat.com/water-heaters/bradford-white/re2hp80-1nctt/) | Hybrid/Electric Heat Pump | 75 gal | 88 gal | 4.0 (at parity) | 1,240 |
| [JETGLAS RE2HP80*-1NCTT](https://gcsradheat.com/water-heaters/jetglas/re2hp80-1nctt/) | Hybrid/Electric Heat Pump | 75 gal | 88 gal | 4.0 (at parity) | 1,240 |
| [1HVAC ACIQ-80G-HP-WH](https://gcsradheat.com/water-heaters/1hvac/aciq-80g-hp-wh/) | Hybrid/Electric Heat Pump | 74 gal | 91 gal | 4.0 (at parity) | 1,240 |
| [Midea MAHW-80VN3B](https://gcsradheat.com/water-heaters/midea/mahw-80vn3b/) | Hybrid/Electric Heat Pump | 75 gal | 91 gal | 4.0 (at parity) | 1,230 |

## When Should Homeowners Skip Rinnai REHP80C (Hybrid/Electric Heat Pump)?

Check Rinnai REHP80C's mechanical constraints—including utility space, Electric capacity, and Pass: +1.50 / +60.0% status—against typical residential installations.

### Key Limitations & Exclusions

- Rinnai REHP80C needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Rinnai REHP80C directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing Rinnai REHP80C** Strong Fit — 4.0 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare Midea CAN3-RSJ-15/300RDVN3-L4 footprint.

## Practical Specs & Code Questions for Rinnai REHP80C

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Will Rinnai REHP80C stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 4.0 UEF, Rinnai REHP80C shows Pass: +1.50 / +60.0% relative to May 6, 2029 federal DOE limits while placing #106 of 706 (top 19.8%) among 706 Hybrid/Electric Heat Pump peers like Midea CAN3-RSJ-15/300RDVN3-L4.

### Will Rinnai REHP80C fit through a standard utility door and 72-inch basement ceiling?

Measuring 74.2 in. tall by 25.7 in. diameter, Rinnai REHP80C notes: needs >72 in. overhead clearance; clears 28 in. utility doorway (25.7" d). Reserve space above the jacket for T&P piping and anode removal.

### Do existing utility hookups support Rinnai REHP80C during replacement?

Electrical specs for Rinnai REHP80C call for 240V at 24A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.

### What is the estimated 10-year operating spend for Rinnai REHP80C?

At 18.16 cents/kWh national residential pricing, Rinnai REHP80C's 1,225 kWh/yr draw equals roughly $222 annually or $2,220 across a 10-year horizon (ranging from $179/yr in Washington hydro tiers up to $578/yr in Hawaii).

### When is Rinnai REHP80C a poor fit for a residential replacement?

Avoid placing Rinnai REHP80C directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.

### What First Hour Rating or flow capacity does Rinnai REHP80C deliver?

With 91 gal FHR (+19 gal vs. 72 gal median), Rinnai REHP80C fits larger 3–5 person homes cleanly.

### How do you verify manufacturing age and recall status on Rinnai REHP80C?

Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for Rinnai; verify exact manufacturing week for Rinnai REHP80C using the Serial Number Lookup tool.

### Does Rinnai REHP80C qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Rinnai REHP80C. Closest peer in Hybrid/Electric Heat Pump is Midea CAN3-RSJ-15/300RDVN3-L4 (4.0 UEF).

## Installation, Serial & DOE 2029 Links for REHP80C

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Midea CAN3-RSJ-15/300RDVN3-L4 (4.0 UEF)→](https://gcsradheat.com/water-heaters/midea/can3-rsj-15-300rdvn3-l4/)
- [Compare Bradford White RE2HP80**-1NCTT (4.0 UEF)→](https://gcsradheat.com/water-heaters/bradford-white/re2hp80-1nctt/)
- [View All Rinnai Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/rinnai/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)