title: "Rinnai REHP80CW (4 UEF, 75 gal) — TapAndPipe"
url: https://gcsradheat.com/water-heaters/rinnai/rehp80cw/
description: "In the 706-unit Hybrid/Electric Heat Pump class, Rinnai REHP80CW (Electric) achieves a certified 4.0 UEF rating across its 75-gallon nominal tank, 91 gal First."
---

ENERGY STAR water heater model · PD 4682174

# Rinnai REHP80CW Water Heater Specifications (4 UEF)

In the 706-unit Hybrid/Electric Heat Pump class, Rinnai REHP80CW (Electric) achieves a certified 4.0 UEF rating across its 75-gallon nominal tank, 91 gal First Hour Rating (rank #106 of 706, PD 4682174) and verifies as Pass: +1.50 / +60.0% for 2029 DOE floors. Rated annual electricity draw of 1,230 kWh/yr equates to roughly $223/yr ($2,234 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Midea CAN3-RSJ-15/300RDVN3-L4 (4.0 UEF).

- **Uniform Energy Factor**: 4.0 UEF

- **Cohort UEF Rank**: #106 of 706 (top 19.8%)

- **First Hour Rating**: 91 gal

- **Storage Volume**: 75 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.50 / +60.0%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Rinnai REHP80CW relative to the cohort median.

Efficiency comparison & rule summary

Rinnai REHP80CW records 4.0 UEF efficiency, putting it #106 of 706 among 706 Hybrid/Electric Heat Pump peers.

10 CFR 430.32(d)(2) compliance: Rinnai REHP80CW exceeds 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +1.50 UEF (+60.0%). At EIA August 2026 national rates (18.16 cents/kWh), 1,230 kWh/yr for Rinnai REHP80CW runs ~$223/yr vs. ~$971/yr for a 0.92 UEF electric tank. Acoustic output is 49 dBA (quieter than 12.8% of Hybrid/Electric Heat Pump models).

State electric sensitivity for Rinnai REHP80CW: 10-year operating spend spans $1,799 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,803 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Competing options beside Rinnai REHP80CW (4.0 UEF) are Midea CAN3-RSJ-15/300RDVN3-L4 (4.0 UEF, at parity) and Bradford White RE2HP80**-1NCTT (4.0 UEF, at parity).

## How Do Rinnai REHP80CW Specs Compare to Hybrid/Electric Heat Pump Medians?

Rinnai REHP80CW places #106 of 706 (top 19.8%) across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Rinnai](https://gcsradheat.com/brands/rinnai/) | 25 certified listings | ENERGY STAR PD 4682174 |
| Model Number | REHP80CW | Draw pattern: High-Usage | REHP80CW |
| Uniform Energy Factor (UEF) | 4.0 | +0.30 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 91 gal | +19 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,230 kWh/yr | +158 kWh/yr vs. 1,072 kWh/yr median | Est. $223/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 450% | +21.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 41.7" H x 21.8" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 24 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Sound Pressure Level | 49 dBA | quieter than 12.8% of Hybrid/Electric Heat Pump models · At 49 dBA median | Indoor placement check |
| Certification Date | 2026-07-31 | Certified 2026-07-31 | Markets: United States, Canada |

## What Does REHP80CW Cost to Operate Across State Electricity Rates?

At 1,230 kWh/yr, Rinnai REHP80CW runs roughly $223/yr on the EIA national average tier under August 2026 Table 5.6.A rates.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $223/yr | $2,234 | $7,478 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $580/yr | $5,803 | $19,429 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $366/yr | $3,659 | $12,251 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $196/yr | $1,957 | $6,552 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $180/yr | $1,799 | $6,025 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (1,230 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Are There Active CPSC Safety Recalls for Rinnai Water Heaters?

Zero active CPSC recalls matched Rinnai in our 2026-11-23 SaferProducts sweep; verify your individual tank date code via our lookup tool. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## Which Certified Water Heaters Match REHP80CW Most Closely?

These 5 competing Hybrid/Electric Heat Pump units sit nearest to Rinnai REHP80CW by storage capacity and 4.0 UEF rating.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Midea CAN3-RSJ-15/300RDVN3-L4](https://gcsradheat.com/water-heaters/midea/can3-rsj-15-300rdvn3-l4/) | Hybrid/Electric Heat Pump | 75 gal | 91 gal | 4.0 (at parity) | 1,230 |
| [Bradford White RE2HP80**-1NCTT](https://gcsradheat.com/water-heaters/bradford-white/re2hp80-1nctt/) | Hybrid/Electric Heat Pump | 75 gal | 88 gal | 4.0 (at parity) | 1,240 |
| [JETGLAS RE2HP80*-1NCTT](https://gcsradheat.com/water-heaters/jetglas/re2hp80-1nctt/) | Hybrid/Electric Heat Pump | 75 gal | 88 gal | 4.0 (at parity) | 1,240 |
| [1HVAC ACIQ-80G-HP-WH](https://gcsradheat.com/water-heaters/1hvac/aciq-80g-hp-wh/) | Hybrid/Electric Heat Pump | 74 gal | 91 gal | 4.0 (at parity) | 1,240 |
| [Midea MAHW-80VN3B](https://gcsradheat.com/water-heaters/midea/mahw-80vn3b/) | Hybrid/Electric Heat Pump | 75 gal | 91 gal | 4.0 (at parity) | 1,230 |

## Which Home Setups Are NOT a Fit for Rinnai REHP80CW?

Comparing Rinnai REHP80CW against Midea CAN3-RSJ-15/300RDVN3-L4 requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

### Key Limitations & Exclusions

- Rinnai REHP80CW needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Rinnai REHP80CW directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing Rinnai REHP80CW** Strong Fit — 4.0 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare Midea CAN3-RSJ-15/300RDVN3-L4 footprint.

## What Are the Key Questions About Rinnai REHP80CW?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### How does Rinnai REHP80CW score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; Rinnai REHP80CW logs 4.0 UEF (Pass: +1.50 / +60.0%) within the 706-unit Hybrid/Electric Heat Pump group.

### What physical clearance dimensions apply when installing Rinnai REHP80CW?

With a 41.7 in. height and 21.8 in. diameter, Rinnai REHP80CW fits spaces matching: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" d), plus 6–12 in. above for plumbing shutoffs.

### What 240V circuit or IFGC fuel line capacity fits Rinnai REHP80CW?

Powered via 240V at 24A max, Rinnai REHP80CW requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.

### How do state electricity prices change annual costs for Rinnai REHP80CW?

Annual electric spend for Rinnai REHP80CW (1,230 kWh/yr) averages $223/yr nationwide (ranging from $180/yr in Washington hydro tiers up to $580/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.

### What homeowner setups should avoid choosing Rinnai REHP80CW?

Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on Rinnai REHP80CW.

### Is Rinnai REHP80CW sized adequately for a 2-to-4-person household?

ENERGY STAR certifies Rinnai REHP80CW at 91 gal First Hour Rating (+19 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.

### Does Rinnai have active CPSC SaferProducts notices affecting REHP80CW?

Zero CPSC recall alerts matched Rinnai (2026-11-23 check). Keep your Rinnai REHP80CW serial code handy to track standard 6-to-12-year OEM warranty coverage.

### Which competing water heater matches Rinnai REHP80CW (4.0 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for Rinnai REHP80CW. Closest peer in Hybrid/Electric Heat Pump is Midea CAN3-RSJ-15/300RDVN3-L4 (4.0 UEF).

## Which Sizing and Compliance Guides Pair with REHP80CW?

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Midea CAN3-RSJ-15/300RDVN3-L4 (4.0 UEF)→](https://gcsradheat.com/water-heaters/midea/can3-rsj-15-300rdvn3-l4/)
- [Compare Bradford White RE2HP80**-1NCTT (4.0 UEF)→](https://gcsradheat.com/water-heaters/bradford-white/re2hp80-1nctt/)
- [View All Rinnai Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/rinnai/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)