---
title: "Ruud CPROPH65 T2 CD375-SO (4.05 UEF, 59 gal)"
url: https://gcsradheat.com/water-heaters/ruud/cproph65-t2-cd375-so/
description: "With PD 4518083 certification, Ruud CPROPH65 T2 CD375-SO (Hybrid/Electric Heat Pump, Electric) achieves a certified 4.05 UEF rating across its 59-gallon."
---

ENERGY STAR water heater model · PD 4518083

# Ruud CPROPH65 T2 CD375-SO Water Heater Specifications (4.05 UEF)

With PD 4518083 certification, Ruud CPROPH65 T2 CD375-SO (Hybrid/Electric Heat Pump, Electric) achieves a certified 4.05 UEF rating across its 59-gallon nominal tank, 75 gal First Hour Rating, standing #61 of 706 across 706 peers with Pass: +1.55 / +62.0% for May 6, 2029. Rated annual electricity draw of 1,213 kWh/yr equates to roughly $220/yr ($2,203 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH65 T2 FD400-30 (4.05 UEF).

- **Uniform Energy Factor**: 4.05 UEF

- **Cohort UEF Rank**: #61 of 706 (top 14.2%)

- **First Hour Rating**: 75 gal

- **Storage Volume**: 59 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.55 / +62.0%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Ruud CPROPH65 T2 CD375-SO relative to the cohort median.

Efficiency comparison & rule summary

ENERGY STAR certification places Ruud CPROPH65 T2 CD375-SO at 4.05 UEF (#61 of 706; +0.35 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.

May 6, 2029 readiness: Ruud CPROPH65 T2 CD375-SO stands +1.55 UEF (+62.0%) relative to 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,213 kWh/yr for Ruud CPROPH65 T2 CD375-SO runs ~$220/yr vs. ~$970/yr for a 0.92 UEF electric tank.

State electric sensitivity for Ruud CPROPH65 T2 CD375-SO: 10-year operating spend spans $1,775 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,723 in Hawaii (Highest EIA State) (47.18 cents/kWh).

In the Hybrid/Electric Heat Pump tier, Friedrich PROH65 T2 FD400-30 (4.05 UEF, at parity) and Rheem CPROPH65 T2 RH375-SO (4.05 UEF, at parity) bracket Ruud CPROPH65 T2 CD375-SO.

## Which Specs Set Ruud CPROPH65 T2 CD375-SO Apart From Cohort Averages?

Ranked #61 of 706 (top 14.2%) inside the 706-model Hybrid/Electric Heat Pump cohort, Ruud CPROPH65 T2 CD375-SO is evaluated row by row below against category medians.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Ruud](https://gcsradheat.com/brands/ruud/) | 95 certified listings | ENERGY STAR PD 4518083 |
| Model Number | CPROPH65 T2 CD375-SO | Draw pattern: High-Usage | CPROPH65 T2 CD375-SO |
| Uniform Energy Factor (UEF) | 4.05 | +0.35 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 75 gal | +3 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,213 kWh/yr | +141 kWh/yr vs. 1,072 kWh/yr median | Est. $220/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 457% | +28.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 74.2" H x 24.3" D | Needs >72 in. overhead clearance; clears 28 in. utility doorway (24.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-15 | Certified 2026-10-15 | Markets: Canada |

## How Do Regional kWh Prices Impact CPROPH65 T2 CD375-SO Over 10 Years?

Using EIA Table 5.6.A benchmarks, Ruud CPROPH65 T2 CD375-SO's 1,213 kWh/yr draw translates to roughly $220/yr on typical US residential bills.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $220/yr | $2,203 | $7,495 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $572/yr | $5,723 | $19,471 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $361/yr | $3,609 | $12,278 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $193/yr | $1,930 | $6,566 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $177/yr | $1,775 | $6,038 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (1,213 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## What Should Ruud Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC SaferProducts snapshot includes 2 filings tied to Ruud; verify whether your CPROPH65 T2 CD375-SO production run falls inside affected ranges. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

**2 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range**

- **Recall #07108 (2007-02-21):** Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard ([CPSC Notice](https://www.cpsc.gov/Recalls/2007/Tankless-Water-Heaters-Recalled-for-Repair-Due-to-Carbon-Monoxide-Poisoning-Hazard))
- **Recall #05274 (2005-09-16):** CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters ([CPSC Notice](https://www.cpsc.gov/Recalls/2005/CPSC-Robertshaw-Controls-Co-Announce-Recall-of-Gas-Control-Valves-on-Water-Heaters-))

## How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?

Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Friedrich PROH65 T2 FD400-30](https://gcsradheat.com/water-heaters/friedrich/proh65-t2-fd400-30/) | Hybrid/Electric Heat Pump | 59 gal | 75 gal | 4.05 (at parity) | 1,184 |
| [Rheem CPROPH65 T2 RH375-SO](https://gcsradheat.com/water-heaters/rheem/cproph65-t2-rh375-so/) | Hybrid/Electric Heat Pump | 59 gal | 75 gal | 4.05 (at parity) | 1,184 |
| [Richmond 10CE65-HP5S30](https://gcsradheat.com/water-heaters/richmond/10ce65-hp5s30/) | Hybrid/Electric Heat Pump | 59 gal | 75 gal | 4.05 (at parity) | 1,289 |
| [Bosch TR7000T-65CA](https://gcsradheat.com/water-heaters/bosch/tr7000t-65ca/) | Hybrid/Electric Heat Pump | 60 gal | 80 gal | 3.9 (-0.15) | 1,240 |
| [Friedrich PROH65 T2 FD400-SO](https://gcsradheat.com/water-heaters/friedrich/proh65-t2-fd400-so/) | Hybrid/Electric Heat Pump | 59 gal | 75 gal | 4.05 (at parity) | 1,184 |

## What Installation Caveats Apply Before Buying Ruud CPROPH65 T2 CD375-SO?

Even high-UEF units like Ruud CPROPH65 T2 CD375-SO (4.05 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

### Key Limitations & Exclusions

- Ruud CPROPH65 T2 CD375-SO needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Ruud CPROPH65 T2 CD375-SO directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing Ruud CPROPH65 T2 CD375-SO** Strong Fit — 4.05 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare Friedrich PROH65 T2 FD400-30 footprint.

## Frequently Asked Technical Questions: Ruud CPROPH65 T2 CD375-SO

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Is Ruud CPROPH65 T2 CD375-SO eligible for continued manufacture past May 6, 2029?

At 4.05 UEF, Ruud CPROPH65 T2 CD375-SO achieves Pass: +1.55 / +62.0% for the 2029 DOE standard and stands #61 of 706 (top 14.2%) against Friedrich PROH65 T2 FD400-30 and Rheem CPROPH65 T2 RH375-SO.

### How tall and wide is Ruud CPROPH65 T2 CD375-SO, and what service clearance is needed?

Physical dimensions for Ruud CPROPH65 T2 CD375-SO are 74.2 in. height and 24.3 in. diameter (needs >72 in. overhead clearance; clears 28 in. utility doorway (24.3" d)); verify stair turns and drain pan width before delivery.

### Will Ruud CPROPH65 T2 CD375-SO require upgrading household electrical panels or gas piping?

Ruud CPROPH65 T2 CD375-SO draws 240V at 21A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.

### Is Ruud CPROPH65 T2 CD375-SO economical to operate at 18.16 cents/kWh US electric rates?

Expect roughly $220/yr ($2,200 over 10 years) to power Ruud CPROPH65 T2 CD375-SO at 1,213 kWh/yr under the 18.16 cents/kWh US average (ranging from $177/yr in Washington hydro tiers up to $572/yr in Hawaii).

### Which installation bottlenecks limit Ruud CPROPH65 T2 CD375-SO?

If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, Ruud CPROPH65 T2 CD375-SO drops into resistance mode more often.

### How does Ruud CPROPH65 T2 CD375-SO handle simultaneous showers and laundry?

Delivering 75 gal in the first hour (+3 gal vs. 72 gal median), Ruud CPROPH65 T2 CD375-SO combines 59 gal tank storage with rapid burner/element recovery.

### How long is the warranty on Ruud CPROPH65 T2 CD375-SO and how do you decode its serial?

CPSC SaferProducts records show 2 brand-level recall notices mentioning Ruud as of 2026-11-23, including #07108 (2007-02-21). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

### How do 2026 post-OBBBA rebates affect buying Ruud CPROPH65 T2 CD375-SO?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH65 T2 FD400-30 (4.05 UEF).

## Essential Pre-Install Guides for Ruud CPROPH65 T2 CD375-SO

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Friedrich PROH65 T2 FD400-30 (4.05 UEF)→](https://gcsradheat.com/water-heaters/friedrich/proh65-t2-fd400-30/)
- [Compare Rheem CPROPH65 T2 RH375-SO (4.05 UEF)→](https://gcsradheat.com/water-heaters/rheem/cproph65-t2-rh375-so/)
- [View All Ruud Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/ruud/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)
