title: "Ruud PRO+G40-50P RU HE EC1 (0.9 UEF, 40 gal)"
url: https://gcsradheat.com/water-heaters/ruud/pro-g40-50p-ru-he-ec1/
description: "The Ruud PRO+G40-50P RU HE EC1 (Gas Storage, Propane) achieves a certified 0.9 UEF rating across its 40-gallon nominal tank, 88 gal First Hour Rating, ranking."
---

ENERGY STAR water heater model · PD 3387615

# Ruud PRO+G40-50P RU HE EC1 Water Heater Specifications (0.9 UEF)

The Ruud PRO+G40-50P RU HE EC1 (Gas Storage, Propane) achieves a certified 0.9 UEF rating across its 40-gallon nominal tank, 88 gal First Hour Rating, ranking #1 of 71 among 71 ENERGY STAR Gas Storage models (PD 3387615). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +0.32 / +55.2%. Annual fuel cost depends on regional gas/fuel tariffs and fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" d). Closest certified alternative is Friedrich 12PROG 40-50P FD HE EC3 (0.9 UEF).

- **Uniform Energy Factor**: 0.9 UEF

- **Cohort UEF Rank**: #1 of 71

- **First Hour Rating**: 88 gal

- **Storage Volume**: 40 gal

- **Fuel / Type**: Propane / Gas Storage

- **DOE 2029 Rule Status**: Pass: +0.32 / +55.2%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Gas Storage UEF Efficiency Distribution (71 Certified Units). Highlighted pin shows Ruud PRO+G40-50P RU HE EC1 relative to the cohort median.

Efficiency comparison & rule summary

Ruud PRO+G40-50P RU HE EC1 (0.9 UEF) ranks #1 of 71 Gas Storage models — 51-way tie; more efficient than 28.2% of Gas Storage models, at the 0.90 UEF median.

Ruud pro+g40-50p ru he ec1 stores 40 gal nominal; 88 gal first hour rating (-7 gal vs. 95 gal median); fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" d).

Peer comparison: Ruud PRO+G40-50P RU HE EC1 (0.9 UEF) compares closely with Friedrich 12PROG 40-50P FD HE EC3 (0.9 UEF, at parity) and Rheem ECE G40-50U CN HE* (0.9 UEF, at parity).

## Which Specs Set Ruud PRO+G40-50P RU HE EC1 Apart From Cohort Averages?

Ranked #1 of 71 inside the 71-model Gas Storage cohort, Ruud PRO+G40-50P RU HE EC1 is evaluated row by row below against category medians.

Certified model attributes compared against 71 ENERGY STAR Gas Storage peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Ruud](https://gcsradheat.com/brands/ruud/) | 95 certified listings | ENERGY STAR PD 3387615 |
| Model Number | PRO+G40-50P RU HE EC1 | Draw pattern: High-Usage | PRO+G40-50P RU HE EC1 |
| Uniform Energy Factor (UEF) | 0.9 | At 0.90 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 88 gal | -7 gal vs. 95 gal median | 10 CFR 430 Recovery Test |
| Thermal Recovery Efficiency | 97% | +3.0 pts vs. 94.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 54.5" H x 21.8" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 7 A max | 120V AC ignition/fan + gas piping check | NEC / Branch circuit check |
| Certification Date | 2024-11-04 | Certified 2024-11-04 | Markets: United States |

## What Should Ruud Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC SaferProducts snapshot includes 2 filings tied to Ruud; verify whether your PRO+G40-50P RU HE EC1 production run falls inside affected ranges. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

**2 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range**

- **Recall #07108 (2007-02-21):** Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard ([CPSC Notice](https://www.cpsc.gov/Recalls/2007/Tankless-Water-Heaters-Recalled-for-Repair-Due-to-Carbon-Monoxide-Poisoning-Hazard))
- **Recall #05274 (2005-09-16):** CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters ([CPSC Notice](https://www.cpsc.gov/Recalls/2005/CPSC-Robertshaw-Controls-Co-Announce-Recall-of-Gas-Control-Valves-on-Water-Heaters-))

## How Do Five Nearby Gas Storage Models Stack Up?

Five alternative Gas Storage units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Friedrich 12PROG 40-50P FD HE EC3](https://gcsradheat.com/water-heaters/friedrich/12prog-40-50p-fd-he-ec3/) | Gas Storage | 40 gal | 88 gal | 0.9 (at parity) | — |
| [Rheem ECE G40-50U CN HE*](https://gcsradheat.com/water-heaters/rheem/ece-g40-50u-cn-he/) | Gas Storage | 40 gal | 88 gal | 0.9 (at parity) | — |
| [Richmond 12GUH40-50F*](https://gcsradheat.com/water-heaters/richmond/12guh40-50f/) | Gas Storage | 40 gal | 88 gal | 0.9 (at parity) | — |
| [A. O. Smith GC6-PS4050*V 1**](https://gcsradheat.com/water-heaters/a-o-smith/gc6-ps4050-v-1/) | Gas Storage | 38 gal | 86 gal | 0.9 (at parity) | — |
| [Friedrich 12PROG 40-50U FD HE EC3](https://gcsradheat.com/water-heaters/friedrich/12prog-40-50u-fd-he-ec3/) | Gas Storage | 40 gal | 88 gal | 0.9 (at parity) | — |

## What Installation Caveats Apply Before Buying Ruud PRO+G40-50P RU HE EC1?

Even high-UEF units like Ruud PRO+G40-50P RU HE EC1 (0.9 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

### Key Limitations & Exclusions

- Ruud PRO+G40-50P RU HE EC1 logs 0.9 UEF (Pass: +0.32 / +55.2%); check May 6, 2029 10 CFR 430.32 transition status.
- Drain tank sediment yearly and inspect Ruud PRO+G40-50P RU HE EC1's sacrificial anode rod every 4–6 years.
- Peak simultaneous draws exceeding 88 gal will deplete stored recovery capacity.

### Which Option Fits Your Situation?

**Direct Footprint Replacement for Ruud PRO+G40-50P RU HE EC1** Strong Fit — Matches existing plumbing and vent clearances.

**2026 Post-OBBBA Rebate Buyers** Verify Tier — DOE HEAR ($1,750 max) targets >=2.30 UEF heat pump models like Friedrich 12PROG 40-50P FD HE EC3.

**Very Hard Well Water (>10.5 GPG)** Add Softener / Flush — Schedule 6-month tank sediment drains.

## Frequently Asked Technical Questions: Ruud PRO+G40-50P RU HE EC1

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Is Ruud PRO+G40-50P RU HE EC1 eligible for continued manufacture past May 6, 2029?

At 0.9 UEF, Ruud PRO+G40-50P RU HE EC1 achieves Pass: +0.32 / +55.2% for the 2029 DOE standard and stands #1 of 71 against Friedrich 12PROG 40-50P FD HE EC3 and Rheem ECE G40-50U CN HE*.

### How tall and wide is Ruud PRO+G40-50P RU HE EC1, and what service clearance is needed?

Physical dimensions for Ruud PRO+G40-50P RU HE EC1 are 54.5 in. height and 21.8 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" d)); verify stair turns and drain pan width before delivery.

### Will Ruud PRO+G40-50P RU HE EC1 require upgrading household electrical panels or gas piping?

Check Propane piping and venting for Ruud PRO+G40-50P RU HE EC1 (120V AC ignition/fan + gas piping check); undersized 1/2 in. gas branches cause peak-demand ignition lockouts on high-input burners.

### Is Ruud PRO+G40-50P RU HE EC1 economical to operate at 18.16 cents/kWh US electric rates?

Fuel bills for Ruud PRO+G40-50P RU HE EC1 (Propane, 0.9 UEF) hinge on household gallon demand and local gas utility tariffs compared with Friedrich 12PROG 40-50P FD HE EC3.

### Which installation bottlenecks limit Ruud PRO+G40-50P RU HE EC1?

Check local 10 CFR 430.32(d)(2) phase-in timing (Pass: +0.32 / +55.2%) and physical doorway clearances before choosing Ruud PRO+G40-50P RU HE EC1 over Friedrich 12PROG 40-50P FD HE EC3.

### How does Ruud PRO+G40-50P RU HE EC1 handle simultaneous showers and laundry?

Delivering 88 gal in the first hour (-7 gal vs. 95 gal median), Ruud PRO+G40-50P RU HE EC1 combines 40 gal tank storage with rapid burner/element recovery.

### How long is the warranty on Ruud PRO+G40-50P RU HE EC1 and how do you decode its serial?

CPSC SaferProducts records show 2 brand-level recall notices mentioning Ruud as of 2026-11-23, including #07108 (2007-02-21). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

### How do 2026 post-OBBBA rebates affect buying Ruud PRO+G40-50P RU HE EC1?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Gas Storage is Friedrich 12PROG 40-50P FD HE EC3 (0.9 UEF).

## Essential Pre-Install Guides for Ruud PRO+G40-50P RU HE EC1

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Friedrich 12PROG 40-50P FD HE EC3 (0.9 UEF)→](https://gcsradheat.com/water-heaters/friedrich/12prog-40-50p-fd-he-ec3/)
- [Compare Rheem ECE G40-50U CN HE* (0.9 UEF)→](https://gcsradheat.com/water-heaters/rheem/ece-g40-50u-cn-he/)
- [View All Ruud Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/ruud/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm gas pipe length and CFH capacity (especially 199,000 BTU/h condensing tankless conversions under IFGC Table 402.4) and decode the old unit's serial plate.
[Verify Gas Line (IFGC)](https://gcsradheat.com/tools/gas-pipe-sizing-calculator/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)