description: "The Ruud PROUH40 T2 RU400-15 (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.45 UEF rating across its 36-gallon nominal tank, 46 gal First Hour."
---

ENERGY STAR water heater model · PD 3554170

# Ruud PROUH40 T2 RU400-15 Water Heater Specifications (3.45 UEF)

The Ruud PROUH40 T2 RU400-15 (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.45 UEF rating across its 36-gallon nominal tank, 46 gal First Hour Rating, ranking #563 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 3554170). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +1.15 / +50.0%. Rated annual electricity draw of 643 kWh/yr equates to roughly $117/yr ($1,168 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH40 T2 FD400-15 (3.45 UEF).

- **Uniform Energy Factor**: 3.45 UEF

- **Cohort UEF Rank**: #563 of 706

- **First Hour Rating**: 46 gal

- **Storage Volume**: 36 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.15 / +50.0%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Ruud PROUH40 T2 RU400-15 relative to the cohort median.

Efficiency comparison & rule summary

Ruud PROUH40 T2 RU400-15 (3.45 UEF) ranks #563 of 706 Hybrid/Electric Heat Pump models — 59-way tie; more efficient than 12% of Hybrid/Electric Heat Pump models, -0.25 UEF below the 3.70 UEF median.

Federal 2029 margin for Ruud PROUH40 T2 RU400-15: +1.15 UEF (+50.0%) vs. 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 643 kWh/yr for Ruud PROUH40 T2 RU400-15 runs ~$117/yr vs. ~$438/yr for a 0.92 UEF electric tank.

State electric sensitivity for Ruud PROUH40 T2 RU400-15: 10-year operating spend spans $941 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $3,034 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Peer comparison: Ruud PROUH40 T2 RU400-15 (3.45 UEF) compares closely with Friedrich PROH40 T2 FD400-15 (3.45 UEF, at parity) and Rheem CPROPH40 T2 RH400-15 (3.45 UEF, at parity).

## Which Specs Set Ruud PROUH40 T2 RU400-15 Apart From Cohort Averages?

Ranked #563 of 706 inside the 706-model Hybrid/Electric Heat Pump cohort, Ruud PROUH40 T2 RU400-15 is evaluated row by row below against category medians.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Ruud](https://gcsradheat.com/brands/ruud/) | 95 certified listings | ENERGY STAR PD 3554170 |
| Model Number | PROUH40 T2 RU400-15 | Draw pattern: Low-Usage | PROUH40 T2 RU400-15 |
| Uniform Energy Factor (UEF) | 3.45 | -0.25 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 46 gal | -26 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 643 kWh/yr | -429 kWh/yr vs. 1,072 kWh/yr median | Est. $117/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 432% | +3.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 62.3" H x 20.3" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 12 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-15 | Certified 2026-10-15 | Markets: United States |

## How Do Regional kWh Prices Impact PROUH40 T2 RU400-15 Over 10 Years?

Using EIA Table 5.6.A benchmarks, Ruud PROUH40 T2 RU400-15's 643 kWh/yr draw translates to roughly $117/yr on typical US residential bills.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $117/yr | $1,168 | $3,211 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $303/yr | $3,034 | $8,341 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $191/yr | $1,913 | $5,260 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $102/yr | $1,023 | $2,813 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $94/yr | $941 | $2,587 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (643 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## What Should Ruud Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC SaferProducts snapshot includes 2 filings tied to Ruud; verify whether your PROUH40 T2 RU400-15 production run falls inside affected ranges. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

**2 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range**

- **Recall #07108 (2007-02-21):** Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard ([CPSC Notice](https://www.cpsc.gov/Recalls/2007/Tankless-Water-Heaters-Recalled-for-Repair-Due-to-Carbon-Monoxide-Poisoning-Hazard))
- **Recall #05274 (2005-09-16):** CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters ([CPSC Notice](https://www.cpsc.gov/Recalls/2005/CPSC-Robertshaw-Controls-Co-Announce-Recall-of-Gas-Control-Valves-on-Water-Heaters-))

## How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?

Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Friedrich PROH40 T2 FD400-15](https://gcsradheat.com/water-heaters/friedrich/proh40-t2-fd400-15/) | Hybrid/Electric Heat Pump | 36 gal | 46 gal | 3.45 (at parity) | 643 |
| [Rheem CPROPH40 T2 RH400-15](https://gcsradheat.com/water-heaters/rheem/cproph40-t2-rh400-15/) | Hybrid/Electric Heat Pump | 36 gal | 46 gal | 3.45 (at parity) | 643 |
| [Richmond 10CE40-HP5U15](https://gcsradheat.com/water-heaters/richmond/10ce40-hp5u15/) | Hybrid/Electric Heat Pump | 36 gal | 46 gal | 3.45 (at parity) | 643 |
| [A. O. Smith CAHP-40 2**](https://gcsradheat.com/water-heaters/a-o-smith/cahp-40-2/) | Hybrid/Electric Heat Pump | 36 gal | 55 gal | 3.6 (+0.15) | 902 |
| [Rheem ECEPH40 T2 RH400-15](https://gcsradheat.com/water-heaters/rheem/eceph40-t2-rh400-15/) | Hybrid/Electric Heat Pump | 36 gal | 46 gal | 3.45 (at parity) | 643 |

## When Should Homeowners Skip Ruud PROUH40 T2 RU400-15 (Hybrid/Electric Heat Pump)?

Check Ruud PROUH40 T2 RU400-15's mechanical constraints—including utility space, Electric capacity, and Pass: +1.15 / +50.0% status—against typical residential installations.

### Key Limitations & Exclusions

- Ruud PROUH40 T2 RU400-15 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Ruud PROUH40 T2 RU400-15 directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing Ruud PROUH40 T2 RU400-15** Strong Fit — 3.45 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare Friedrich PROH40 T2 FD400-15 footprint.

## Frequently Asked Technical Questions: Ruud PROUH40 T2 RU400-15

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Will Ruud PROUH40 T2 RU400-15 stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 3.45 UEF, Ruud PROUH40 T2 RU400-15 shows Pass: +1.15 / +50.0% relative to May 6, 2029 federal DOE limits while placing #563 of 706 among 706 Hybrid/Electric Heat Pump peers like Friedrich PROH40 T2 FD400-15.

### Will Ruud PROUH40 T2 RU400-15 fit through a standard utility door and 72-inch basement ceiling?

Measuring 62.3 in. tall by 20.3 in. diameter, Ruud PROUH40 T2 RU400-15 notes: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" d). Reserve space above the jacket for T&P piping and anode removal.

### Do existing utility hookups support Ruud PROUH40 T2 RU400-15 during replacement?

Electrical specs for Ruud PROUH40 T2 RU400-15 call for 240V at 12A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.

### What is the estimated 10-year operating spend for Ruud PROUH40 T2 RU400-15?

At 18.16 cents/kWh national residential pricing, Ruud PROUH40 T2 RU400-15's 643 kWh/yr draw equals roughly $117 annually or $1,170 across a 10-year horizon (ranging from $94/yr in Washington hydro tiers up to $303/yr in Hawaii).

### When is Ruud PROUH40 T2 RU400-15 a poor fit for a residential replacement?

Avoid placing Ruud PROUH40 T2 RU400-15 directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.

### What First Hour Rating or flow capacity does Ruud PROUH40 T2 RU400-15 deliver?

With 46 gal FHR (-26 gal vs. 72 gal median), Ruud PROUH40 T2 RU400-15 fits 1–3 person or moderate-draw homes cleanly.

### How do you verify manufacturing age and recall status on Ruud PROUH40 T2 RU400-15?

CPSC SaferProducts records show 2 brand-level recall notices mentioning Ruud as of 2026-11-23, including #07108 (2007-02-21). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

### Does Ruud PROUH40 T2 RU400-15 qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Ruud PROUH40 T2 RU400-15. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH40 T2 FD400-15 (3.45 UEF).

## Essential Pre-Install Guides for Ruud PROUH40 T2 RU400-15

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Friedrich PROH40 T2 FD400-15 (3.45 UEF)→](https://gcsradheat.com/water-heaters/friedrich/proh40-t2-fd400-15/)
- [Compare Rheem CPROPH40 T2 RH400-15 (3.45 UEF)→](https://gcsradheat.com/water-heaters/rheem/cproph40-t2-rh400-15/)
- [View All Ruud Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/ruud/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)