title: "Ruud PROUH65 T2 RU350UM (3.5 UEF, 59 gal)"
url: https://gcsradheat.com/water-heaters/ruud/prouh65-t2-ru350um/
description: "Engineered as a Electric Hybrid/Electric Heat Pump unit, Ruud PROUH65 T2 RU350UM achieves a certified 3.5 UEF rating across its 59-gallon nominal tank, 75 gal."
---

ENERGY STAR water heater model · PD 3994187

# Ruud PROUH65 T2 RU350UM Water Heater Specifications (3.5 UEF)

Engineered as a Electric Hybrid/Electric Heat Pump unit, Ruud PROUH65 T2 RU350UM achieves a certified 3.5 UEF rating across its 59-gallon nominal tank, 75 gal First Hour Rating and ranks #481 of 706 in its 706-model cohort (PD 3994187), recording Pass: +1.00 / +40.0% under 2029 DOE rules. Rated annual electricity draw of 900 kWh/yr equates to roughly $163/yr ($1,634 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH65 T2 FD310BM (3.5 UEF).

- **Uniform Energy Factor**: 3.5 UEF

- **Cohort UEF Rank**: #481 of 706

- **First Hour Rating**: 75 gal

- **Storage Volume**: 59 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.00 / +40.0%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Ruud PROUH65 T2 RU350UM relative to the cohort median.

Efficiency comparison & rule summary

Within the 706-unit Hybrid/Electric Heat Pump cohort, Ruud PROUH65 T2 RU350UM logs 3.5 UEF and ranks #481 of 706.

Against 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF), Ruud PROUH65 T2 RU350UM holds a +1.00 UEF (+40.0%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 900 kWh/yr for Ruud PROUH65 T2 RU350UM runs ~$163/yr vs. ~$622/yr for a 0.92 UEF electric tank.

State electric sensitivity for Ruud PROUH65 T2 RU350UM: 10-year operating spend spans $1,317 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,246 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Cross-shopping Ruud PROUH65 T2 RU350UM (3.5 UEF)? Check Friedrich PROH65 T2 FD310BM (3.5 UEF, at parity) and Rheem CPRO H65 T2 RH310BM (3.5 UEF, at parity).

## Which Specs Set Ruud PROUH65 T2 RU350UM Apart From Cohort Averages?

Ranked #481 of 706 inside the 706-model Hybrid/Electric Heat Pump cohort, Ruud PROUH65 T2 RU350UM is evaluated row by row below against category medians.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Ruud](https://gcsradheat.com/brands/ruud/) | 95 certified listings | ENERGY STAR PD 3994187 |
| Model Number | PROUH65 T2 RU350UM | Draw pattern: High-Usage | PROUH65 T2 RU350UM |
| Uniform Energy Factor (UEF) | 3.5 | -0.20 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 75 gal | +3 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 900 kWh/yr | -172 kWh/yr vs. 1,072 kWh/yr median | Est. $163/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 409% | -20.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 64.2" H x 24.3" D | Verify 72 in. vertical headroom; clears 28 in. utility doorway (24.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-15 | Certified 2026-10-15 | Markets: United States |

## How Do Regional kWh Prices Impact PROUH65 T2 RU350UM Over 10 Years?

Using EIA Table 5.6.A benchmarks, Ruud PROUH65 T2 RU350UM's 900 kWh/yr draw translates to roughly $163/yr on typical US residential bills.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $163/yr | $1,634 | $4,584 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $425/yr | $4,246 | $11,908 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $268/yr | $2,678 | $7,509 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $143/yr | $1,432 | $4,016 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $132/yr | $1,317 | $3,693 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (900 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## What Should Ruud Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC SaferProducts snapshot includes 2 filings tied to Ruud; verify whether your PROUH65 T2 RU350UM production run falls inside affected ranges. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

**2 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range**

- **Recall #07108 (2007-02-21):** Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard ([CPSC Notice](https://www.cpsc.gov/Recalls/2007/Tankless-Water-Heaters-Recalled-for-Repair-Due-to-Carbon-Monoxide-Poisoning-Hazard))
- **Recall #05274 (2005-09-16):** CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters ([CPSC Notice](https://www.cpsc.gov/Recalls/2005/CPSC-Robertshaw-Controls-Co-Announce-Recall-of-Gas-Control-Valves-on-Water-Heaters-))

## How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?

Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Friedrich PROH65 T2 FD310BM](https://gcsradheat.com/water-heaters/friedrich/proh65-t2-fd310bm/) | Hybrid/Electric Heat Pump | 59 gal | 75 gal | 3.5 (at parity) | 900 |
| [Rheem CPRO H65 T2 RH310BM](https://gcsradheat.com/water-heaters/rheem/cpro-h65-t2-rh310bm/) | Hybrid/Electric Heat Pump | 59 gal | 75 gal | 3.5 (at parity) | 900 |
| [Richmond 10CE65-HP5U15](https://gcsradheat.com/water-heaters/richmond/10ce65-hp5u15/) | Hybrid/Electric Heat Pump | 59 gal | 54 gal | 3.55 (+0.05) | 887 |
| [A. O. Smith HPACO-45 1**+AXST-66 1**](https://gcsradheat.com/water-heaters/a-o-smith/hpaco-45-1-axst-66-1/) | Hybrid/Electric Heat Pump | 60 gal | 82 gal | 3.7 (+0.20) | 1,341 |
| [Friedrich PROH65 T2 FD310UM](https://gcsradheat.com/water-heaters/friedrich/proh65-t2-fd310um/) | Hybrid/Electric Heat Pump | 59 gal | 75 gal | 3.5 (at parity) | 900 |

## What Installation Caveats Apply Before Buying Ruud PROUH65 T2 RU350UM?

Even high-UEF units like Ruud PROUH65 T2 RU350UM (3.5 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

### Key Limitations & Exclusions

- Ruud PROUH65 T2 RU350UM needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Ruud PROUH65 T2 RU350UM directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing Ruud PROUH65 T2 RU350UM** Strong Fit — 3.5 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare Friedrich PROH65 T2 FD310BM footprint.

## Frequently Asked Technical Questions: Ruud PROUH65 T2 RU350UM

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Is Ruud PROUH65 T2 RU350UM eligible for continued manufacture past May 6, 2029?

At 3.5 UEF, Ruud PROUH65 T2 RU350UM achieves Pass: +1.00 / +40.0% for the 2029 DOE standard and stands #481 of 706 against Friedrich PROH65 T2 FD310BM and Rheem CPRO H65 T2 RH310BM.

### How tall and wide is Ruud PROUH65 T2 RU350UM, and what service clearance is needed?

Physical dimensions for Ruud PROUH65 T2 RU350UM are 64.2 in. height and 24.3 in. diameter (verify 72 in. vertical headroom; clears 28 in. utility doorway (24.3" d)); verify stair turns and drain pan width before delivery.

### Will Ruud PROUH65 T2 RU350UM require upgrading household electrical panels or gas piping?

Ruud PROUH65 T2 RU350UM draws 240V at 21A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.

### Is Ruud PROUH65 T2 RU350UM economical to operate at 18.16 cents/kWh US electric rates?

Expect roughly $163/yr ($1,630 over 10 years) to power Ruud PROUH65 T2 RU350UM at 900 kWh/yr under the 18.16 cents/kWh US average (ranging from $132/yr in Washington hydro tiers up to $425/yr in Hawaii).

### Which installation bottlenecks limit Ruud PROUH65 T2 RU350UM?

If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, Ruud PROUH65 T2 RU350UM drops into resistance mode more often.

### How does Ruud PROUH65 T2 RU350UM handle simultaneous showers and laundry?

Delivering 75 gal in the first hour (+3 gal vs. 72 gal median), Ruud PROUH65 T2 RU350UM combines 59 gal tank storage with rapid burner/element recovery.

### How long is the warranty on Ruud PROUH65 T2 RU350UM and how do you decode its serial?

CPSC SaferProducts records show 2 brand-level recall notices mentioning Ruud as of 2026-11-23, including #07108 (2007-02-21). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

### How do 2026 post-OBBBA rebates affect buying Ruud PROUH65 T2 RU350UM?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH65 T2 FD310BM (3.5 UEF).

## Essential Pre-Install Guides for Ruud PROUH65 T2 RU350UM

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Friedrich PROH65 T2 FD310BM (3.5 UEF)→](https://gcsradheat.com/water-heaters/friedrich/proh65-t2-fd310bm/)
- [Compare Rheem CPRO H65 T2 RH310BM (3.5 UEF)→](https://gcsradheat.com/water-heaters/rheem/cpro-h65-t2-rh310bm/)
- [View All Ruud Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/ruud/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)