title: "Ruud PROUH80 T2 RU350UM (3.5 UEF, 72 gal)"
url: https://gcsradheat.com/water-heaters/ruud/prouh80-t2-ru350um/
description: "Certified at 3.5 UEF across its 72-gallon nominal tank, 87 gal First Hour Rating, Ruud PROUH80 T2 RU350UM (Hybrid/Electric Heat Pump, Electric) places #481 of."
---

ENERGY STAR water heater model · PD 3994211

# Ruud PROUH80 T2 RU350UM Water Heater Specifications (3.5 UEF)

Certified at 3.5 UEF across its 72-gallon nominal tank, 87 gal First Hour Rating, Ruud PROUH80 T2 RU350UM (Hybrid/Electric Heat Pump, Electric) places #481 of 706 out of 706 ENERGY STAR models (PD 3994211). Its May 6, 2029 10 CFR 430.32 status reads Pass: +1.00 / +40.0%. Rated annual electricity draw of 1,303 kWh/yr equates to roughly $237/yr ($2,366 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH80 T2 FD310BM (3.5 UEF).

- **Uniform Energy Factor**: 3.5 UEF

- **Cohort UEF Rank**: #481 of 706

- **First Hour Rating**: 87 gal

- **Storage Volume**: 72 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.00 / +40.0%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Ruud PROUH80 T2 RU350UM relative to the cohort median.

Efficiency comparison & rule summary

Tested at 3.5 UEF, Ruud PROUH80 T2 RU350UM places #481 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (-0.20 UEF vs. 3.70 UEF median).

Ruud PROUH80 T2 RU350UM clears 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +1.00 UEF (+40.0% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 1,303 kWh/yr for Ruud PROUH80 T2 RU350UM runs ~$237/yr vs. ~$900/yr for a 0.92 UEF electric tank.

State electric sensitivity for Ruud PROUH80 T2 RU350UM: 10-year operating spend spans $1,906 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,148 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Closest alternatives to Ruud PROUH80 T2 RU350UM include Friedrich PROH80 T2 FD310BM (3.5 UEF, at parity) alongside Rheem CPROPH80 T2 RH350BM (3.5 UEF, at parity).

## What Physical and Thermal Ratings Define Ruud PROUH80 T2 RU350UM?

Positioning at #481 of 706 out of 706 Hybrid/Electric Heat Pump peers, Ruud PROUH80 T2 RU350UM pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Ruud](https://gcsradheat.com/brands/ruud/) | 95 certified listings | ENERGY STAR PD 3994211 |
| Model Number | PROUH80 T2 RU350UM | Draw pattern: High-Usage | PROUH80 T2 RU350UM |
| Uniform Energy Factor (UEF) | 3.5 | -0.20 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 87 gal | +15 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,303 kWh/yr | +231 kWh/yr vs. 1,072 kWh/yr median | Est. $237/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 398% | -31.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 74.2" H x 24.3" D | Needs >72 in. overhead clearance; clears 28 in. utility doorway (24.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-15 | Certified 2026-10-15 | Markets: United States |

## Why Do State Utility Rates Shift PROUH80 T2 RU350UM Running Costs?

Consuming 1,303 kWh annually puts Ruud PROUH80 T2 RU350UM near $237/yr at US baseline tariffs, with multi-state EIA comparisons charted below.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $237/yr | $2,366 | $6,636 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $615/yr | $6,148 | $17,240 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $388/yr | $3,876 | $10,871 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $207/yr | $2,073 | $5,814 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $191/yr | $1,906 | $5,346 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (1,303 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Have Any Ruud Series Triggered CPSC Recalls?

SaferProducts records retrieved 2026-11-23 list 2 brand notices under Ruud; inspect model coverage dates prior to valve or anode service. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

**2 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range**

- **Recall #07108 (2007-02-21):** Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard ([CPSC Notice](https://www.cpsc.gov/Recalls/2007/Tankless-Water-Heaters-Recalled-for-Repair-Due-to-Carbon-Monoxide-Poisoning-Hazard))
- **Recall #05274 (2005-09-16):** CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters ([CPSC Notice](https://www.cpsc.gov/Recalls/2005/CPSC-Robertshaw-Controls-Co-Announce-Recall-of-Gas-Control-Valves-on-Water-Heaters-))

## What Are 5 Direct Alternatives to Ruud PROUH80 T2 RU350UM?

Homeowners cross-shopping Ruud PROUH80 T2 RU350UM frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Friedrich PROH80 T2 FD310BM](https://gcsradheat.com/water-heaters/friedrich/proh80-t2-fd310bm/) | Hybrid/Electric Heat Pump | 72 gal | 87 gal | 3.5 (at parity) | 1,303 |
| [Rheem CPROPH80 T2 RH350BM](https://gcsradheat.com/water-heaters/rheem/cproph80-t2-rh350bm/) | Hybrid/Electric Heat Pump | 72 gal | 87 gal | 3.5 (at parity) | 1,303 |
| [Richmond 10E80-HP120M](https://gcsradheat.com/water-heaters/richmond/10e80-hp120m/) | Hybrid/Electric Heat Pump | 72 gal | 84 gal | 3.46 (-0.04) | 1,403 |
| [LG APHWC801D](https://gcsradheat.com/water-heaters/lg/aphwc801d/) | Hybrid/Electric Heat Pump | 72 gal | 94 gal | 3.9 (+0.40) | 1,272 |
| [Friedrich PROH80 T2 FD310UM](https://gcsradheat.com/water-heaters/friedrich/proh80-t2-fd310um/) | Hybrid/Electric Heat Pump | 72 gal | 87 gal | 3.5 (at parity) | 1,303 |

## What Installation Caveats Apply Before Buying Ruud PROUH80 T2 RU350UM?

Even high-UEF units like Ruud PROUH80 T2 RU350UM (3.5 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

### Key Limitations & Exclusions

- Ruud PROUH80 T2 RU350UM needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Ruud PROUH80 T2 RU350UM directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing Ruud PROUH80 T2 RU350UM** Strong Fit — 3.5 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare Friedrich PROH80 T2 FD310BM footprint.

## Sizing, Efficiency & Recall Answers for Ruud PROUH80 T2 RU350UM

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Is Ruud PROUH80 T2 RU350UM eligible for continued manufacture past May 6, 2029?

At 3.5 UEF, Ruud PROUH80 T2 RU350UM achieves Pass: +1.00 / +40.0% for the 2029 DOE standard and stands #481 of 706 against Friedrich PROH80 T2 FD310BM and Rheem CPROPH80 T2 RH350BM.

### How tall and wide is Ruud PROUH80 T2 RU350UM, and what service clearance is needed?

Physical dimensions for Ruud PROUH80 T2 RU350UM are 74.2 in. height and 24.3 in. diameter (needs >72 in. overhead clearance; clears 28 in. utility doorway (24.3" d)); verify stair turns and drain pan width before delivery.

### Will Ruud PROUH80 T2 RU350UM require upgrading household electrical panels or gas piping?

Ruud PROUH80 T2 RU350UM draws 240V at 21A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.

### Is Ruud PROUH80 T2 RU350UM economical to operate at 18.16 cents/kWh US electric rates?

Expect roughly $237/yr ($2,370 over 10 years) to power Ruud PROUH80 T2 RU350UM at 1,303 kWh/yr under the 18.16 cents/kWh US average (ranging from $191/yr in Washington hydro tiers up to $615/yr in Hawaii).

### Which installation bottlenecks limit Ruud PROUH80 T2 RU350UM?

If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, Ruud PROUH80 T2 RU350UM drops into resistance mode more often.

### How does Ruud PROUH80 T2 RU350UM handle simultaneous showers and laundry?

Delivering 87 gal in the first hour (+15 gal vs. 72 gal median), Ruud PROUH80 T2 RU350UM combines 72 gal tank storage with rapid burner/element recovery.

### How long is the warranty on Ruud PROUH80 T2 RU350UM and how do you decode its serial?

CPSC SaferProducts records show 2 brand-level recall notices mentioning Ruud as of 2026-11-23, including #07108 (2007-02-21). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

### How do 2026 post-OBBBA rebates affect buying Ruud PROUH80 T2 RU350UM?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH80 T2 FD310BM (3.5 UEF).

## Related Rebate, Gas-Line & Serial Tools for PROUH80 T2 RU350UM

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Friedrich PROH80 T2 FD310BM (3.5 UEF)→](https://gcsradheat.com/water-heaters/friedrich/proh80-t2-fd310bm/)
- [Compare Rheem CPROPH80 T2 RH350BM (3.5 UEF)→](https://gcsradheat.com/water-heaters/rheem/cproph80-t2-rh350bm/)
- [View All Ruud Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/ruud/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)