title: "SANCO2 GS5-45HPC-D HP + ECO-119GLBK (3.72 UEF, 119 gal)"
url: https://gcsradheat.com/water-heaters/sanco2/gs5-45hpc-d-hp-eco-119glbk/
description: "The SANCO2 GS5-45HPC-D HP + ECO-119GLBK (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.72 UEF rating across its 119-gallon nominal tank, 134 gal."
---

ENERGY STAR water heater model · PD 3624320

# SANCO2 GS5-45HPC-D HP + ECO-119GLBK Water Heater Specifications (3.72 UEF)

The SANCO2 GS5-45HPC-D HP + ECO-119GLBK (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.72 UEF rating across its 119-gallon nominal tank, 134 gal First Hour Rating, ranking #345 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 3624320). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +1.22 / +48.8%. Rated annual electricity draw of 1,333 kWh/yr equates to roughly $242/yr ($2,421 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Reclaim Energy MP120F-RC (3.75 UEF).

- **Uniform Energy Factor**: 3.72 UEF

- **Cohort UEF Rank**: #345 of 706

- **First Hour Rating**: 134 gal

- **Storage Volume**: 119 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.22 / +48.8%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows SANCO2 GS5-45HPC-D HP + ECO-119GLBK relative to the cohort median.

Efficiency comparison & rule summary

SANCO2 GS5-45HPC-D HP + ECO-119GLBK (3.72 UEF) ranks #345 of 706 Hybrid/Electric Heat Pump models — 2-way tie; more efficient than 51% of Hybrid/Electric Heat Pump models, +0.02 UEF above the 3.70 UEF median.

Federal 2029 margin for SANCO2 GS5-45HPC-D HP + ECO-119GLBK: +1.22 UEF (+48.8%) vs. 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,333 kWh/yr for SANCO2 GS5-45HPC-D HP + ECO-119GLBK runs ~$242/yr vs. ~$979/yr for a 0.92 UEF electric tank. Acoustic output is 37 dBA (quieter than 93.3% of Hybrid/Electric Heat Pump models).

State electric sensitivity for SANCO2 GS5-45HPC-D HP + ECO-119GLBK: 10-year operating spend spans $1,950 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,289 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Peer comparison: SANCO2 GS5-45HPC-D HP + ECO-119GLBK (3.72 UEF) compares closely with Reclaim Energy MP120F-RC (3.75 UEF, delta +0.03) and VAUGHN THERMAL MP120F-RC (3.75 UEF, delta +0.03).

## Where Does SANCO2 GS5-45HPC-D HP + ECO-119GLBK Rank Against Peer Hybrid/Electric Heat Pump Units?

Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, SANCO2 GS5-45HPC-D HP + ECO-119GLBK holds #345 of 706; inspect footprint, circuit load, and efficiency deltas here.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [SANCO2](https://gcsradheat.com/brands/sanco2/) | 6 certified listings | ENERGY STAR PD 3624320 |
| Model Number | GS5-45HPC-D HP + ECO-119GLBK | Draw pattern: High-Usage | GS5-45HPC-D HP + ECO-119GLBK |
| Uniform Energy Factor (UEF) | 3.72 | +0.02 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 134 gal | +62 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,333 kWh/yr | +261 kWh/yr vs. 1,072 kWh/yr median | Est. $242/yr @ $0.1816/kWh (EIA US Avg) |
| Electrical Circuit Requirements | 230 V / 7 A max | Verify rating plate electrical draw | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-744 (CO₂) (GWP:1 / Lower GWP) | Lower-GWP refrigerant alignment (EPA AIM Act) | EPA AIM Act Compliance |
| Sound Pressure Level | 37 dBA | top 6.7% · quieter than 93.3% of Hybrid/Electric Heat Pump models · -12 dBA vs. 49 dBA median | Indoor placement check |
| Certification Date | 2014-08-21 | Certified 2014-08-21 | Markets: United States, Canada |

## How Much Electricity Does GS5-45HPC-D HP + ECO-119GLBK Use in Different States?

Estimated at $242/yr nationally (1,333 kWh/yr), 10-year utility spending for SANCO2 GS5-45HPC-D HP + ECO-119GLBK shifts sharply between low-rate hydro and coastal grids.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $242/yr | $2,421 | $7,368 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $629/yr | $6,289 | $19,141 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $397/yr | $3,966 | $12,070 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $212/yr | $2,121 | $6,455 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $195/yr | $1,950 | $5,935 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (1,333 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Does CPSC Flag Any Safety Notices on SANCO2 Units?

No open CPSC recall alerts appeared for SANCO2 as of 2026-11-23; you can still decode exact manufacture month and warranty window below. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## Which Competing Hybrid/Electric Heat Pump Models Compare Closest to GS5-45HPC-D HP + ECO-119GLBK?

Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to SANCO2 GS5-45HPC-D HP + ECO-119GLBK's gallon capacity and 3.72 UEF efficiency.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Reclaim Energy MP120F-RC](https://gcsradheat.com/water-heaters/reclaim-energy/mp120f-rc/) | Hybrid/Electric Heat Pump | 119 gal | 121 gal | 3.75 (+0.03) | 1,296 |
| [VAUGHN THERMAL MP120F-RC](https://gcsradheat.com/water-heaters/vaughn-thermal/mp120f-rc/) | Hybrid/Electric Heat Pump | 119 gal | 121 gal | 3.75 (+0.03) | 1,296 |
| [Smart Solar SSG2-ES 120](https://gcsradheat.com/water-heaters/smart-solar/ssg2-es-120/) | Hybrid/Electric Heat Pump | 120 gal | 83 gal | 2.85 (-0.87) | 1,741 |
| [Hubbell ME120HPT](https://gcsradheat.com/water-heaters/hubbell/me120hpt/) | Hybrid/Electric Heat Pump | 109 gal | 105 gal | 3.38 (-0.34) | 1,467 |
| [VAUGHN THERMAL MP120FHPT](https://gcsradheat.com/water-heaters/vaughn-thermal/mp120fhpt/) | Hybrid/Electric Heat Pump | 119 gal | 115 gal | 3.5 (-0.22) | 1,418 |

## What Installation Caveats Apply Before Buying SANCO2 GS5-45HPC-D HP + ECO-119GLBK?

Even high-UEF units like SANCO2 GS5-45HPC-D HP + ECO-119GLBK (3.72 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

### Key Limitations & Exclusions

- SANCO2 GS5-45HPC-D HP + ECO-119GLBK needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 37 dBA; avoid mounting SANCO2 GS5-45HPC-D HP + ECO-119GLBK directly beside quiet bedrooms.
- Requires condensate drain routing and 230V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing SANCO2 GS5-45HPC-D HP + ECO-119GLBK** Strong Fit — 3.72 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare Reclaim Energy MP120F-RC footprint.

## Common Homeowner Questions for SANCO2 GS5-45HPC-D HP + ECO-119GLBK

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Is SANCO2 GS5-45HPC-D HP + ECO-119GLBK eligible for continued manufacture past May 6, 2029?

At 3.72 UEF, SANCO2 GS5-45HPC-D HP + ECO-119GLBK achieves Pass: +1.22 / +48.8% for the 2029 DOE standard and stands #345 of 706 against Reclaim Energy MP120F-RC and VAUGHN THERMAL MP120F-RC.

### How tall and wide is SANCO2 GS5-45HPC-D HP + ECO-119GLBK, and what service clearance is needed?

SANCO2 GS5-45HPC-D HP + ECO-119GLBK saves floor space via its hybrid/electric heat pump layout (wall-hung / compact envelope); inspect service-valve swing clearance below the bottom manifold.

### Will SANCO2 GS5-45HPC-D HP + ECO-119GLBK require upgrading household electrical panels or gas piping?

SANCO2 GS5-45HPC-D HP + ECO-119GLBK draws 230V at 7A max (Verify rating plate electrical draw); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.

### Is SANCO2 GS5-45HPC-D HP + ECO-119GLBK economical to operate at 18.16 cents/kWh US electric rates?

Expect roughly $242/yr ($2,420 over 10 years) to power SANCO2 GS5-45HPC-D HP + ECO-119GLBK at 1,333 kWh/yr under the 18.16 cents/kWh US average (ranging from $195/yr in Washington hydro tiers up to $629/yr in Hawaii).

### Which installation bottlenecks limit SANCO2 GS5-45HPC-D HP + ECO-119GLBK?

If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, SANCO2 GS5-45HPC-D HP + ECO-119GLBK drops into resistance mode more often.

### How does SANCO2 GS5-45HPC-D HP + ECO-119GLBK handle simultaneous showers and laundry?

Delivering 134 gal in the first hour (+62 gal vs. 72 gal median), SANCO2 GS5-45HPC-D HP + ECO-119GLBK combines 119 gal tank storage with rapid burner/element recovery.

### How long is the warranty on SANCO2 GS5-45HPC-D HP + ECO-119GLBK and how do you decode its serial?

CPSC records show 0 active plumbing recalls for SANCO2 as of 2026-11-23. Confirm install proof and serial manufacture year on SANCO2 GS5-45HPC-D HP + ECO-119GLBK before calling service.

### How do 2026 post-OBBBA rebates affect buying SANCO2 GS5-45HPC-D HP + ECO-119GLBK?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is Reclaim Energy MP120F-RC (3.75 UEF).

## Next Engineering Checks for SANCO2 Owners

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Reclaim Energy MP120F-RC (3.75 UEF)→](https://gcsradheat.com/water-heaters/reclaim-energy/mp120f-rc/)
- [Compare VAUGHN THERMAL MP120F-RC (3.75 UEF)→](https://gcsradheat.com/water-heaters/vaughn-thermal/mp120f-rc/)
- [View All SANCO2 Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/sanco2/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)