title: "SANCO2 GS5-45HPC-D HP + ECO-43SSAQB (3.7 UEF, 43 gal)"
url: https://gcsradheat.com/water-heaters/sanco2/gs5-45hpc-d-hp-eco-43ssaqb/
description: "Engineered as a Electric Hybrid/Electric Heat Pump unit, SANCO2 GS5-45HPC-D HP + ECO-43SSAQB achieves a certified 3.7 UEF rating across its 43-gallon nominal."
---

ENERGY STAR water heater model · PD 3701842

# SANCO2 GS5-45HPC-D HP + ECO-43SSAQB Water Heater Specifications (3.7 UEF)

Engineered as a Electric Hybrid/Electric Heat Pump unit, SANCO2 GS5-45HPC-D HP + ECO-43SSAQB achieves a certified 3.7 UEF rating across its 43-gallon nominal tank, 73 gal First Hour Rating and ranks #347 of 706 in its 706-model cohort (PD 3701842), recording Pass: +1.40 / +60.9% under 2029 DOE rules. Rated annual electricity draw of 868 kWh/yr equates to roughly $158/yr ($1,576 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Navien NWP500S050AUMB (3.85 UEF).

- **Uniform Energy Factor**: 3.7 UEF

- **Cohort UEF Rank**: #347 of 706

- **First Hour Rating**: 73 gal

- **Storage Volume**: 43 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.40 / +60.9%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows SANCO2 GS5-45HPC-D HP + ECO-43SSAQB relative to the cohort median.

Efficiency comparison & rule summary

Within the 706-unit Hybrid/Electric Heat Pump cohort, SANCO2 GS5-45HPC-D HP + ECO-43SSAQB logs 3.7 UEF and ranks #347 of 706.

Against 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF), SANCO2 GS5-45HPC-D HP + ECO-43SSAQB holds a +1.40 UEF (+60.9%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 868 kWh/yr for SANCO2 GS5-45HPC-D HP + ECO-43SSAQB runs ~$158/yr vs. ~$634/yr for a 0.92 UEF electric tank. Acoustic output is 37 dBA (quieter than 93.3% of Hybrid/Electric Heat Pump models).

State electric sensitivity for SANCO2 GS5-45HPC-D HP + ECO-43SSAQB: 10-year operating spend spans $1,270 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,095 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Cross-shopping SANCO2 GS5-45HPC-D HP + ECO-43SSAQB (3.7 UEF)? Check Navien NWP500S050AUMB (3.85 UEF, delta +0.15) and Arctic Arctic-HP-Hot Water-KA06-50 (3.88 UEF, delta +0.18).

## What Physical and Thermal Ratings Define SANCO2 GS5-45HPC-D HP + ECO-43SSAQB?

Positioning at #347 of 706 out of 706 Hybrid/Electric Heat Pump peers, SANCO2 GS5-45HPC-D HP + ECO-43SSAQB pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [SANCO2](https://gcsradheat.com/brands/sanco2/) | 6 certified listings | ENERGY STAR PD 3701842 |
| Model Number | GS5-45HPC-D HP + ECO-43SSAQB | Draw pattern: Medium-Usage | GS5-45HPC-D HP + ECO-43SSAQB |
| Uniform Energy Factor (UEF) | 3.7 | At 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 73 gal | +1 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 868 kWh/yr | -204 kWh/yr vs. 1,072 kWh/yr median | Est. $158/yr @ $0.1816/kWh (EIA US Avg) |
| Electrical Circuit Requirements | 230 V / 7 A max | Verify rating plate electrical draw | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-744 (CO₂) (GWP:1 / Lower GWP) | Lower-GWP refrigerant alignment (EPA AIM Act) | EPA AIM Act Compliance |
| Sound Pressure Level | 37 dBA | top 6.7% · quieter than 93.3% of Hybrid/Electric Heat Pump models · -12 dBA vs. 49 dBA median | Indoor placement check |
| Certification Date | 2024-10-09 | Certified 2024-10-09 | Markets: United States, Canada |

## Why Do State Utility Rates Shift GS5-45HPC-D HP + ECO-43SSAQB Running Costs?

Consuming 868 kWh annually puts SANCO2 GS5-45HPC-D HP + ECO-43SSAQB near $158/yr at US baseline tariffs, with multi-state EIA comparisons charted below.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $158/yr | $1,576 | $4,763 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $410/yr | $4,095 | $12,375 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $258/yr | $2,582 | $7,803 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $138/yr | $1,381 | $4,173 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $127/yr | $1,270 | $3,837 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (868 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Have Any SANCO2 Series Triggered CPSC Recalls?

SaferProducts screening on 2026-11-23 returned zero recall matches for SANCO2; confirm tank age separately using the rating-plate serial pattern. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## What Are 5 Direct Alternatives to SANCO2 GS5-45HPC-D HP + ECO-43SSAQB?

Homeowners cross-shopping SANCO2 GS5-45HPC-D HP + ECO-43SSAQB frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Navien NWP500S050AUMB](https://gcsradheat.com/water-heaters/navien/nwp500s050aumb/) | Hybrid/Electric Heat Pump | 44 gal | 65 gal | 3.85 (+0.15) | 840 |
| [Arctic Arctic-HP-Hot Water-KA06-50](https://gcsradheat.com/water-heaters/arctic/arctic-hp-hot-water-ka06-50/) | Hybrid/Electric Heat Pump | 44.5 gal | 65 gal | 3.88 (+0.18) | 837 |
| [PHNIX KA06-50](https://gcsradheat.com/water-heaters/phnix/ka06-50/) | Hybrid/Electric Heat Pump | 44.5 gal | 65 gal | 3.88 (+0.18) | 837 |
| [AMERICAN STANDARD WATER HEATERS ASHPWH-50*](https://gcsradheat.com/water-heaters/american-standard-water-heaters/ashpwh-50/) | Hybrid/Electric Heat Pump | 45 gal | 68 gal | 3.75 (+0.05) | 867 |
| [Ariston ARIHPWH-50](https://gcsradheat.com/water-heaters/ariston/arihpwh-50/) | Hybrid/Electric Heat Pump | 45 gal | 68 gal | 3.75 (+0.05) | 867 |

## Which Home Setups Are NOT a Fit for SANCO2 GS5-45HPC-D HP + ECO-43SSAQB?

Comparing SANCO2 GS5-45HPC-D HP + ECO-43SSAQB against Navien NWP500S050AUMB requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

### Key Limitations & Exclusions

- SANCO2 GS5-45HPC-D HP + ECO-43SSAQB needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 37 dBA; avoid mounting SANCO2 GS5-45HPC-D HP + ECO-43SSAQB directly beside quiet bedrooms.
- Requires condensate drain routing and 230V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing SANCO2 GS5-45HPC-D HP + ECO-43SSAQB** Strong Fit — 3.7 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare Navien NWP500S050AUMB footprint.

## Sizing, Efficiency & Recall Answers for SANCO2 GS5-45HPC-D HP + ECO-43SSAQB

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### How does SANCO2 GS5-45HPC-D HP + ECO-43SSAQB score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; SANCO2 GS5-45HPC-D HP + ECO-43SSAQB logs 3.7 UEF (Pass: +1.40 / +60.9%) within the 706-unit Hybrid/Electric Heat Pump group.

### What physical clearance dimensions apply when installing SANCO2 GS5-45HPC-D HP + ECO-43SSAQB?

Because SANCO2 GS5-45HPC-D HP + ECO-43SSAQB is a hybrid/electric heat pump unit (wall-hung / compact envelope), check wall-stud backing, condensate neutralizer routing, and outdoor vent clearances first.

### What 240V circuit or IFGC fuel line capacity fits SANCO2 GS5-45HPC-D HP + ECO-43SSAQB?

Powered via 230V at 7A max, SANCO2 GS5-45HPC-D HP + ECO-43SSAQB requires: Verify rating plate electrical draw. Confirm double-pole breaker sizing and condensate pump outlet proximity.

### How do state electricity prices change annual costs for SANCO2 GS5-45HPC-D HP + ECO-43SSAQB?

Annual electric spend for SANCO2 GS5-45HPC-D HP + ECO-43SSAQB (868 kWh/yr) averages $158/yr nationwide (ranging from $127/yr in Washington hydro tiers up to $410/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.

### What homeowner setups should avoid choosing SANCO2 GS5-45HPC-D HP + ECO-43SSAQB?

Homes lacking a condensate drain or 230V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on SANCO2 GS5-45HPC-D HP + ECO-43SSAQB.

### Is SANCO2 GS5-45HPC-D HP + ECO-43SSAQB sized adequately for a 2-to-4-person household?

ENERGY STAR certifies SANCO2 GS5-45HPC-D HP + ECO-43SSAQB at 73 gal First Hour Rating (+1 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.

### Does SANCO2 have active CPSC SaferProducts notices affecting GS5-45HPC-D HP + ECO-43SSAQB?

Zero CPSC recall alerts matched SANCO2 (2026-11-23 check). Keep your SANCO2 GS5-45HPC-D HP + ECO-43SSAQB serial code handy to track standard 6-to-12-year OEM warranty coverage.

### Which competing water heater matches SANCO2 GS5-45HPC-D HP + ECO-43SSAQB (3.7 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for SANCO2 GS5-45HPC-D HP + ECO-43SSAQB. Closest peer in Hybrid/Electric Heat Pump is Navien NWP500S050AUMB (3.85 UEF).

## Related Rebate, Gas-Line & Serial Tools for GS5-45HPC-D HP + ECO-43SSAQB

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Navien NWP500S050AUMB (3.85 UEF)→](https://gcsradheat.com/water-heaters/navien/nwp500s050aumb/)
- [Compare Arctic Arctic-HP-Hot Water-KA06-50 (3.88 UEF)→](https://gcsradheat.com/water-heaters/arctic/arctic-hp-hot-water-ka06-50/)
- [View All SANCO2 Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/sanco2/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)