title: "SANCO2 GS5-45HPC HP + ECO-83SSAQB (3.8 UEF, 83 gal)"
url: https://gcsradheat.com/water-heaters/sanco2/gs5-45hpc-hp-eco-83ssaqb/
description: "Engineered as a Electric Hybrid/Electric Heat Pump unit, SANCO2 GS5-45HPC HP + ECO-83SSAQB achieves a certified 3.8 UEF rating across its 83-gallon nominal."
---

ENERGY STAR water heater model · PD 3624317

# SANCO2 GS5-45HPC HP + ECO-83SSAQB Water Heater Specifications (3.8 UEF)

Engineered as a Electric Hybrid/Electric Heat Pump unit, SANCO2 GS5-45HPC HP + ECO-83SSAQB achieves a certified 3.8 UEF rating across its 83-gallon nominal tank, 121 gal First Hour Rating and ranks #268 of 706 in its 706-model cohort (PD 3624317), recording Pass: +1.30 / +52.0% under 2029 DOE rules. Rated annual electricity draw of 1,313 kWh/yr equates to roughly $238/yr ($2,384 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPS10-80H45DV 2** (3.88 UEF).

- **Uniform Energy Factor**: 3.8 UEF

- **Cohort UEF Rank**: #268 of 706 (top 41.9%)

- **First Hour Rating**: 121 gal

- **Storage Volume**: 83 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.30 / +52.0%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows SANCO2 GS5-45HPC HP + ECO-83SSAQB relative to the cohort median.

Efficiency comparison & rule summary

Within the 706-unit Hybrid/Electric Heat Pump cohort, SANCO2 GS5-45HPC HP + ECO-83SSAQB logs 3.8 UEF and ranks #268 of 706.

Against 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF), SANCO2 GS5-45HPC HP + ECO-83SSAQB holds a +1.30 UEF (+52.0%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 1,313 kWh/yr for SANCO2 GS5-45HPC HP + ECO-83SSAQB runs ~$238/yr vs. ~$985/yr for a 0.92 UEF electric tank. Acoustic output is 37 dBA (quieter than 93.3% of Hybrid/Electric Heat Pump models).

State electric sensitivity for SANCO2 GS5-45HPC HP + ECO-83SSAQB: 10-year operating spend spans $1,921 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,195 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Cross-shopping SANCO2 GS5-45HPC HP + ECO-83SSAQB (3.8 UEF)? Check A. O. Smith HPS10-80H45DV 2** (3.88 UEF, delta +0.08) and American HPS10280H045DV 2** (3.88 UEF, delta +0.08).

## Where Does SANCO2 GS5-45HPC HP + ECO-83SSAQB Rank Against Peer Hybrid/Electric Heat Pump Units?

Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, SANCO2 GS5-45HPC HP + ECO-83SSAQB holds #268 of 706 (top 41.9%); inspect footprint, circuit load, and efficiency deltas here.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [SANCO2](https://gcsradheat.com/brands/sanco2/) | 6 certified listings | ENERGY STAR PD 3624317 |
| Model Number | GS5-45HPC HP + ECO-83SSAQB | Draw pattern: High-Usage | GS5-45HPC HP + ECO-83SSAQB |
| Uniform Energy Factor (UEF) | 3.8 | +0.10 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 121 gal | +49 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,313 kWh/yr | +241 kWh/yr vs. 1,072 kWh/yr median | Est. $238/yr @ $0.1816/kWh (EIA US Avg) |
| Electrical Circuit Requirements | 230 V / 7 A max | Verify rating plate electrical draw | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-744 (CO₂) (GWP:1 / Lower GWP) | Lower-GWP refrigerant alignment (EPA AIM Act) | EPA AIM Act Compliance |
| Sound Pressure Level | 37 dBA | top 6.7% · quieter than 93.3% of Hybrid/Electric Heat Pump models · -12 dBA vs. 49 dBA median | Indoor placement check |
| Certification Date | 2024-08-21 | Certified 2024-08-21 | Markets: United States, Canada |

## How Much Electricity Does GS5-45HPC HP + ECO-83SSAQB Use in Different States?

Estimated at $238/yr nationally (1,313 kWh/yr), 10-year utility spending for SANCO2 GS5-45HPC HP + ECO-83SSAQB shifts sharply between low-rate hydro and coastal grids.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $238/yr | $2,384 | $7,464 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $619/yr | $6,195 | $19,391 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $391/yr | $3,906 | $12,227 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $209/yr | $2,089 | $6,539 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $192/yr | $1,921 | $6,013 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (1,313 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Does CPSC Flag Any Safety Notices on SANCO2 Units?

No open CPSC recall alerts appeared for SANCO2 as of 2026-11-23; you can still decode exact manufacture month and warranty window below. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## Which Competing Hybrid/Electric Heat Pump Models Compare Closest to GS5-45HPC HP + ECO-83SSAQB?

Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to SANCO2 GS5-45HPC HP + ECO-83SSAQB's gallon capacity and 3.8 UEF efficiency.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [A. O. Smith HPS10-80H45DV 2**](https://gcsradheat.com/water-heaters/a-o-smith/hps10-80h45dv-2/) | Hybrid/Electric Heat Pump | 82 gal | 95 gal | 3.88 (+0.08) | 1,279 |
| [American HPS10280H045DV 2**](https://gcsradheat.com/water-heaters/american/hps10280h045dv-2/) | Hybrid/Electric Heat Pump | 82 gal | 95 gal | 3.88 (+0.08) | 1,279 |
| [Lochinvar HPSA080KD 2**](https://gcsradheat.com/water-heaters/lochinvar/hpsa080kd-2/) | Hybrid/Electric Heat Pump | 82 gal | 95 gal | 3.88 (+0.08) | 1,279 |
| [RELIANCE WATER HEATERS 10-80-DHPTS 2**](https://gcsradheat.com/water-heaters/reliance-water-heaters/10-80-dhpts-2/) | Hybrid/Electric Heat Pump | 82 gal | 95 gal | 3.88 (+0.08) | 1,279 |
| [A. O. Smith HPSN10-80H45DV 2**](https://gcsradheat.com/water-heaters/a-o-smith/hpsn10-80h45dv-2/) | Hybrid/Electric Heat Pump | 82 gal | 95 gal | 3.88 (+0.08) | 1,279 |

## What Are the Limitations of SANCO2 GS5-45HPC HP + ECO-83SSAQB and Who Should Not Install It?

Before ordering SANCO2 GS5-45HPC HP + ECO-83SSAQB (Hybrid/Electric Heat Pump, 3.8 UEF), weigh space clearances, fuel piping, noise (37 dBA), and 2029 rule readiness across three scenarios.

### Key Limitations & Exclusions

- SANCO2 GS5-45HPC HP + ECO-83SSAQB needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 37 dBA; avoid mounting SANCO2 GS5-45HPC HP + ECO-83SSAQB directly beside quiet bedrooms.
- Requires condensate drain routing and 230V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing SANCO2 GS5-45HPC HP + ECO-83SSAQB** Strong Fit — 3.8 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare A. O. Smith HPS10-80H45DV 2** footprint.

## Common Homeowner Questions for SANCO2 GS5-45HPC HP + ECO-83SSAQB

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Does SANCO2 GS5-45HPC HP + ECO-83SSAQB pass the May 6, 2029 federal DOE efficiency rule?

SANCO2 GS5-45HPC HP + ECO-83SSAQB carries a verified 3.8 UEF rating (Pass: +1.30 / +52.0%), ranking #268 of 706 (top 41.9%) across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.

### What doorway width and ceiling height does SANCO2 GS5-45HPC HP + ECO-83SSAQB need?

SANCO2 GS5-45HPC HP + ECO-83SSAQB mounts as a hybrid/electric heat pump without a bulky floor tank (wall-hung / compact envelope). Verify vent termination distances and combustion air clearances per IPC or UPC.

### What gas pipe size or electrical breaker does SANCO2 GS5-45HPC HP + ECO-83SSAQB require?

SANCO2 GS5-45HPC HP + ECO-83SSAQB uses a 230V branch circuit at 7A max (Verify rating plate electrical draw). Verify main breaker space before replacing a gas tank with an electric hybrid unit.

### How much electricity or energy does SANCO2 GS5-45HPC HP + ECO-83SSAQB cost per year to run?

Rated at 1,313 kWh/yr, SANCO2 GS5-45HPC HP + ECO-83SSAQB costs about $238/yr ($2,380 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $192/yr in Washington hydro tiers up to $619/yr in Hawaii).

### Who should NOT install SANCO2 GS5-45HPC HP + ECO-83SSAQB, and what are its limits?

SANCO2 GS5-45HPC HP + ECO-83SSAQB (3.8 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 37 dBA.

### How many bathrooms or people can SANCO2 GS5-45HPC HP + ECO-83SSAQB serve at peak demand?

SANCO2 GS5-45HPC HP + ECO-83SSAQB achieves a 121 gal First Hour Rating (+49 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.

### Are there CPSC safety recalls or serial checks for SANCO2 GS5-45HPC HP + ECO-83SSAQB?

No active CPSC recalls matched SANCO2 as of 2026-11-23. Always decode the serial tag on SANCO2 GS5-45HPC HP + ECO-83SSAQB because OEM tank/exchanger warranties span 6–12 years.

### What 2026 rebates apply to SANCO2 GS5-45HPC HP + ECO-83SSAQB, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPS10-80H45DV 2** (3.88 UEF).

## Next Engineering Checks for SANCO2 Owners

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare A. O. Smith HPS10-80H45DV 2** (3.88 UEF)→](https://gcsradheat.com/water-heaters/a-o-smith/hps10-80h45dv-2/)
- [Compare American HPS10280H045DV 2** (3.88 UEF)→](https://gcsradheat.com/water-heaters/american/hps10280h045dv-2/)
- [View All SANCO2 Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/sanco2/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)