# Smart Solar SSG2-ES 120 Water Heater Specifications (2.85 UEF)

Engineered as a Electric Hybrid/Electric Heat Pump unit, Smart Solar SSG2-ES 120 achieves a certified 2.85 UEF rating across its 120-gallon nominal tank, 83 gal First Hour Rating and ranks #694 of 706 in its 706-model cohort (PD 3387677), recording Pass: +0.35 / +14.0% under 2029 DOE rules. Rated annual electricity draw of 1,741 kWh/yr equates to roughly $316/yr ($3,162 over 10 years) at 18.16 cents/kWh. Closest certified alternative is VAUGHN THERMAL MP120FHPT (3.5 UEF).

- **Uniform Energy Factor**: 2.85 UEF

- **Cohort UEF Rank**: #694 of 706

- **First Hour Rating**: 83 gal

- **Storage Volume**: 120 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +0.35 / +14.0%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Smart Solar SSG2-ES 120 relative to the cohort median.

Efficiency comparison & rule summary

Within the 706-unit Hybrid/Electric Heat Pump cohort, Smart Solar SSG2-ES 120 logs 2.85 UEF and ranks #694 of 706.

Against 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF), Smart Solar SSG2-ES 120 holds a +0.35 UEF (+14.0%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 1,741 kWh/yr for Smart Solar SSG2-ES 120 runs ~$316/yr vs. ~$979/yr for a 0.92 UEF electric tank.

State electric sensitivity for Smart Solar SSG2-ES 120: 10-year operating spend spans $2,547 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $8,214 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Cross-shopping Smart Solar SSG2-ES 120 (2.85 UEF)? Check VAUGHN THERMAL MP120FHPT (3.5 UEF, delta +0.65) and SANCO2 GS5-45HPC-D HP + ECO-119GLBK (3.72 UEF, delta +0.87).

## Where Does Smart Solar SSG2-ES 120 Rank Against Peer Hybrid/Electric Heat Pump Units?

Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, Smart Solar SSG2-ES 120 holds #694 of 706; inspect footprint, circuit load, and efficiency deltas here.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Smart Solar](https://gcsradheat.com/brands/smart-solar/) | 3 certified listings | ENERGY STAR PD 3387677 |
| Model Number | SSG2-ES 120 | Draw pattern: High-Usage | SSG2-ES 120 |
| Uniform Energy Factor (UEF) | 2.85 | -0.85 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 83 gal | +11 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,741 kWh/yr | +669 kWh/yr vs. 1,072 kWh/yr median | Est. $316/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 287% | -142.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 64" H x 28" D | Fits standard 72 in. basement/garage clearance; tight at 28 in. door (28" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 120 V / 8 A max | 120V plug-in retrofit circuit; slower heat-pump-only recovery | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2024-01-23 | Certified 2024-01-23 | Markets: United States, Canada |

## How Much Electricity Does SSG2-ES 120 Use in Different States?

Estimated at $316/yr nationally (1,741 kWh/yr), 10-year utility spending for Smart Solar SSG2-ES 120 shifts sharply between low-rate hydro and coastal grids.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $316/yr | $3,162 | $6,632 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $821/yr | $8,214 | $17,230 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $518/yr | $5,179 | $10,865 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $277/yr | $2,770 | $5,810 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $255/yr | $2,547 | $5,343 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (1,741 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Does CPSC Flag Any Safety Notices on Smart Solar Units?

No open CPSC recall alerts appeared for Smart Solar as of 2026-11-23; you can still decode exact manufacture month and warranty window below. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## Which Competing Hybrid/Electric Heat Pump Models Compare Closest to SSG2-ES 120?

Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to Smart Solar SSG2-ES 120's gallon capacity and 2.85 UEF efficiency.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [VAUGHN THERMAL MP120FHPT](https://gcsradheat.com/water-heaters/vaughn-thermal/mp120fhpt/) | Hybrid/Electric Heat Pump | 119 gal | 115 gal | 3.5 (+0.65) | 1,418 |
| [SANCO2 GS5-45HPC-D HP + ECO-119GLBK](https://gcsradheat.com/water-heaters/sanco2/gs5-45hpc-d-hp-eco-119glbk/) | Hybrid/Electric Heat Pump | 119 gal | 134 gal | 3.72 (+0.87) | 1,333 |
| [Reclaim Energy MP120F-RC](https://gcsradheat.com/water-heaters/reclaim-energy/mp120f-rc/) | Hybrid/Electric Heat Pump | 119 gal | 121 gal | 3.75 (+0.90) | 1,296 |
| [Hubbell ME120HPT](https://gcsradheat.com/water-heaters/hubbell/me120hpt/) | Hybrid/Electric Heat Pump | 109 gal | 105 gal | 3.38 (+0.53) | 1,467 |
| [SANCO2 GS5-45HPC HP + ECO-119GLBK](https://gcsradheat.com/water-heaters/sanco2/gs5-45hpc-hp-eco-119glbk/) | Hybrid/Electric Heat Pump | 119 gal | 134 gal | 3.72 (+0.87) | 1,333 |

## When Should Homeowners Skip Smart Solar SSG2-ES 120 (Hybrid/Electric Heat Pump)?

Check Smart Solar SSG2-ES 120's mechanical constraints—including utility space, Electric capacity, and Pass: +0.35 / +14.0% status—against typical residential installations.

### Key Limitations & Exclusions

- Smart Solar SSG2-ES 120 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Smart Solar SSG2-ES 120 directly beside quiet bedrooms.
- Requires condensate drain routing and 120V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing Smart Solar SSG2-ES 120** Strong Fit — 2.85 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare VAUGHN THERMAL MP120FHPT footprint.

## Common Homeowner Questions for Smart Solar SSG2-ES 120

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Will Smart Solar SSG2-ES 120 stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 2.85 UEF, Smart Solar SSG2-ES 120 shows Pass: +0.35 / +14.0% relative to May 6, 2029 federal DOE limits while placing #694 of 706 among 706 Hybrid/Electric Heat Pump peers like VAUGHN THERMAL MP120FHPT.

### Will Smart Solar SSG2-ES 120 fit through a standard utility door and 72-inch basement ceiling?

Measuring 64 in. tall by 28 in. diameter, Smart Solar SSG2-ES 120 notes: fits standard 72 in. basement/garage clearance; tight at 28 in. door (28" d). Reserve space above the jacket for T&P piping and anode removal.

### Do existing utility hookups support Smart Solar SSG2-ES 120 during replacement?

Electrical specs for Smart Solar SSG2-ES 120 call for 120V at 8A max (120V plug-in retrofit circuit; slower heat-pump-only recovery). Have a licensed electrician inspect panel load and wire gauge.

### What is the estimated 10-year operating spend for Smart Solar SSG2-ES 120?

At 18.16 cents/kWh national residential pricing, Smart Solar SSG2-ES 120's 1,741 kWh/yr draw equals roughly $316 annually or $3,160 across a 10-year horizon (ranging from $255/yr in Washington hydro tiers up to $821/yr in Hawaii).

### When is Smart Solar SSG2-ES 120 a poor fit for a residential replacement?

Avoid placing Smart Solar SSG2-ES 120 directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.

### What First Hour Rating or flow capacity does Smart Solar SSG2-ES 120 deliver?

With 83 gal FHR (+11 gal vs. 72 gal median), Smart Solar SSG2-ES 120 fits larger 3–5 person homes cleanly.

### How do you verify manufacturing age and recall status on Smart Solar SSG2-ES 120?

Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for Smart Solar; verify exact manufacturing week for Smart Solar SSG2-ES 120 using the Serial Number Lookup tool.

### Does Smart Solar SSG2-ES 120 qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Smart Solar SSG2-ES 120. Closest peer in Hybrid/Electric Heat Pump is VAUGHN THERMAL MP120FHPT (3.5 UEF).

## Next Engineering Checks for Smart Solar Owners

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare VAUGHN THERMAL MP120FHPT (3.5 UEF)→](https://gcsradheat.com/water-heaters/vaughn-thermal/mp120fhpt/)
- [Compare SANCO2 GS5-45HPC-D HP + ECO-119GLBK (3.72 UEF)→](https://gcsradheat.com/water-heaters/sanco2/gs5-45hpc-d-hp-eco-119glbk/)
- [View All Smart Solar Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/smart-solar/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.