title: "State GP-8-75-*TPDT 4** (0.86 UEF, 74 gal)"
url: https://gcsradheat.com/water-heaters/state/gp-8-75-tpdt-4/
description: "Certified at 0.86 UEF across its 74-gallon nominal tank, 150 gal First Hour Rating, State GP-8-75-*TPDT 4** (Gas-fired Storage Residential-duty Commercial."
---

ENERGY STAR water heater model · PD 4518076

# State GP-8-75-*TPDT 4** Water Heater Specifications (0.86 UEF)

Certified at 0.86 UEF across its 74-gallon nominal tank, 150 gal First Hour Rating, State GP-8-75-*TPDT 4** (Gas-fired Storage Residential-duty Commercial, Natural Gas, Propane) places #62 of 71 out of 71 ENERGY STAR models (PD 4518076). Its May 6, 2029 10 CFR 430.32 status reads Pass: +0.28 / +48.3%. Annual fuel cost depends on regional gas/fuel tariffs and fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.5" d). Closest certified alternative is A. O. Smith HDHE-75 4** (0.86 UEF).

- **Uniform Energy Factor**: 0.86 UEF

- **Cohort UEF Rank**: #62 of 71

- **First Hour Rating**: 150 gal

- **Storage Volume**: 74 gal

- **Fuel / Type**: Natural Gas, Propane / Gas-fired Storage Residential-duty Commercial

- **DOE 2029 Rule Status**: Pass: +0.28 / +48.3%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Gas-fired Storage Residential-duty Commercial UEF Efficiency Distribution (71 Certified Units). Highlighted pin shows State GP-8-75-*TPDT 4** relative to the cohort median.

Efficiency comparison & rule summary

Tested at 0.86 UEF, State GP-8-75-*TPDT 4** places #62 of 71 across 71 certified Gas-fired Storage Residential-duty Commercial configurations (-0.02 UEF vs. 0.88 UEF median).

State gp-8-75-*tpdt 4** stores 74 gal nominal; 150 gal first hour rating (+14 gal vs. 136 gal median); fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.5" d).

Closest alternatives to State GP-8-75-*TPDT 4** include A. O. Smith HDHE-75 4** (0.86 UEF, at parity) alongside American VG8275T100*V (0.86 UEF, at parity).

## Which Specs Set State GP-8-75-*TPDT 4** Apart From Cohort Averages?

Ranked #62 of 71 inside the 71-model Gas-fired Storage Residential-duty Commercial cohort, State GP-8-75-*TPDT 4** is evaluated row by row below against category medians.

Certified model attributes compared against 71 ENERGY STAR Gas-fired Storage Residential-duty Commercial peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [State](https://gcsradheat.com/brands/state/) | 81 certified listings | ENERGY STAR PD 4518076 |
| Model Number | GP-8-75-*TPDT 4** | Draw pattern: High-Usage | GP-8-75-*TPDT 4** |
| Uniform Energy Factor (UEF) | 0.86 | -0.02 UEF vs. 0.88 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 150 gal | +14 gal vs. 136 gal median | 10 CFR 430 Recovery Test |
| Thermal Recovery Efficiency | 97% | +2.0 pts vs. 95.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 51.9" H x 22.5" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.5" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 5 A max | 120V AC ignition/fan + gas piping check | NEC / Branch circuit check |
| Certification Date | 2025-12-12 | Certified 2025-12-12 | Markets: United States |

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## What Should State Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC SaferProducts snapshot includes 4 filings tied to State; verify whether your GP-8-75-*TPDT 4** production run falls inside affected ranges. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

**4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range**

- **Recall #19029 (2018-11-08):** A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard ([CPSC Notice](https://www.cpsc.gov/Recalls/2019/A-O-Smith-Recalls-Ultra-Low-NOx-Water-Heaters-Due-to-Fire-Hazard))
- **Recall #08241 (2008-04-03):** A.O. Smith Recalls Gas Water Heaters Due to Fire and Carbon Monoxide Hazards ([CPSC Notice](https://www.cpsc.gov/Recalls/2008/AO-Smith-Recalls-Gas-Water-Heaters-Due-to-Fire-and-Carbon-Monoxide-Hazards))
- **Recall #06002 (2005-10-06):** CPSC, A.O. Smith Announce Recall of Water Heaters ([CPSC Notice](https://www.cpsc.gov/Recalls/2006/CPSC-AO-Smith-Recall-of-Water-Heaters))
- **Recall #04128 (2004-04-28):** CPSC, White-Rodgers Announce Recall of LP and Convertible Gas Water Heater Temperature Controls ([CPSC Notice](https://www.cpsc.gov/Recalls/2004/CPSC-White-Rodgers-Announce-Recall-of-LP-and-Convertible-Gas-Water-Heater-Temperature-Controls-))

## How Do Five Nearby Gas-fired Storage Residential-duty Commercial Models Stack Up?

Five alternative Gas-fired Storage Residential-duty Commercial units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [A. O. Smith HDHE-75 4**](https://gcsradheat.com/water-heaters/a-o-smith/hdhe-75-4/) | Gas-fired Storage Residential-duty Commercial | 74 gal | 150 gal | 0.86 (at parity) | — |
| [American VG8275T100*V](https://gcsradheat.com/water-heaters/american/vg8275t100-v/) | Gas-fired Storage Residential-duty Commercial | 74 gal | 150 gal | 0.86 (at parity) | — |
| [GSW WATER HEATERS 8G-75100*PDV-H06* 4**](https://gcsradheat.com/water-heaters/gsw-water-heaters/8g-75100-pdv-h06-4/) | Gas-fired Storage Residential-duty Commercial | 74 gal | 150 gal | 0.86 (at parity) | — |
| [RELIANCE WATER HEATERS 8-75-*TPDT 4**](https://gcsradheat.com/water-heaters/reliance-water-heaters/8-75-tpdt-4/) | Gas-fired Storage Residential-duty Commercial | 74 gal | 150 gal | 0.86 (at parity) | — |
| [A. O. Smith GDHE-75 3**](https://gcsradheat.com/water-heaters/a-o-smith/gdhe-75-3/) | Gas-fired Storage Residential-duty Commercial | 74 gal | 130 gal | 0.86 (at parity) | — |

## What Are the Limitations of State GP-8-75-*TPDT 4** and Who Should Not Install It?

Before ordering State GP-8-75-*TPDT 4** (Gas-fired Storage Residential-duty Commercial, 0.86 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.

### Key Limitations & Exclusions

- State GP-8-75-*TPDT 4** logs 0.86 UEF (Pass: +0.28 / +48.3%); check May 6, 2029 10 CFR 430.32 transition status.
- Drain tank sediment yearly and inspect State GP-8-75-*TPDT 4**'s sacrificial anode rod every 4–6 years.
- Peak simultaneous draws exceeding 150 gal will deplete stored recovery capacity.

### Which Option Fits Your Situation?

**Direct Footprint Replacement for State GP-8-75-*TPDT 4 Strong Fit — Matches existing plumbing and vent clearances.

**2026 Post-OBBBA Rebate Buyers** Verify Tier — DOE HEAR ($1,750 max) targets >=2.30 UEF heat pump models like A. O. Smith HDHE-75 4**.

**Very Hard Well Water (>10.5 GPG)** Add Softener / Flush — Schedule 6-month tank sediment drains.

## Frequently Asked Technical Questions: State GP-8-75-*TPDT 4**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Does State GP-8-75-*TPDT 4** pass the May 6, 2029 federal DOE efficiency rule?

State GP-8-75-*TPDT 4** carries a verified 0.86 UEF rating (Pass: +0.28 / +48.3%), ranking #62 of 71 across 71 ENERGY STAR Gas-fired Storage Residential-duty Commercial models under 10 CFR 430.32.

### What doorway width and ceiling height does State GP-8-75-*TPDT 4** need?

State GP-8-75-*TPDT 4** stands 51.9 in. high with a 22.5 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.5" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.

### What gas pipe size or electrical breaker does State GP-8-75-*TPDT 4** require?

State GP-8-75-*TPDT 4** runs on Natural Gas, Propane (120V AC ignition/fan + gas piping check). Upgrading from a 40K tank to 199K BTU/h tankless demand requires checking IFGC Table 402.4(2), since 1/2 in. iron pipe drops below 199 CFH past 10 ft.

### How much electricity or energy does State GP-8-75-*TPDT 4** cost per year to run?

ENERGY STAR rates State GP-8-75-*TPDT 4** as a Natural Gas, Propane heater (0.86 UEF) without an electric kWh figure; annual fuel spend depends on local therm rates and Gas-fired Storage Residential-duty Commercial draw.

### Who should NOT install State GP-8-75-*TPDT 4**, and what are its limits?

State GP-8-75-*TPDT 4** (0.86 UEF) is not suited for multi-bath marathon draws exceeding its 150 gal capacity or buyers prioritizing May 6, 2029 high-UEF HPWH rebates.

### How many bathrooms or people can State GP-8-75-*TPDT 4** serve at peak demand?

State GP-8-75-*TPDT 4** achieves a 150 gal First Hour Rating (+14 gal vs. 136 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.

### Are there CPSC safety recalls or serial checks for State GP-8-75-*TPDT 4**?

CPSC SaferProducts records show 4 brand-level recall notices mentioning State as of 2026-11-23, including #19029 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

### What 2026 rebates apply to State GP-8-75-*TPDT 4**, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Gas-fired Storage Residential-duty Commercial is A. O. Smith HDHE-75 4** (0.86 UEF).

## Essential Pre-Install Guides for State GP-8-75-*TPDT 4**

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare A. O. Smith HDHE-75 4** (0.86 UEF)→](https://gcsradheat.com/water-heaters/a-o-smith/hdhe-75-4/)
- [Compare American VG8275T100*V (0.86 UEF)→](https://gcsradheat.com/water-heaters/american/vg8275t100-v/)
- [View All State Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/state/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm gas pipe length and CFH capacity (especially 199,000 BTU/h condensing tankless conversions under IFGC Table 402.4) and decode the old unit's serial plate.
[Verify Gas Line (IFGC)](https://gcsradheat.com/tools/gas-pipe-sizing-calculator/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)