title: "State GP6-50-*TPDT 3** (0.88 UEF, 49 gal)"
url: https://gcsradheat.com/water-heaters/state/gp6-50-tpdt-3/
description: "In the 71-unit Gas-fired Storage Residential-duty Commercial class, State GP6-50-*TPDT 3** (Natural Gas, Propane) achieves a certified 0.88 UEF rating across."
---

ENERGY STAR water heater model · PD 2408819

# State GP6-50-*TPDT 3** Water Heater Specifications (0.88 UEF)

In the 71-unit Gas-fired Storage Residential-duty Commercial class, State GP6-50-*TPDT 3** (Natural Gas, Propane) achieves a certified 0.88 UEF rating across its 49-gallon nominal tank, 100 gal First Hour Rating (rank #34 of 71, PD 2408819) and verifies as Pass: +0.30 / +51.7% for 2029 DOE floors. Annual fuel cost depends on regional gas/fuel tariffs and fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18" d). Closest certified alternative is A. O. Smith GDHE-50 3** (0.88 UEF).

- **Uniform Energy Factor**: 0.88 UEF

- **Cohort UEF Rank**: #34 of 71

- **First Hour Rating**: 100 gal

- **Storage Volume**: 49 gal

- **Fuel / Type**: Natural Gas, Propane / Gas-fired Storage Residential-duty Commercial

- **DOE 2029 Rule Status**: Pass: +0.30 / +51.7%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Gas-fired Storage Residential-duty Commercial UEF Efficiency Distribution (71 Certified Units). Highlighted pin shows State GP6-50-*TPDT 3** relative to the cohort median.

Efficiency comparison & rule summary

State GP6-50-*TPDT 3** records 0.88 UEF efficiency, putting it #34 of 71 among 71 Gas-fired Storage Residential-duty Commercial peers.

State gp6-50-*tpdt 3** stores 49 gal nominal; 100 gal first hour rating (-36 gal vs. 136 gal median); fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18" d).

Competing options beside State GP6-50-*TPDT 3** (0.88 UEF) are A. O. Smith GDHE-50 3** (0.88 UEF, at parity) and American VG6250T100*V 3** (0.88 UEF, at parity).

## How Do State GP6-50-*TPDT 3** Specs Compare to Gas-fired Storage Residential-duty Commercial Medians?

State GP6-50-*TPDT 3** places #34 of 71 across 71 certified Gas-fired Storage Residential-duty Commercial configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 71 ENERGY STAR Gas-fired Storage Residential-duty Commercial peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [State](https://gcsradheat.com/brands/state/) | 81 certified listings | ENERGY STAR PD 2408819 |
| Model Number | GP6-50-*TPDT 3** | Draw pattern: High-Usage | GP6-50-*TPDT 3** |
| Uniform Energy Factor (UEF) | 0.88 | At 0.88 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 100 gal | -36 gal vs. 136 gal median | 10 CFR 430 Recovery Test |
| Thermal Recovery Efficiency | 95% | At 95.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 55.7" H x 18" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 5 A max | 120V AC ignition/fan + gas piping check | NEC / Branch circuit check |
| Certification Date | 2023-02-23 | Certified 2023-02-23 | Markets: United States |

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Are There Active CPSC Safety Recalls for State Water Heaters?

Our 2026-11-23 CPSC SaferProducts query surfaced 4 brand-level recall notices associated with State; match your serial plate before repair. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

**4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range**

- **Recall #19029 (2018-11-08):** A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard ([CPSC Notice](https://www.cpsc.gov/Recalls/2019/A-O-Smith-Recalls-Ultra-Low-NOx-Water-Heaters-Due-to-Fire-Hazard))
- **Recall #08241 (2008-04-03):** A.O. Smith Recalls Gas Water Heaters Due to Fire and Carbon Monoxide Hazards ([CPSC Notice](https://www.cpsc.gov/Recalls/2008/AO-Smith-Recalls-Gas-Water-Heaters-Due-to-Fire-and-Carbon-Monoxide-Hazards))
- **Recall #06002 (2005-10-06):** CPSC, A.O. Smith Announce Recall of Water Heaters ([CPSC Notice](https://www.cpsc.gov/Recalls/2006/CPSC-AO-Smith-Recall-of-Water-Heaters))
- **Recall #04128 (2004-04-28):** CPSC, White-Rodgers Announce Recall of LP and Convertible Gas Water Heater Temperature Controls ([CPSC Notice](https://www.cpsc.gov/Recalls/2004/CPSC-White-Rodgers-Announce-Recall-of-LP-and-Convertible-Gas-Water-Heater-Temperature-Controls-))

## Which Certified Water Heaters Match GP6-50-*TPDT 3** Most Closely?

These 5 competing Gas-fired Storage Residential-duty Commercial units sit nearest to State GP6-50-*TPDT 3** by storage capacity and 0.88 UEF rating.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [A. O. Smith GDHE-50 3**](https://gcsradheat.com/water-heaters/a-o-smith/gdhe-50-3/) | Gas-fired Storage Residential-duty Commercial | 49 gal | 100 gal | 0.88 (at parity) | — |
| [American VG6250T100*V 3**](https://gcsradheat.com/water-heaters/american/vg6250t100-v-3/) | Gas-fired Storage Residential-duty Commercial | 49 gal | 100 gal | 0.88 (at parity) | — |
| [GSW WATER HEATERS 6G50100*PDVH 3**](https://gcsradheat.com/water-heaters/gsw-water-heaters/6g50100-pdvh-3/) | Gas-fired Storage Residential-duty Commercial | 49 gal | 100 gal | 0.88 (at parity) | — |
| [RELIANCE WATER HEATERS 6-50-*TPDT 3**](https://gcsradheat.com/water-heaters/reliance-water-heaters/6-50-tpdt-3/) | Gas-fired Storage Residential-duty Commercial | 49 gal | 100 gal | 0.88 (at parity) | — |
| [A. O. Smith HDHE-50 4**](https://gcsradheat.com/water-heaters/a-o-smith/hdhe-50-4/) | Gas-fired Storage Residential-duty Commercial | 49 gal | 118 gal | 0.88 (at parity) | — |

## Who Is State GP6-50-*TPDT 3** Best For — and When Should You Pick A. O. Smith GDHE-50 3**?

Evaluate whether State GP6-50-*TPDT 3**'s Gas-fired Storage Residential-duty Commercial architecture matches your existing mechanical room and local utility tariffs before purchasing.

### Key Limitations & Exclusions

- State GP6-50-*TPDT 3** logs 0.88 UEF (Pass: +0.30 / +51.7%); check May 6, 2029 10 CFR 430.32 transition status.
- Drain tank sediment yearly and inspect State GP6-50-*TPDT 3**'s sacrificial anode rod every 4–6 years.
- Peak simultaneous draws exceeding 100 gal will deplete stored recovery capacity.

### Which Option Fits Your Situation?

**Direct Footprint Replacement for State GP6-50-*TPDT 3 Strong Fit — Matches existing plumbing and vent clearances.

**2026 Post-OBBBA Rebate Buyers** Verify Tier — DOE HEAR ($1,750 max) targets >=2.30 UEF heat pump models like A. O. Smith GDHE-50 3**.

**Very Hard Well Water (>10.5 GPG)** Add Softener / Flush — Schedule 6-month tank sediment drains.

## What Are the Key Questions About State GP6-50-*TPDT 3**?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### How does State GP6-50-*TPDT 3** (0.88 UEF) compare to 2029 federal DOE floors?

Evaluated against May 6, 2029 10 CFR 430.32 thresholds, State GP6-50-*TPDT 3** records 0.88 UEF (Pass: +0.30 / +51.7%), placing #34 of 71 out of 71 certified Gas-fired Storage Residential-duty Commercial configurations.

### Does State GP6-50-*TPDT 3** fit inside a tight hallway closet or low-headroom utility room?

State GP6-50-*TPDT 3** requires room for its 55.7 in. vertical shell and 18 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18" d)), plus service access for annual sediment draining.

### What power supply or fuel line specs govern State GP6-50-*TPDT 3**?

Installing State GP6-50-*TPDT 3** on Natural Gas, Propane involves 120V AC ignition/fan + gas piping check. Verify regulator capacity and dedicated Category IV PVC venting rather than reusing legacy galvanized flues.

### What annual utility bill should homeowners budget for State GP6-50-*TPDT 3**?

Rated 0.88 UEF on Natural Gas, Propane, State GP6-50-*TPDT 3** carries no whole-house kWh heating draw; confirm annual therm usage against 71 Gas-fired Storage Residential-duty Commercial models.

### What are the main drawbacks of State GP6-50-*TPDT 3** (0.88 UEF)?

Buyers expecting endless simultaneous shower flow beyond 100 gal should compare condensing tankless units or larger-capacity tanks.

### What hot-water delivery rating governs State GP6-50-*TPDT 3**?

Rated for 100 gal FHR (-36 gal vs. 136 gal median), State GP6-50-*TPDT 3** prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.

### Where do homeowners screen State GP6-50-*TPDT 3** for recalls and tank age?

CPSC SaferProducts records show 4 brand-level recall notices mentioning State as of 2026-11-23, including #19029 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

### What alternative models sit closest to State GP6-50-*TPDT 3** in the Gas-fired Storage Residential-duty Commercial class?

Closest peer in Gas-fired Storage Residential-duty Commercial is A. O. Smith GDHE-50 3** (0.88 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

## Which Sizing and Compliance Guides Pair with GP6-50-*TPDT 3**?

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare A. O. Smith GDHE-50 3** (0.88 UEF)→](https://gcsradheat.com/water-heaters/a-o-smith/gdhe-50-3/)
- [Compare American VG6250T100*V 3** (0.88 UEF)→](https://gcsradheat.com/water-heaters/american/vg6250t100-v-3/)
- [View All State Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/state/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm gas pipe length and CFH capacity (especially 199,000 BTU/h condensing tankless conversions under IFGC Table 402.4) and decode the old unit's serial plate.
[Verify Gas Line (IFGC)](https://gcsradheat.com/tools/gas-pipe-sizing-calculator/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)