title: "State GP8-40-YRPCSL 1** (0.9 UEF, 38 gal)"
url: https://gcsradheat.com/water-heaters/state/gp8-40-yrpcsl-1/
description: "Engineered as a Natural Gas, Propane Gas Storage unit, State GP8-40-YRPCSL 1** achieves a certified 0.9 UEF rating across its 38-gallon nominal tank, 86 gal."
---

ENERGY STAR water heater model · PD 3798672

# State GP8-40-YRPCSL 1** Water Heater Specifications (0.9 UEF)

Engineered as a Natural Gas, Propane Gas Storage unit, State GP8-40-YRPCSL 1** achieves a certified 0.9 UEF rating across its 38-gallon nominal tank, 86 gal First Hour Rating and ranks #1 of 71 in its 71-model cohort (PD 3798672), recording Pass: +0.32 / +55.2% under 2029 DOE rules. Annual fuel cost depends on regional gas/fuel tariffs and fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" d). Closest certified alternative is A. O. Smith GC6-PS4050*V 1** (0.9 UEF).

- **Uniform Energy Factor**: 0.9 UEF

- **Cohort UEF Rank**: #1 of 71

- **First Hour Rating**: 86 gal

- **Storage Volume**: 38 gal

- **Fuel / Type**: Natural Gas, Propane / Gas Storage

- **DOE 2029 Rule Status**: Pass: +0.32 / +55.2%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Gas Storage UEF Efficiency Distribution (71 Certified Units). Highlighted pin shows State GP8-40-YRPCSL 1** relative to the cohort median.

Efficiency comparison & rule summary

Within the 71-unit Gas Storage cohort, State GP8-40-YRPCSL 1** logs 0.9 UEF and ranks #1 of 71.

State gp8-40-yrpcsl 1** stores 38 gal nominal; 86 gal first hour rating (-9 gal vs. 95 gal median); fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" d).

Cross-shopping State GP8-40-YRPCSL 1** (0.9 UEF)? Check A. O. Smith GC6-PS4050*V 1** (0.9 UEF, at parity) and American PCG62-40S50L 1** (0.9 UEF, at parity).

## How Complete Are the Certified Metrics for State GP8-40-YRPCSL 1**?

Standing at #1 of 71 among 71 certified Gas Storage heaters, State GP8-40-YRPCSL 1** brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 71 ENERGY STAR Gas Storage peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [State](https://gcsradheat.com/brands/state/) | 81 certified listings | ENERGY STAR PD 3798672 |
| Model Number | GP8-40-YRPCSL 1** | Draw pattern: High-Usage | GP8-40-YRPCSL 1** |
| Uniform Energy Factor (UEF) | 0.9 | At 0.90 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 86 gal | -9 gal vs. 95 gal median | 10 CFR 430 Recovery Test |
| Thermal Recovery Efficiency | 91% | -3.0 pts vs. 94.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 44.7" H x 22" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 2 A max | 120V AC ignition/fan + gas piping check | NEC / Branch circuit check |
| Certification Date | 2024-11-13 | Certified 2024-11-13 | Markets: United States, Canada |

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Are State Models Affected by Current CPSC Notices?

Review 4 brand-matched CPSC entries pulled 2026-11-23 for State and confirm your serial tag before scheduling contractor service. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

**4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range**

- **Recall #19029 (2018-11-08):** A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard ([CPSC Notice](https://www.cpsc.gov/Recalls/2019/A-O-Smith-Recalls-Ultra-Low-NOx-Water-Heaters-Due-to-Fire-Hazard))
- **Recall #08241 (2008-04-03):** A.O. Smith Recalls Gas Water Heaters Due to Fire and Carbon Monoxide Hazards ([CPSC Notice](https://www.cpsc.gov/Recalls/2008/AO-Smith-Recalls-Gas-Water-Heaters-Due-to-Fire-and-Carbon-Monoxide-Hazards))
- **Recall #06002 (2005-10-06):** CPSC, A.O. Smith Announce Recall of Water Heaters ([CPSC Notice](https://www.cpsc.gov/Recalls/2006/CPSC-AO-Smith-Recall-of-Water-Heaters))
- **Recall #04128 (2004-04-28):** CPSC, White-Rodgers Announce Recall of LP and Convertible Gas Water Heater Temperature Controls ([CPSC Notice](https://www.cpsc.gov/Recalls/2004/CPSC-White-Rodgers-Announce-Recall-of-LP-and-Convertible-Gas-Water-Heater-Temperature-Controls-))

## Which 5 Models Offer Similar Output to GP8-40-YRPCSL 1**?

Ordered by minimal capacity and UEF spread relative to State GP8-40-YRPCSL 1**, these five certified peers give direct replacement benchmarks.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [A. O. Smith GC6-PS4050*V 1**](https://gcsradheat.com/water-heaters/a-o-smith/gc6-ps4050-v-1/) | Gas Storage | 38 gal | 86 gal | 0.9 (at parity) | — |
| [American PCG62-40S50L 1**](https://gcsradheat.com/water-heaters/american/pcg62-40s50l-1/) | Gas Storage | 38 gal | 86 gal | 0.9 (at parity) | — |
| [Envirosense Enercare ENV-40N-ENER 1**](https://gcsradheat.com/water-heaters/envirosense-enercare/env-40n-ener-1/) | Gas Storage | 38 gal | 86 gal | 0.9 (at parity) | — |
| [Envirosense Reliance Home Comfort ENV-40N-RHC 1**](https://gcsradheat.com/water-heaters/envirosense-reliance-home-comfort/env-40n-rhc-1/) | Gas Storage | 38 gal | 86 gal | 0.9 (at parity) | — |
| [A. O. Smith GC9-PS4050NV 1**](https://gcsradheat.com/water-heaters/a-o-smith/gc9-ps4050nv-1/) | Gas Storage | 38 gal | 86 gal | 0.9 (at parity) | — |

## What Are the Limitations of State GP8-40-YRPCSL 1** and Who Should Not Install It?

Before ordering State GP8-40-YRPCSL 1** (Gas Storage, 0.9 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.

### Key Limitations & Exclusions

- State GP8-40-YRPCSL 1** logs 0.9 UEF (Pass: +0.32 / +55.2%); check May 6, 2029 10 CFR 430.32 transition status.
- Drain tank sediment yearly and inspect State GP8-40-YRPCSL 1**'s sacrificial anode rod every 4–6 years.
- Peak simultaneous draws exceeding 86 gal will deplete stored recovery capacity.

### Which Option Fits Your Situation?

**Direct Footprint Replacement for State GP8-40-YRPCSL 1 Strong Fit — Matches existing plumbing and vent clearances.

**2026 Post-OBBBA Rebate Buyers** Verify Tier — DOE HEAR ($1,750 max) targets >=2.30 UEF heat pump models like A. O. Smith GC6-PS4050*V 1**.

**Very Hard Well Water (>10.5 GPG)** Add Softener / Flush — Schedule 6-month tank sediment drains.

## Practical Specs & Code Questions for State GP8-40-YRPCSL 1**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Does State GP8-40-YRPCSL 1** pass the May 6, 2029 federal DOE efficiency rule?

State GP8-40-YRPCSL 1** carries a verified 0.9 UEF rating (Pass: +0.32 / +55.2%), ranking #1 of 71 across 71 ENERGY STAR Gas Storage models under 10 CFR 430.32.

### What doorway width and ceiling height does State GP8-40-YRPCSL 1** need?

State GP8-40-YRPCSL 1** stands 44.7 in. high with a 22 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.

### What gas pipe size or electrical breaker does State GP8-40-YRPCSL 1** require?

State GP8-40-YRPCSL 1** runs on Natural Gas, Propane (120V AC ignition/fan + gas piping check). Upgrading from a 40K tank to 199K BTU/h tankless demand requires checking IFGC Table 402.4(2), since 1/2 in. iron pipe drops below 199 CFH past 10 ft.

### How much electricity or energy does State GP8-40-YRPCSL 1** cost per year to run?

ENERGY STAR rates State GP8-40-YRPCSL 1** as a Natural Gas, Propane heater (0.9 UEF) without an electric kWh figure; annual fuel spend depends on local therm rates and Gas Storage draw.

### Who should NOT install State GP8-40-YRPCSL 1**, and what are its limits?

State GP8-40-YRPCSL 1** (0.9 UEF) is not suited for multi-bath marathon draws exceeding its 86 gal capacity or buyers prioritizing May 6, 2029 high-UEF HPWH rebates.

### How many bathrooms or people can State GP8-40-YRPCSL 1** serve at peak demand?

State GP8-40-YRPCSL 1** achieves a 86 gal First Hour Rating (-9 gal vs. 95 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.

### Are there CPSC safety recalls or serial checks for State GP8-40-YRPCSL 1**?

CPSC SaferProducts records show 4 brand-level recall notices mentioning State as of 2026-11-23, including #19029 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

### What 2026 rebates apply to State GP8-40-YRPCSL 1**, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Gas Storage is A. O. Smith GC6-PS4050*V 1** (0.9 UEF).

## Installation, Serial & DOE 2029 Links for GP8-40-YRPCSL 1**

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare A. O. Smith GC6-PS4050*V 1** (0.9 UEF)→](https://gcsradheat.com/water-heaters/a-o-smith/gc6-ps4050-v-1/)
- [Compare American PCG62-40S50L 1** (0.9 UEF)→](https://gcsradheat.com/water-heaters/american/pcg62-40s50l-1/)
- [View All State Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/state/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm gas pipe length and CFH capacity (especially 199,000 BTU/h condensing tankless conversions under IFGC Table 402.4) and decode the old unit's serial plate.
[Verify Gas Line (IFGC)](https://gcsradheat.com/tools/gas-pipe-sizing-calculator/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)