title: "State HP6-50-DHPT 1** (3.35 UEF, 46 gal)"
url: https://gcsradheat.com/water-heaters/state/hp6-50-dhpt-1/
description: "With PD 2408908 certification, State HP6-50-DHPT 1** (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.35 UEF rating across its 46-gallon nominal."
---

ENERGY STAR water heater model · PD 2408908

# State HP6-50-DHPT 1** Water Heater Specifications (3.35 UEF)

With PD 2408908 certification, State HP6-50-DHPT 1** (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.35 UEF rating across its 46-gallon nominal tank, 66 gal First Hour Rating, standing #635 of 706 across 706 peers with Pass: +1.05 / +45.7% for May 6, 2029. Rated annual electricity draw of 970 kWh/yr equates to roughly $176/yr ($1,762 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith FPTU-50 1** (3.35 UEF).

- **Uniform Energy Factor**: 3.35 UEF

- **Cohort UEF Rank**: #635 of 706

- **First Hour Rating**: 66 gal

- **Storage Volume**: 46 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.05 / +45.7%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows State HP6-50-DHPT 1** relative to the cohort median.

Efficiency comparison & rule summary

ENERGY STAR certification places State HP6-50-DHPT 1** at 3.35 UEF (#635 of 706; -0.35 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.

May 6, 2029 readiness: State HP6-50-DHPT 1** stands +1.05 UEF (+45.7%) relative to 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 970 kWh/yr for State HP6-50-DHPT 1** runs ~$176/yr vs. ~$641/yr for a 0.92 UEF electric tank.

State electric sensitivity for State HP6-50-DHPT 1**: 10-year operating spend spans $1,419 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,576 in Hawaii (Highest EIA State) (47.18 cents/kWh).

In the Hybrid/Electric Heat Pump tier, A. O. Smith FPTU-50 1** (3.35 UEF, at parity) and American HPHE6250H045DV 1** (3.35 UEF, at parity) bracket State HP6-50-DHPT 1**.

## How Do State HP6-50-DHPT 1** Specs Compare to Hybrid/Electric Heat Pump Medians?

State HP6-50-DHPT 1** places #635 of 706 across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [State](https://gcsradheat.com/brands/state/) | 81 certified listings | ENERGY STAR PD 2408908 |
| Model Number | HP6-50-DHPT 1** | Draw pattern: Medium-Usage | HP6-50-DHPT 1** |
| Uniform Energy Factor (UEF) | 3.35 | -0.35 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 66 gal | -6 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 970 kWh/yr | -102 kWh/yr vs. 1,072 kWh/yr median | Est. $176/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 407% | -22.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 63" H x 15" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (15" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 22 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2023-02-23 | Certified 2023-02-23 | Markets: United States |

## What Does HP6-50-DHPT 1** Cost to Operate Across State Electricity Rates?

At 970 kWh/yr, State HP6-50-DHPT 1** runs roughly $176/yr on the EIA national average tier under August 2026 Table 5.6.A rates.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $176/yr | $1,762 | $4,653 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $458/yr | $4,576 | $12,088 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $289/yr | $2,886 | $7,622 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $154/yr | $1,543 | $4,076 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $142/yr | $1,419 | $3,748 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (970 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Are There Active CPSC Safety Recalls for State Water Heaters?

Our 2026-11-23 CPSC SaferProducts query surfaced 4 brand-level recall notices associated with State; match your serial plate before repair. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

**4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range**

- **Recall #19029 (2018-11-08):** A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard ([CPSC Notice](https://www.cpsc.gov/Recalls/2019/A-O-Smith-Recalls-Ultra-Low-NOx-Water-Heaters-Due-to-Fire-Hazard))
- **Recall #08241 (2008-04-03):** A.O. Smith Recalls Gas Water Heaters Due to Fire and Carbon Monoxide Hazards ([CPSC Notice](https://www.cpsc.gov/Recalls/2008/AO-Smith-Recalls-Gas-Water-Heaters-Due-to-Fire-and-Carbon-Monoxide-Hazards))
- **Recall #06002 (2005-10-06):** CPSC, A.O. Smith Announce Recall of Water Heaters ([CPSC Notice](https://www.cpsc.gov/Recalls/2006/CPSC-AO-Smith-Recall-of-Water-Heaters))
- **Recall #04128 (2004-04-28):** CPSC, White-Rodgers Announce Recall of LP and Convertible Gas Water Heater Temperature Controls ([CPSC Notice](https://www.cpsc.gov/Recalls/2004/CPSC-White-Rodgers-Announce-Recall-of-LP-and-Convertible-Gas-Water-Heater-Temperature-Controls-))

## Which Certified Water Heaters Match HP6-50-DHPT 1** Most Closely?

These 5 competing Hybrid/Electric Heat Pump units sit nearest to State HP6-50-DHPT 1** by storage capacity and 3.35 UEF rating.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [A. O. Smith FPTU-50 1**](https://gcsradheat.com/water-heaters/a-o-smith/fptu-50-1/) | Hybrid/Electric Heat Pump | 46 gal | 66 gal | 3.35 (at parity) | 970 |
| [American HPHE6250H045DV 1**](https://gcsradheat.com/water-heaters/american/hphe6250h045dv-1/) | Hybrid/Electric Heat Pump | 46 gal | 66 gal | 3.35 (at parity) | 970 |
| [RELIANCE WATER HEATERS 6-50-DHPHT 1**](https://gcsradheat.com/water-heaters/reliance-water-heaters/6-50-dhpht-1/) | Hybrid/Electric Heat Pump | 46 gal | 66 gal | 3.35 (at parity) | 970 |
| [U.S. Craftmaster HPHE2F50HD045VU 1**](https://gcsradheat.com/water-heaters/u-s-craftmaster/hphe2f50hd045vu-1/) | Hybrid/Electric Heat Pump | 46 gal | 66 gal | 3.35 (at parity) | 970 |
| [Eco-Logical OMNI-50HP1-1A](https://gcsradheat.com/water-heaters/eco-logical/omni-50hp1-1a/) | Hybrid/Electric Heat Pump | 46 gal | 50 gal | 3.3 (-0.05) | 681 |

## When Should Homeowners Skip State HP6-50-DHPT 1** (Hybrid/Electric Heat Pump)?

Check State HP6-50-DHPT 1**'s mechanical constraints—including utility space, Electric capacity, and Pass: +1.05 / +45.7% status—against typical residential installations.

### Key Limitations & Exclusions

- State HP6-50-DHPT 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting State HP6-50-DHPT 1** directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing State HP6-50-DHPT 1 Strong Fit — 3.35 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare A. O. Smith FPTU-50 1** footprint.

## What Are the Key Questions About State HP6-50-DHPT 1**?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Will State HP6-50-DHPT 1** stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 3.35 UEF, State HP6-50-DHPT 1** shows Pass: +1.05 / +45.7% relative to May 6, 2029 federal DOE limits while placing #635 of 706 among 706 Hybrid/Electric Heat Pump peers like A. O. Smith FPTU-50 1**.

### Will State HP6-50-DHPT 1** fit through a standard utility door and 72-inch basement ceiling?

Measuring 63 in. tall by 15 in. diameter, State HP6-50-DHPT 1** notes: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (15" d). Reserve space above the jacket for T&P piping and anode removal.

### Do existing utility hookups support State HP6-50-DHPT 1** during replacement?

Electrical specs for State HP6-50-DHPT 1** call for 240V at 22A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.

### What is the estimated 10-year operating spend for State HP6-50-DHPT 1**?

At 18.16 cents/kWh national residential pricing, State HP6-50-DHPT 1**'s 970 kWh/yr draw equals roughly $176 annually or $1,760 across a 10-year horizon (ranging from $142/yr in Washington hydro tiers up to $458/yr in Hawaii).

### When is State HP6-50-DHPT 1** a poor fit for a residential replacement?

Avoid placing State HP6-50-DHPT 1** directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.

### What First Hour Rating or flow capacity does State HP6-50-DHPT 1** deliver?

With 66 gal FHR (-6 gal vs. 72 gal median), State HP6-50-DHPT 1** fits larger 3–5 person homes cleanly.

### How do you verify manufacturing age and recall status on State HP6-50-DHPT 1**?

CPSC SaferProducts records show 4 brand-level recall notices mentioning State as of 2026-11-23, including #19029 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

### Does State HP6-50-DHPT 1** qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for State HP6-50-DHPT 1**. Closest peer in Hybrid/Electric Heat Pump is A. O. Smith FPTU-50 1** (3.35 UEF).

## Which Sizing and Compliance Guides Pair with HP6-50-DHPT 1**?

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare A. O. Smith FPTU-50 1** (3.35 UEF)→](https://gcsradheat.com/water-heaters/a-o-smith/fptu-50-1/)
- [Compare American HPHE6250H045DV 1** (3.35 UEF)→](https://gcsradheat.com/water-heaters/american/hphe6250h045dv-1/)
- [View All State Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/state/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)