title: "State HPAX-40-DHPT 2** (3.6 UEF, 36 gal)"
url: https://gcsradheat.com/water-heaters/state/hpax-40-dhpt-2/
description: "Certified at 3.6 UEF across its 36-gallon nominal tank, 55 gal First Hour Rating, State HPAX-40-DHPT 2** (Hybrid/Electric Heat Pump, Electric) places #401 of."
---

ENERGY STAR water heater model · PD 3417481

# State HPAX-40-DHPT 2** Water Heater Specifications (3.6 UEF)

Certified at 3.6 UEF across its 36-gallon nominal tank, 55 gal First Hour Rating, State HPAX-40-DHPT 2** (Hybrid/Electric Heat Pump, Electric) places #401 of 706 out of 706 ENERGY STAR models (PD 3417481). Its May 6, 2029 10 CFR 430.32 status reads Pass: +1.30 / +56.5%. Rated annual electricity draw of 902 kWh/yr equates to roughly $164/yr ($1,638 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith CAHP-40 2** (3.6 UEF).

- **Uniform Energy Factor**: 3.6 UEF

- **Cohort UEF Rank**: #401 of 706

- **First Hour Rating**: 55 gal

- **Storage Volume**: 36 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.30 / +56.5%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows State HPAX-40-DHPT 2** relative to the cohort median.

Efficiency comparison & rule summary

Tested at 3.6 UEF, State HPAX-40-DHPT 2** places #401 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (-0.10 UEF vs. 3.70 UEF median).

State HPAX-40-DHPT 2** clears 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.30 UEF (+56.5% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 902 kWh/yr for State HPAX-40-DHPT 2** runs ~$164/yr vs. ~$641/yr for a 0.92 UEF electric tank.

State electric sensitivity for State HPAX-40-DHPT 2**: 10-year operating spend spans $1,320 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,256 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Closest alternatives to State HPAX-40-DHPT 2** include A. O. Smith CAHP-40 2** (3.6 UEF, at parity) alongside American HPA10240H045DV 2** (3.6 UEF, at parity).

## Which Specs Set State HPAX-40-DHPT 2** Apart From Cohort Averages?

Ranked #401 of 706 inside the 706-model Hybrid/Electric Heat Pump cohort, State HPAX-40-DHPT 2** is evaluated row by row below against category medians.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [State](https://gcsradheat.com/brands/state/) | 81 certified listings | ENERGY STAR PD 3417481 |
| Model Number | HPAX-40-DHPT 2** | Draw pattern: Medium-Usage | HPAX-40-DHPT 2** |
| Uniform Energy Factor (UEF) | 3.6 | -0.10 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 55 gal | -17 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 902 kWh/yr | -170 kWh/yr vs. 1,072 kWh/yr median | Est. $164/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 426% | -3.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 66" H x 20" D | Verify 72 in. vertical headroom; clears 28 in. utility doorway (20" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 22 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2025-12-12 | Certified 2025-12-12 | Markets: United States |

## How Do Regional kWh Prices Impact HPAX-40-DHPT 2** Over 10 Years?

Using EIA Table 5.6.A benchmarks, State HPAX-40-DHPT 2**'s 902 kWh/yr draw translates to roughly $164/yr on typical US residential bills.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $164/yr | $1,638 | $4,772 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $426/yr | $4,256 | $12,399 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $268/yr | $2,683 | $7,818 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $144/yr | $1,435 | $4,181 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $132/yr | $1,320 | $3,845 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (902 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## What Should State Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC SaferProducts snapshot includes 4 filings tied to State; verify whether your HPAX-40-DHPT 2** production run falls inside affected ranges. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

**4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range**

- **Recall #19029 (2018-11-08):** A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard ([CPSC Notice](https://www.cpsc.gov/Recalls/2019/A-O-Smith-Recalls-Ultra-Low-NOx-Water-Heaters-Due-to-Fire-Hazard))
- **Recall #08241 (2008-04-03):** A.O. Smith Recalls Gas Water Heaters Due to Fire and Carbon Monoxide Hazards ([CPSC Notice](https://www.cpsc.gov/Recalls/2008/AO-Smith-Recalls-Gas-Water-Heaters-Due-to-Fire-and-Carbon-Monoxide-Hazards))
- **Recall #06002 (2005-10-06):** CPSC, A.O. Smith Announce Recall of Water Heaters ([CPSC Notice](https://www.cpsc.gov/Recalls/2006/CPSC-AO-Smith-Recall-of-Water-Heaters))
- **Recall #04128 (2004-04-28):** CPSC, White-Rodgers Announce Recall of LP and Convertible Gas Water Heater Temperature Controls ([CPSC Notice](https://www.cpsc.gov/Recalls/2004/CPSC-White-Rodgers-Announce-Recall-of-LP-and-Convertible-Gas-Water-Heater-Temperature-Controls-))

## How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?

Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [A. O. Smith CAHP-40 2**](https://gcsradheat.com/water-heaters/a-o-smith/cahp-40-2/) | Hybrid/Electric Heat Pump | 36 gal | 55 gal | 3.6 (at parity) | 902 |
| [American HPA10240H045DV 2**](https://gcsradheat.com/water-heaters/american/hpa10240h045dv-2/) | Hybrid/Electric Heat Pump | 36 gal | 55 gal | 3.6 (at parity) | 902 |
| [Lochinvar CHPA-40 2**](https://gcsradheat.com/water-heaters/lochinvar/chpa-40-2/) | Hybrid/Electric Heat Pump | 36 gal | 55 gal | 3.6 (at parity) | 902 |
| [RELIANCE WATER HEATERS 10-40-DHPTA 2**](https://gcsradheat.com/water-heaters/reliance-water-heaters/10-40-dhpta-2/) | Hybrid/Electric Heat Pump | 36 gal | 55 gal | 3.6 (at parity) | 902 |
| [A. O. Smith HPA10-40H45DV 2**](https://gcsradheat.com/water-heaters/a-o-smith/hpa10-40h45dv-2/) | Hybrid/Electric Heat Pump | 36 gal | 55 gal | 3.6 (at parity) | 902 |

## Which Home Setups Are NOT a Fit for State HPAX-40-DHPT 2**?

Comparing State HPAX-40-DHPT 2** against A. O. Smith CAHP-40 2** requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

### Key Limitations & Exclusions

- State HPAX-40-DHPT 2** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting State HPAX-40-DHPT 2** directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing State HPAX-40-DHPT 2 Strong Fit — 3.6 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare A. O. Smith CAHP-40 2** footprint.

## Frequently Asked Technical Questions: State HPAX-40-DHPT 2**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### How does State HPAX-40-DHPT 2** score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; State HPAX-40-DHPT 2** logs 3.6 UEF (Pass: +1.30 / +56.5%) within the 706-unit Hybrid/Electric Heat Pump group.

### What physical clearance dimensions apply when installing State HPAX-40-DHPT 2**?

With a 66 in. height and 20 in. diameter, State HPAX-40-DHPT 2** fits spaces matching: verify 72 in. vertical headroom; clears 28 in. utility doorway (20" d), plus 6–12 in. above for plumbing shutoffs.

### What 240V circuit or IFGC fuel line capacity fits State HPAX-40-DHPT 2**?

Powered via 240V at 22A max, State HPAX-40-DHPT 2** requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.

### How do state electricity prices change annual costs for State HPAX-40-DHPT 2**?

Annual electric spend for State HPAX-40-DHPT 2** (902 kWh/yr) averages $164/yr nationwide (ranging from $132/yr in Washington hydro tiers up to $426/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.

### What homeowner setups should avoid choosing State HPAX-40-DHPT 2**?

Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on State HPAX-40-DHPT 2**.

### Is State HPAX-40-DHPT 2** sized adequately for a 2-to-4-person household?

ENERGY STAR certifies State HPAX-40-DHPT 2** at 55 gal First Hour Rating (-17 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.

### Does State have active CPSC SaferProducts notices affecting HPAX-40-DHPT 2**?

CPSC SaferProducts records show 4 brand-level recall notices mentioning State as of 2026-11-23, including #19029 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

### Which competing water heater matches State HPAX-40-DHPT 2** (3.6 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for State HPAX-40-DHPT 2**. Closest peer in Hybrid/Electric Heat Pump is A. O. Smith CAHP-40 2** (3.6 UEF).

## Essential Pre-Install Guides for State HPAX-40-DHPT 2**

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare A. O. Smith CAHP-40 2** (3.6 UEF)→](https://gcsradheat.com/water-heaters/a-o-smith/cahp-40-2/)
- [Compare American HPA10240H045DV 2** (3.6 UEF)→](https://gcsradheat.com/water-heaters/american/hpa10240h045dv-2/)
- [View All State Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/state/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)