# State HPAX-50-DHPT 2** Water Heater Specifications (3.68 UEF)

Certified at 3.68 UEF across its 46-gallon nominal tank, 65 gal First Hour Rating, State HPAX-50-DHPT 2** (Hybrid/Electric Heat Pump, Electric) places #389 of 706 out of 706 ENERGY STAR models (PD 3417486). Its May 6, 2029 10 CFR 430.32 status reads Pass: +1.38 / +60.0%. Rated annual electricity draw of 883 kWh/yr equates to roughly $160/yr ($1,604 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith CAHP-50 2** (3.68 UEF).

- **Uniform Energy Factor**: 3.68 UEF

- **Cohort UEF Rank**: #389 of 706

- **First Hour Rating**: 65 gal

- **Storage Volume**: 46 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.38 / +60.0%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows State HPAX-50-DHPT 2** relative to the cohort median.

Efficiency comparison & rule summary

Tested at 3.68 UEF, State HPAX-50-DHPT 2** places #389 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (-0.02 UEF vs. 3.70 UEF median).

State HPAX-50-DHPT 2** clears 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.38 UEF (+60.0% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 883 kWh/yr for State HPAX-50-DHPT 2** runs ~$160/yr vs. ~$641/yr for a 0.92 UEF electric tank.

State electric sensitivity for State HPAX-50-DHPT 2**: 10-year operating spend spans $1,292 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,166 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Closest alternatives to State HPAX-50-DHPT 2** include A. O. Smith CAHP-50 2** (3.68 UEF, at parity) alongside American HPA10250H045DV 2** (3.68 UEF, at parity).

## How Complete Are the Certified Metrics for State HPAX-50-DHPT 2**?

Standing at #389 of 706 among 706 certified Hybrid/Electric Heat Pump heaters, State HPAX-50-DHPT 2** brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [State](https://gcsradheat.com/brands/state/) | 81 certified listings | ENERGY STAR PD 3417486 |
| Model Number | HPAX-50-DHPT 2** | Draw pattern: Medium-Usage | HPAX-50-DHPT 2** |
| Uniform Energy Factor (UEF) | 3.68 | -0.02 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 65 gal | -7 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 883 kWh/yr | -189 kWh/yr vs. 1,072 kWh/yr median | Est. $160/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 416% | -13.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 63" H x 15" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (15" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 22 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2025-12-12 | Certified 2025-12-12 | Markets: United States |

## What Is the Projected Utility Bill for HPAX-50-DHPT 2** by State?

At 883 kWh/yr, State HPAX-50-DHPT 2** averages about $160/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $160/yr | $1,604 | $4,811 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $417/yr | $4,166 | $12,498 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $263/yr | $2,627 | $7,881 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $140/yr | $1,405 | $4,215 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $129/yr | $1,292 | $3,875 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (883 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Are State Models Affected by Current CPSC Notices?

Review 4 brand-matched CPSC entries pulled 2026-11-23 for State and confirm your serial tag before scheduling contractor service. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

**4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range**

- **Recall #19029 (2018-11-08):** A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard ([CPSC Notice](https://www.cpsc.gov/Recalls/2019/A-O-Smith-Recalls-Ultra-Low-NOx-Water-Heaters-Due-to-Fire-Hazard))
- **Recall #08241 (2008-04-03):** A.O. Smith Recalls Gas Water Heaters Due to Fire and Carbon Monoxide Hazards ([CPSC Notice](https://www.cpsc.gov/Recalls/2008/AO-Smith-Recalls-Gas-Water-Heaters-Due-to-Fire-and-Carbon-Monoxide-Hazards))
- **Recall #06002 (2005-10-06):** CPSC, A.O. Smith Announce Recall of Water Heaters ([CPSC Notice](https://www.cpsc.gov/Recalls/2006/CPSC-AO-Smith-Recall-of-Water-Heaters))
- **Recall #04128 (2004-04-28):** CPSC, White-Rodgers Announce Recall of LP and Convertible Gas Water Heater Temperature Controls ([CPSC Notice](https://www.cpsc.gov/Recalls/2004/CPSC-White-Rodgers-Announce-Recall-of-LP-and-Convertible-Gas-Water-Heater-Temperature-Controls-))

## Which 5 Models Offer Similar Output to HPAX-50-DHPT 2**?

Ordered by minimal capacity and UEF spread relative to State HPAX-50-DHPT 2**, these five certified peers give direct replacement benchmarks.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [A. O. Smith CAHP-50 2**](https://gcsradheat.com/water-heaters/a-o-smith/cahp-50-2/) | Hybrid/Electric Heat Pump | 46 gal | 65 gal | 3.68 (at parity) | 883 |
| [American HPA10250H045DV 2**](https://gcsradheat.com/water-heaters/american/hpa10250h045dv-2/) | Hybrid/Electric Heat Pump | 46 gal | 65 gal | 3.68 (at parity) | 883 |
| [Lochinvar CHPA-50 2**](https://gcsradheat.com/water-heaters/lochinvar/chpa-50-2/) | Hybrid/Electric Heat Pump | 46 gal | 65 gal | 3.68 (at parity) | 883 |
| [RELIANCE WATER HEATERS 10-50-DHPTA 2**](https://gcsradheat.com/water-heaters/reliance-water-heaters/10-50-dhpta-2/) | Hybrid/Electric Heat Pump | 46 gal | 65 gal | 3.68 (at parity) | 883 |
| [A. O. Smith HPA10-50H45DV 2**](https://gcsradheat.com/water-heaters/a-o-smith/hpa10-50h45dv-2/) | Hybrid/Electric Heat Pump | 46 gal | 65 gal | 3.68 (at parity) | 883 |

## Who Is State HPAX-50-DHPT 2** Best For — and When Should You Pick A. O. Smith CAHP-50 2**?

Evaluate whether State HPAX-50-DHPT 2**'s Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.

### Key Limitations & Exclusions

- State HPAX-50-DHPT 2** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting State HPAX-50-DHPT 2** directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing State HPAX-50-DHPT 2 Strong Fit — 3.68 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare A. O. Smith CAHP-50 2** footprint.

## Practical Specs & Code Questions for State HPAX-50-DHPT 2**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### How does State HPAX-50-DHPT 2** (3.68 UEF) compare to 2029 federal DOE floors?

Evaluated against May 6, 2029 10 CFR 430.32 thresholds, State HPAX-50-DHPT 2** records 3.68 UEF (Pass: +1.38 / +60.0%), placing #389 of 706 out of 706 certified Hybrid/Electric Heat Pump configurations.

### Does State HPAX-50-DHPT 2** fit inside a tight hallway closet or low-headroom utility room?

State HPAX-50-DHPT 2** requires room for its 63 in. vertical shell and 15 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (15" d)), plus service access for annual sediment draining.

### What power supply or fuel line specs govern State HPAX-50-DHPT 2**?

For State HPAX-50-DHPT 2**, plan a 240V circuit at 22A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.

### What annual utility bill should homeowners budget for State HPAX-50-DHPT 2**?

Using 883 kWh/yr, State HPAX-50-DHPT 2** generates an estimated $160/yr electric bill at 18.16 cents/kWh (ranging from $129/yr in Washington hydro tiers up to $417/yr in Hawaii)—use the custom rate slider above for your utility tariff.

### What are the main drawbacks of State HPAX-50-DHPT 2** (3.68 UEF)?

State HPAX-50-DHPT 2** requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or A. O. Smith CAHP-50 2**.

### What hot-water delivery rating governs State HPAX-50-DHPT 2**?

Rated for 65 gal FHR (-7 gal vs. 72 gal median), State HPAX-50-DHPT 2** prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.

### Where do homeowners screen State HPAX-50-DHPT 2** for recalls and tank age?

CPSC SaferProducts records show 4 brand-level recall notices mentioning State as of 2026-11-23, including #19029 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

### What alternative models sit closest to State HPAX-50-DHPT 2** in the Hybrid/Electric Heat Pump class?

Closest peer in Hybrid/Electric Heat Pump is A. O. Smith CAHP-50 2** (3.68 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

## Installation, Serial & DOE 2029 Links for HPAX-50-DHPT 2**

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare A. O. Smith CAHP-50 2** (3.68 UEF)→](https://gcsradheat.com/water-heaters/a-o-smith/cahp-50-2/)
- [Compare American HPA10250H045DV 2** (3.68 UEF)→](https://gcsradheat.com/water-heaters/american/hpa10250h045dv-2/)
- [View All State Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/state/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)