title: "State HPSX-80-DHPT 2** (3.88 UEF, 82 gal)"
url: https://gcsradheat.com/water-heaters/state/hpsx-80-dhpt-2/
description: "Engineered as a Electric Hybrid/Electric Heat Pump unit, State HPSX-80-DHPT 2** achieves a certified 3.88 UEF rating across its 82-gallon nominal tank, 95 gal."
---

ENERGY STAR water heater model · PD 2408842

# State HPSX-80-DHPT 2** Water Heater Specifications (3.88 UEF)

Engineered as a Electric Hybrid/Electric Heat Pump unit, State HPSX-80-DHPT 2** achieves a certified 3.88 UEF rating across its 82-gallon nominal tank, 95 gal First Hour Rating and ranks #165 of 706 in its 706-model cohort (PD 2408842), recording Pass: +1.38 / +55.2% under 2029 DOE rules. Rated annual electricity draw of 1,279 kWh/yr equates to roughly $232/yr ($2,323 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPS10-80H45DV 2** (3.88 UEF).

- **Uniform Energy Factor**: 3.88 UEF

- **Cohort UEF Rank**: #165 of 706 (top 30.6%)

- **First Hour Rating**: 95 gal

- **Storage Volume**: 82 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.38 / +55.2%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows State HPSX-80-DHPT 2** relative to the cohort median.

Efficiency comparison & rule summary

Within the 706-unit Hybrid/Electric Heat Pump cohort, State HPSX-80-DHPT 2** logs 3.88 UEF and ranks #165 of 706.

Against 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF), State HPSX-80-DHPT 2** holds a +1.38 UEF (+55.2%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 1,279 kWh/yr for State HPSX-80-DHPT 2** runs ~$232/yr vs. ~$980/yr for a 0.92 UEF electric tank.

State electric sensitivity for State HPSX-80-DHPT 2**: 10-year operating spend spans $1,871 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,034 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Cross-shopping State HPSX-80-DHPT 2** (3.88 UEF)? Check A. O. Smith HPS10-80H45DV 2** (3.88 UEF, at parity) and American HPS10280H045DV 2** (3.88 UEF, at parity).

## How Complete Are the Certified Metrics for State HPSX-80-DHPT 2**?

Standing at #165 of 706 (top 30.6%) among 706 certified Hybrid/Electric Heat Pump heaters, State HPSX-80-DHPT 2** brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [State](https://gcsradheat.com/brands/state/) | 81 certified listings | ENERGY STAR PD 2408842 |
| Model Number | HPSX-80-DHPT 2** | Draw pattern: High-Usage | HPSX-80-DHPT 2** |
| Uniform Energy Factor (UEF) | 3.88 | +0.18 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 95 gal | +23 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,279 kWh/yr | +207 kWh/yr vs. 1,072 kWh/yr median | Est. $232/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 430% | +1.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 69" H x 27" D | Verify 72 in. vertical headroom; tight at 28 in. door (27" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 22 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2025-12-12 | Certified 2025-12-12 | Markets: United States |

## What Is the Projected Utility Bill for HPSX-80-DHPT 2** by State?

At 1,279 kWh/yr, State HPSX-80-DHPT 2** averages about $232/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $232/yr | $2,323 | $7,473 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $603/yr | $6,034 | $19,415 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $381/yr | $3,805 | $12,242 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $203/yr | $2,035 | $6,547 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $187/yr | $1,871 | $6,020 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (1,279 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Are State Models Affected by Current CPSC Notices?

Review 4 brand-matched CPSC entries pulled 2026-11-23 for State and confirm your serial tag before scheduling contractor service. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

**4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range**

- **Recall #19029 (2018-11-08):** A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard ([CPSC Notice](https://www.cpsc.gov/Recalls/2019/A-O-Smith-Recalls-Ultra-Low-NOx-Water-Heaters-Due-to-Fire-Hazard))
- **Recall #08241 (2008-04-03):** A.O. Smith Recalls Gas Water Heaters Due to Fire and Carbon Monoxide Hazards ([CPSC Notice](https://www.cpsc.gov/Recalls/2008/AO-Smith-Recalls-Gas-Water-Heaters-Due-to-Fire-and-Carbon-Monoxide-Hazards))
- **Recall #06002 (2005-10-06):** CPSC, A.O. Smith Announce Recall of Water Heaters ([CPSC Notice](https://www.cpsc.gov/Recalls/2006/CPSC-AO-Smith-Recall-of-Water-Heaters))
- **Recall #04128 (2004-04-28):** CPSC, White-Rodgers Announce Recall of LP and Convertible Gas Water Heater Temperature Controls ([CPSC Notice](https://www.cpsc.gov/Recalls/2004/CPSC-White-Rodgers-Announce-Recall-of-LP-and-Convertible-Gas-Water-Heater-Temperature-Controls-))

## Which 5 Models Offer Similar Output to HPSX-80-DHPT 2**?

Ordered by minimal capacity and UEF spread relative to State HPSX-80-DHPT 2**, these five certified peers give direct replacement benchmarks.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [A. O. Smith HPS10-80H45DV 2**](https://gcsradheat.com/water-heaters/a-o-smith/hps10-80h45dv-2/) | Hybrid/Electric Heat Pump | 82 gal | 95 gal | 3.88 (at parity) | 1,279 |
| [American HPS10280H045DV 2**](https://gcsradheat.com/water-heaters/american/hps10280h045dv-2/) | Hybrid/Electric Heat Pump | 82 gal | 95 gal | 3.88 (at parity) | 1,279 |
| [Lochinvar HPSA080KD 2**](https://gcsradheat.com/water-heaters/lochinvar/hpsa080kd-2/) | Hybrid/Electric Heat Pump | 82 gal | 95 gal | 3.88 (at parity) | 1,279 |
| [RELIANCE WATER HEATERS 10-80-DHPTS 2**](https://gcsradheat.com/water-heaters/reliance-water-heaters/10-80-dhpts-2/) | Hybrid/Electric Heat Pump | 82 gal | 95 gal | 3.88 (at parity) | 1,279 |
| [A. O. Smith HPSN10-80H45DV 2**](https://gcsradheat.com/water-heaters/a-o-smith/hpsn10-80h45dv-2/) | Hybrid/Electric Heat Pump | 82 gal | 95 gal | 3.88 (at parity) | 1,279 |

## Who Is State HPSX-80-DHPT 2** Best For — and When Should You Pick A. O. Smith HPS10-80H45DV 2**?

Evaluate whether State HPSX-80-DHPT 2**'s Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.

### Key Limitations & Exclusions

- State HPSX-80-DHPT 2** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting State HPSX-80-DHPT 2** directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing State HPSX-80-DHPT 2 Strong Fit — 3.88 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare A. O. Smith HPS10-80H45DV 2** footprint.

## Practical Specs & Code Questions for State HPSX-80-DHPT 2**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### How does State HPSX-80-DHPT 2** (3.88 UEF) compare to 2029 federal DOE floors?

Evaluated against May 6, 2029 10 CFR 430.32 thresholds, State HPSX-80-DHPT 2** records 3.88 UEF (Pass: +1.38 / +55.2%), placing #165 of 706 (top 30.6%) out of 706 certified Hybrid/Electric Heat Pump configurations.

### Does State HPSX-80-DHPT 2** fit inside a tight hallway closet or low-headroom utility room?

State HPSX-80-DHPT 2** requires room for its 69 in. vertical shell and 27 in. diameter (verify 72 in. vertical headroom; tight at 28 in. door (27" d)), plus service access for annual sediment draining.

### What power supply or fuel line specs govern State HPSX-80-DHPT 2**?

For State HPSX-80-DHPT 2**, plan a 240V circuit at 22A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.

### What annual utility bill should homeowners budget for State HPSX-80-DHPT 2**?

Using 1,279 kWh/yr, State HPSX-80-DHPT 2** generates an estimated $232/yr electric bill at 18.16 cents/kWh (ranging from $187/yr in Washington hydro tiers up to $603/yr in Hawaii)—use the custom rate slider above for your utility tariff.

### What are the main drawbacks of State HPSX-80-DHPT 2** (3.88 UEF)?

State HPSX-80-DHPT 2** requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or A. O. Smith HPS10-80H45DV 2**.

### What hot-water delivery rating governs State HPSX-80-DHPT 2**?

Rated for 95 gal FHR (+23 gal vs. 72 gal median), State HPSX-80-DHPT 2** prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.

### Where do homeowners screen State HPSX-80-DHPT 2** for recalls and tank age?

CPSC SaferProducts records show 4 brand-level recall notices mentioning State as of 2026-11-23, including #19029 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

### What alternative models sit closest to State HPSX-80-DHPT 2** in the Hybrid/Electric Heat Pump class?

Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPS10-80H45DV 2** (3.88 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

## Installation, Serial & DOE 2029 Links for HPSX-80-DHPT 2**

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare A. O. Smith HPS10-80H45DV 2** (3.88 UEF)→](https://gcsradheat.com/water-heaters/a-o-smith/hps10-80h45dv-2/)
- [Compare American HPS10280H045DV 2** (3.88 UEF)→](https://gcsradheat.com/water-heaters/american/hps10280h045dv-2/)
- [View All State Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/state/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)