title: "State HPX-50-DHPTCTA 1** (3.45 UEF, 46 gal)"
url: https://gcsradheat.com/water-heaters/state/hpx-50-dhptcta-1/
description: "With PD 2408888 certification, State HPX-50-DHPTCTA 1** (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.45 UEF rating across its 46-gallon nominal."
---

ENERGY STAR water heater model · PD 2408888

# State HPX-50-DHPTCTA 1** Water Heater Specifications (3.45 UEF)

With PD 2408888 certification, State HPX-50-DHPTCTA 1** (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.45 UEF rating across its 46-gallon nominal tank, 66 gal First Hour Rating, standing #563 of 706 across 706 peers with Pass: +1.15 / +50.0% for May 6, 2029. Rated annual electricity draw of 902 kWh/yr equates to roughly $164/yr ($1,638 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HP1050H45DV 1** (3.45 UEF).

- **Uniform Energy Factor**: 3.45 UEF

- **Cohort UEF Rank**: #563 of 706

- **First Hour Rating**: 66 gal

- **Storage Volume**: 46 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.15 / +50.0%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows State HPX-50-DHPTCTA 1** relative to the cohort median.

Efficiency comparison & rule summary

ENERGY STAR certification places State HPX-50-DHPTCTA 1** at 3.45 UEF (#563 of 706; -0.25 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.

May 6, 2029 readiness: State HPX-50-DHPTCTA 1** stands +1.15 UEF (+50.0%) relative to 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 902 kWh/yr for State HPX-50-DHPTCTA 1** runs ~$164/yr vs. ~$614/yr for a 0.92 UEF electric tank.

State electric sensitivity for State HPX-50-DHPTCTA 1**: 10-year operating spend spans $1,320 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,256 in Hawaii (Highest EIA State) (47.18 cents/kWh).

In the Hybrid/Electric Heat Pump tier, A. O. Smith HP1050H45DV 1** (3.45 UEF, at parity) and American HPHE10250H045DVCTA-1** (3.45 UEF, at parity) bracket State HPX-50-DHPTCTA 1**.

## Which Specs Set State HPX-50-DHPTCTA 1** Apart From Cohort Averages?

Ranked #563 of 706 inside the 706-model Hybrid/Electric Heat Pump cohort, State HPX-50-DHPTCTA 1** is evaluated row by row below against category medians.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [State](https://gcsradheat.com/brands/state/) | 81 certified listings | ENERGY STAR PD 2408888 |
| Model Number | HPX-50-DHPTCTA 1** | Draw pattern: Medium-Usage | HPX-50-DHPTCTA 1** |
| Uniform Energy Factor (UEF) | 3.45 | -0.25 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 66 gal | -6 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 902 kWh/yr | -170 kWh/yr vs. 1,072 kWh/yr median | Est. $164/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 407% | -22.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 63" H x 15" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (15" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 22 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2023-02-23 | Certified 2023-02-23 | Markets: United States, Canada |

## How Do Regional kWh Prices Impact HPX-50-DHPTCTA 1** Over 10 Years?

Using EIA Table 5.6.A benchmarks, State HPX-50-DHPTCTA 1**'s 902 kWh/yr draw translates to roughly $164/yr on typical US residential bills.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $164/yr | $1,638 | $4,504 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $426/yr | $4,256 | $11,701 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $268/yr | $2,683 | $7,378 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $144/yr | $1,435 | $3,946 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $132/yr | $1,320 | $3,628 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (902 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## What Should State Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC SaferProducts snapshot includes 4 filings tied to State; verify whether your HPX-50-DHPTCTA 1** production run falls inside affected ranges. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

**4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range**

- **Recall #19029 (2018-11-08):** A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard ([CPSC Notice](https://www.cpsc.gov/Recalls/2019/A-O-Smith-Recalls-Ultra-Low-NOx-Water-Heaters-Due-to-Fire-Hazard))
- **Recall #08241 (2008-04-03):** A.O. Smith Recalls Gas Water Heaters Due to Fire and Carbon Monoxide Hazards ([CPSC Notice](https://www.cpsc.gov/Recalls/2008/AO-Smith-Recalls-Gas-Water-Heaters-Due-to-Fire-and-Carbon-Monoxide-Hazards))
- **Recall #06002 (2005-10-06):** CPSC, A.O. Smith Announce Recall of Water Heaters ([CPSC Notice](https://www.cpsc.gov/Recalls/2006/CPSC-AO-Smith-Recall-of-Water-Heaters))
- **Recall #04128 (2004-04-28):** CPSC, White-Rodgers Announce Recall of LP and Convertible Gas Water Heater Temperature Controls ([CPSC Notice](https://www.cpsc.gov/Recalls/2004/CPSC-White-Rodgers-Announce-Recall-of-LP-and-Convertible-Gas-Water-Heater-Temperature-Controls-))

## How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?

Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [A. O. Smith HP1050H45DV 1**](https://gcsradheat.com/water-heaters/a-o-smith/hp1050h45dv-1/) | Hybrid/Electric Heat Pump | 46 gal | 66 gal | 3.45 (at parity) | 902 |
| [American HPHE10250H045DVCTA-1**](https://gcsradheat.com/water-heaters/american/hphe10250h045dvcta-1/) | Hybrid/Electric Heat Pump | 46 gal | 66 gal | 3.45 (at parity) | 902 |
| [Lochinvar HPA052KD 1**](https://gcsradheat.com/water-heaters/lochinvar/hpa052kd-1/) | Hybrid/Electric Heat Pump | 46 gal | 66 gal | 3.45 (at parity) | 902 |
| [RELIANCE WATER HEATERS 10-50-DHPHTCTA 1**](https://gcsradheat.com/water-heaters/reliance-water-heaters/10-50-dhphtcta-1/) | Hybrid/Electric Heat Pump | 46 gal | 66 gal | 3.45 (at parity) | 902 |
| [A. O. Smith HP1050H45DVCTA-1**](https://gcsradheat.com/water-heaters/a-o-smith/hp1050h45dvcta-1/) | Hybrid/Electric Heat Pump | 46 gal | 66 gal | 3.45 (at parity) | 902 |

## What Are the Limitations of State HPX-50-DHPTCTA 1** and Who Should Not Install It?

Before ordering State HPX-50-DHPTCTA 1** (Hybrid/Electric Heat Pump, 3.45 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.

### Key Limitations & Exclusions

- State HPX-50-DHPTCTA 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting State HPX-50-DHPTCTA 1** directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing State HPX-50-DHPTCTA 1 Strong Fit — 3.45 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare A. O. Smith HP1050H45DV 1** footprint.

## Frequently Asked Technical Questions: State HPX-50-DHPTCTA 1**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Does State HPX-50-DHPTCTA 1** pass the May 6, 2029 federal DOE efficiency rule?

State HPX-50-DHPTCTA 1** carries a verified 3.45 UEF rating (Pass: +1.15 / +50.0%), ranking #563 of 706 across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.

### What doorway width and ceiling height does State HPX-50-DHPTCTA 1** need?

State HPX-50-DHPTCTA 1** stands 63 in. high with a 15 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (15" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.

### What gas pipe size or electrical breaker does State HPX-50-DHPTCTA 1** require?

State HPX-50-DHPTCTA 1** uses a 240V branch circuit at 22A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.

### How much electricity or energy does State HPX-50-DHPTCTA 1** cost per year to run?

Rated at 902 kWh/yr, State HPX-50-DHPTCTA 1** costs about $164/yr ($1,640 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $132/yr in Washington hydro tiers up to $426/yr in Hawaii).

### Who should NOT install State HPX-50-DHPTCTA 1**, and what are its limits?

State HPX-50-DHPTCTA 1** (3.45 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.

### How many bathrooms or people can State HPX-50-DHPTCTA 1** serve at peak demand?

State HPX-50-DHPTCTA 1** achieves a 66 gal First Hour Rating (-6 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.

### Are there CPSC safety recalls or serial checks for State HPX-50-DHPTCTA 1**?

CPSC SaferProducts records show 4 brand-level recall notices mentioning State as of 2026-11-23, including #19029 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

### What 2026 rebates apply to State HPX-50-DHPTCTA 1**, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HP1050H45DV 1** (3.45 UEF).

## Essential Pre-Install Guides for State HPX-50-DHPTCTA 1**

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare A. O. Smith HP1050H45DV 1** (3.45 UEF)→](https://gcsradheat.com/water-heaters/a-o-smith/hp1050h45dv-1/)
- [Compare American HPHE10250H045DVCTA-1** (3.45 UEF)→](https://gcsradheat.com/water-heaters/american/hphe10250h045dvcta-1/)
- [View All State Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/state/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)