# U.S. Craftmaster HPHE2F80HD045VU 1** Water Heater Specifications (3.45 UEF)

Engineered as a Electric Hybrid/Electric Heat Pump unit, U.S. Craftmaster HPHE2F80HD045VU 1** achieves a certified 3.45 UEF rating across its 82-gallon nominal tank, 84 gal First Hour Rating and ranks #563 of 706 in its 706-model cohort (PD 2408877), recording Pass: +0.95 / +38.0% under 2029 DOE rules. Rated annual electricity draw of 1,396 kWh/yr equates to roughly $254/yr ($2,535 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith FPTU-80 1** (3.45 UEF).

- **Uniform Energy Factor**: 3.45 UEF

- **Cohort UEF Rank**: #563 of 706

- **First Hour Rating**: 84 gal

- **Storage Volume**: 82 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +0.95 / +38.0%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows U.S. Craftmaster HPHE2F80HD045VU 1** relative to the cohort median.

Efficiency comparison & rule summary

Within the 706-unit Hybrid/Electric Heat Pump cohort, U.S. Craftmaster HPHE2F80HD045VU 1** logs 3.45 UEF and ranks #563 of 706.

Against 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF), U.S. Craftmaster HPHE2F80HD045VU 1** holds a +0.95 UEF (+38.0%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 1,396 kWh/yr for U.S. Craftmaster HPHE2F80HD045VU 1** runs ~$254/yr vs. ~$951/yr for a 0.92 UEF electric tank.

State electric sensitivity for U.S. Craftmaster HPHE2F80HD045VU 1**: 10-year operating spend spans $2,042 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,586 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Cross-shopping U.S. Craftmaster HPHE2F80HD045VU 1** (3.45 UEF)? Check A. O. Smith FPTU-80 1** (3.45 UEF, at parity) and American HPHE6280H045DV 1** (3.45 UEF, at parity).

## Where Does U.S. Craftmaster HPHE2F80HD045VU 1** Rank Against Peer Hybrid/Electric Heat Pump Units?

Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, U.S. Craftmaster HPHE2F80HD045VU 1** holds #563 of 706; inspect footprint, circuit load, and efficiency deltas here.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [U.S. Craftmaster](https://gcsradheat.com/brands/u-s-craftmaster/) | 6 certified listings | ENERGY STAR PD 2408877 |
| Model Number | HPHE2F80HD045VU 1** | Draw pattern: High-Usage | HPHE2F80HD045VU 1** |
| Uniform Energy Factor (UEF) | 3.45 | -0.25 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 84 gal | +12 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,396 kWh/yr | +324 kWh/yr vs. 1,072 kWh/yr median | Est. $254/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 233% | -196.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 69" H x 27" D | Verify 72 in. vertical headroom; tight at 28 in. door (27" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 22 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2023-02-23 | Certified 2023-02-23 | Markets: United States |

## How Much Electricity Does HPHE2F80HD045VU 1** Use in Different States?

Estimated at $254/yr nationally (1,396 kWh/yr), 10-year utility spending for U.S. Craftmaster HPHE2F80HD045VU 1** shifts sharply between low-rate hydro and coastal grids.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $254/yr | $2,535 | $6,972 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $659/yr | $6,586 | $18,112 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $415/yr | $4,153 | $11,421 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $222/yr | $2,221 | $6,108 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $204/yr | $2,042 | $5,616 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (1,396 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Does CPSC Flag Any Safety Notices on U.S. Craftmaster Units?

No open CPSC recall alerts appeared for U.S. Craftmaster as of 2026-11-23; you can still decode exact manufacture month and warranty window below. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## Which Competing Hybrid/Electric Heat Pump Models Compare Closest to HPHE2F80HD045VU 1**?

Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to U.S. Craftmaster HPHE2F80HD045VU 1**'s gallon capacity and 3.45 UEF efficiency.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [A. O. Smith FPTU-80 1**](https://gcsradheat.com/water-heaters/a-o-smith/fptu-80-1/) | Hybrid/Electric Heat Pump | 82 gal | 84 gal | 3.45 (at parity) | 1,396 |
| [American HPHE6280H045DV 1**](https://gcsradheat.com/water-heaters/american/hphe6280h045dv-1/) | Hybrid/Electric Heat Pump | 82 gal | 84 gal | 3.45 (at parity) | 1,396 |
| [RELIANCE WATER HEATERS 6-80-DHPHT 1**](https://gcsradheat.com/water-heaters/reliance-water-heaters/6-80-dhpht-1/) | Hybrid/Electric Heat Pump | 82 gal | 84 gal | 3.45 (at parity) | 1,396 |
| [State HP6-80-DHPT 1**](https://gcsradheat.com/water-heaters/state/hp6-80-dhpt-1/) | Hybrid/Electric Heat Pump | 82 gal | 84 gal | 3.45 (at parity) | 1,396 |
| [A. O. Smith HP1080H45DV 1**](https://gcsradheat.com/water-heaters/a-o-smith/hp1080h45dv-1/) | Hybrid/Electric Heat Pump | 82 gal | 86 gal | 3.45 (at parity) | 1,387 |

## Who Is U.S. Craftmaster HPHE2F80HD045VU 1** Best For — and When Should You Pick A. O. Smith FPTU-80 1**?

Evaluate whether U.S. Craftmaster HPHE2F80HD045VU 1**'s Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.

### Key Limitations & Exclusions

- U.S. Craftmaster HPHE2F80HD045VU 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting U.S. Craftmaster HPHE2F80HD045VU 1** directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing U.S. Craftmaster HPHE2F80HD045VU 1 Strong Fit — 3.45 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare A. O. Smith FPTU-80 1** footprint.

## Common Homeowner Questions for U.S. Craftmaster HPHE2F80HD045VU 1**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### How does U.S. Craftmaster HPHE2F80HD045VU 1** (3.45 UEF) compare to 2029 federal DOE floors?

Evaluated against May 6, 2029 10 CFR 430.32 thresholds, U.S. Craftmaster HPHE2F80HD045VU 1** records 3.45 UEF (Pass: +0.95 / +38.0%), placing #563 of 706 out of 706 certified Hybrid/Electric Heat Pump configurations.

### Does U.S. Craftmaster HPHE2F80HD045VU 1** fit inside a tight hallway closet or low-headroom utility room?

U.S. Craftmaster HPHE2F80HD045VU 1** requires room for its 69 in. vertical shell and 27 in. diameter (verify 72 in. vertical headroom; tight at 28 in. door (27" d)), plus service access for annual sediment draining.

### What power supply or fuel line specs govern U.S. Craftmaster HPHE2F80HD045VU 1**?

For U.S. Craftmaster HPHE2F80HD045VU 1**, plan a 240V circuit at 22A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.

### What annual utility bill should homeowners budget for U.S. Craftmaster HPHE2F80HD045VU 1**?

Using 1,396 kWh/yr, U.S. Craftmaster HPHE2F80HD045VU 1** generates an estimated $254/yr electric bill at 18.16 cents/kWh (ranging from $204/yr in Washington hydro tiers up to $659/yr in Hawaii)—use the custom rate slider above for your utility tariff.

### What are the main drawbacks of U.S. Craftmaster HPHE2F80HD045VU 1** (3.45 UEF)?

U.S. Craftmaster HPHE2F80HD045VU 1** requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or A. O. Smith FPTU-80 1**.

### What hot-water delivery rating governs U.S. Craftmaster HPHE2F80HD045VU 1**?

Rated for 84 gal FHR (+12 gal vs. 72 gal median), U.S. Craftmaster HPHE2F80HD045VU 1** prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.

### Where do homeowners screen U.S. Craftmaster HPHE2F80HD045VU 1** for recalls and tank age?

Verified clean against 2026-11-23 CPSC recall feeds for U.S. Craftmaster; use our browser-only serial decoder to inspect U.S. Craftmaster HPHE2F80HD045VU 1**'s age and warranty window.

### What alternative models sit closest to U.S. Craftmaster HPHE2F80HD045VU 1** in the Hybrid/Electric Heat Pump class?

Closest peer in Hybrid/Electric Heat Pump is A. O. Smith FPTU-80 1** (3.45 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

## Next Engineering Checks for U.S. Craftmaster Owners

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare A. O. Smith FPTU-80 1** (3.45 UEF)→](https://gcsradheat.com/water-heaters/a-o-smith/fptu-80-1/)
- [Compare American HPHE6280H045DV 1** (3.45 UEF)→](https://gcsradheat.com/water-heaters/american/hphe6280h045dv-1/)
- [View All U.S. Craftmaster Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/u-s-craftmaster/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)