title: "VAUGHN THERMAL ME120HPT-CN (3.38 UEF, 109 gal)"
url: https://gcsradheat.com/water-heaters/vaughn-thermal/me120hpt-cn/
description: "With PD 3478043 certification, VAUGHN THERMAL ME120HPT-CN (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.38 UEF rating across its 109-gallon."
---

ENERGY STAR water heater model · PD 3478043

# VAUGHN THERMAL ME120HPT-CN Water Heater Specifications (3.38 UEF)

With PD 3478043 certification, VAUGHN THERMAL ME120HPT-CN (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.38 UEF rating across its 109-gallon nominal tank, 105 gal First Hour Rating, standing #631 of 706 across 706 peers with Pass: +0.88 / +35.2% for May 6, 2029. Rated annual electricity draw of 1,467 kWh/yr equates to roughly $266/yr ($2,664 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Hubbell ME120HPT (3.38 UEF).

- **Uniform Energy Factor**: 3.38 UEF

- **Cohort UEF Rank**: #631 of 706

- **First Hour Rating**: 105 gal

- **Storage Volume**: 109 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +0.88 / +35.2%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows VAUGHN THERMAL ME120HPT-CN relative to the cohort median.

Efficiency comparison & rule summary

ENERGY STAR certification places VAUGHN THERMAL ME120HPT-CN at 3.38 UEF (#631 of 706; -0.32 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.

May 6, 2029 readiness: VAUGHN THERMAL ME120HPT-CN stands +0.88 UEF (+35.2%) relative to 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,467 kWh/yr for VAUGHN THERMAL ME120HPT-CN runs ~$266/yr vs. ~$979/yr for a 0.92 UEF electric tank.

State electric sensitivity for VAUGHN THERMAL ME120HPT-CN: 10-year operating spend spans $2,146 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,921 in Hawaii (Highest EIA State) (47.18 cents/kWh).

In the Hybrid/Electric Heat Pump tier, Hubbell ME120HPT (3.38 UEF, at parity) and Noritz NHP120 (3.38 UEF, at parity) bracket VAUGHN THERMAL ME120HPT-CN.

## Where Does VAUGHN THERMAL ME120HPT-CN Rank Against Peer Hybrid/Electric Heat Pump Units?

Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, VAUGHN THERMAL ME120HPT-CN holds #631 of 706; inspect footprint, circuit load, and efficiency deltas here.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [VAUGHN THERMAL](https://gcsradheat.com/brands/vaughn-thermal/) | 13 certified listings | ENERGY STAR PD 3478043 |
| Model Number | ME120HPT-CN | Draw pattern: High-Usage | ME120HPT-CN |
| Uniform Energy Factor (UEF) | 3.38 | -0.32 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 105 gal | +33 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,467 kWh/yr | +395 kWh/yr vs. 1,072 kWh/yr median | Est. $266/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 355% | -74.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 84.5" H x 30" D | Needs >72 in. overhead clearance; tight at 28 in. door (30" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 23 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Sound Pressure Level | 54 dBA | +5 dBA vs. 49 dBA median | Indoor placement check |
| Certification Date | 2024-08-13 | Certified 2024-08-13 | Markets: United States, Canada |

## How Much Electricity Does ME120HPT-CN Use in Different States?

Estimated at $266/yr nationally (1,467 kWh/yr), 10-year utility spending for VAUGHN THERMAL ME120HPT-CN shifts sharply between low-rate hydro and coastal grids.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $266/yr | $2,664 | $7,124 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $692/yr | $6,921 | $18,509 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $436/yr | $4,364 | $11,671 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $233/yr | $2,334 | $6,241 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $215/yr | $2,146 | $5,739 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (1,467 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Does CPSC Flag Any Safety Notices on VAUGHN THERMAL Units?

No open CPSC recall alerts appeared for VAUGHN THERMAL as of 2026-11-23; you can still decode exact manufacture month and warranty window below. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## Which Competing Hybrid/Electric Heat Pump Models Compare Closest to ME120HPT-CN?

Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to VAUGHN THERMAL ME120HPT-CN's gallon capacity and 3.38 UEF efficiency.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Hubbell ME120HPT](https://gcsradheat.com/water-heaters/hubbell/me120hpt/) | Hybrid/Electric Heat Pump | 109 gal | 105 gal | 3.38 (at parity) | 1,467 |
| [Noritz NHP120](https://gcsradheat.com/water-heaters/noritz/nhp120/) | Hybrid/Electric Heat Pump | 109 gal | 105 gal | 3.38 (at parity) | 1,467 |
| [SANCO2 GS5-45HPC-D HP + ECO-119GLBK](https://gcsradheat.com/water-heaters/sanco2/gs5-45hpc-d-hp-eco-119glbk/) | Hybrid/Electric Heat Pump | 119 gal | 134 gal | 3.72 (+0.34) | 1,333 |
| [Reclaim Energy MP120F-RC](https://gcsradheat.com/water-heaters/reclaim-energy/mp120f-rc/) | Hybrid/Electric Heat Pump | 119 gal | 121 gal | 3.75 (+0.37) | 1,296 |
| [SANCO2 GS5-45HPC HP + ECO-119GLBK](https://gcsradheat.com/water-heaters/sanco2/gs5-45hpc-hp-eco-119glbk/) | Hybrid/Electric Heat Pump | 119 gal | 134 gal | 3.72 (+0.34) | 1,333 |

## Who Is VAUGHN THERMAL ME120HPT-CN Best For — and When Should You Pick Hubbell ME120HPT?

Evaluate whether VAUGHN THERMAL ME120HPT-CN's Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.

### Key Limitations & Exclusions

- VAUGHN THERMAL ME120HPT-CN needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 54 dBA; avoid mounting VAUGHN THERMAL ME120HPT-CN directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing VAUGHN THERMAL ME120HPT-CN** Strong Fit — 3.38 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare Hubbell ME120HPT footprint.

## Common Homeowner Questions for VAUGHN THERMAL ME120HPT-CN

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### How does VAUGHN THERMAL ME120HPT-CN (3.38 UEF) compare to 2029 federal DOE floors?

Evaluated against May 6, 2029 10 CFR 430.32 thresholds, VAUGHN THERMAL ME120HPT-CN records 3.38 UEF (Pass: +0.88 / +35.2%), placing #631 of 706 out of 706 certified Hybrid/Electric Heat Pump configurations.

### Does VAUGHN THERMAL ME120HPT-CN fit inside a tight hallway closet or low-headroom utility room?

VAUGHN THERMAL ME120HPT-CN requires room for its 84.5 in. vertical shell and 30 in. diameter (needs >72 in. overhead clearance; tight at 28 in. door (30" d)), plus service access for annual sediment draining.

### What power supply or fuel line specs govern VAUGHN THERMAL ME120HPT-CN?

For VAUGHN THERMAL ME120HPT-CN, plan a 240V circuit at 23A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.

### What annual utility bill should homeowners budget for VAUGHN THERMAL ME120HPT-CN?

Using 1,467 kWh/yr, VAUGHN THERMAL ME120HPT-CN generates an estimated $266/yr electric bill at 18.16 cents/kWh (ranging from $215/yr in Washington hydro tiers up to $692/yr in Hawaii)—use the custom rate slider above for your utility tariff.

### What are the main drawbacks of VAUGHN THERMAL ME120HPT-CN (3.38 UEF)?

VAUGHN THERMAL ME120HPT-CN requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or Hubbell ME120HPT.

### What hot-water delivery rating governs VAUGHN THERMAL ME120HPT-CN?

Rated for 105 gal FHR (+33 gal vs. 72 gal median), VAUGHN THERMAL ME120HPT-CN prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.

### Where do homeowners screen VAUGHN THERMAL ME120HPT-CN for recalls and tank age?

Verified clean against 2026-11-23 CPSC recall feeds for VAUGHN THERMAL; use our browser-only serial decoder to inspect VAUGHN THERMAL ME120HPT-CN's age and warranty window.

### What alternative models sit closest to VAUGHN THERMAL ME120HPT-CN in the Hybrid/Electric Heat Pump class?

Closest peer in Hybrid/Electric Heat Pump is Hubbell ME120HPT (3.38 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

## Next Engineering Checks for VAUGHN THERMAL Owners

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Hubbell ME120HPT (3.38 UEF)→](https://gcsradheat.com/water-heaters/hubbell/me120hpt/)
- [Compare Noritz NHP120 (3.38 UEF)→](https://gcsradheat.com/water-heaters/noritz/nhp120/)
- [View All VAUGHN THERMAL Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/vaughn-thermal/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)