title: "VAUGHN THERMAL ME50HPT-CN (3.46 UEF, 47 gal)"
url: https://gcsradheat.com/water-heaters/vaughn-thermal/me50hpt-cn/
description: "In the 706-unit Hybrid/Electric Heat Pump class, VAUGHN THERMAL ME50HPT-CN (Electric) achieves a certified 3.46 UEF rating across its 47-gallon nominal tank."
---

ENERGY STAR water heater model · PD 3478044

# VAUGHN THERMAL ME50HPT-CN Water Heater Specifications (3.46 UEF)

In the 706-unit Hybrid/Electric Heat Pump class, VAUGHN THERMAL ME50HPT-CN (Electric) achieves a certified 3.46 UEF rating across its 47-gallon nominal tank, 58 gal First Hour Rating (rank #549 of 706, PD 3478044) and verifies as Pass: +1.16 / +50.4% for 2029 DOE floors. Rated annual electricity draw of 938 kWh/yr equates to roughly $170/yr ($1,703 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Hubbell ME50HPT (3.46 UEF).

- **Uniform Energy Factor**: 3.46 UEF

- **Cohort UEF Rank**: #549 of 706

- **First Hour Rating**: 58 gal

- **Storage Volume**: 47 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.16 / +50.4%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows VAUGHN THERMAL ME50HPT-CN relative to the cohort median.

Efficiency comparison & rule summary

VAUGHN THERMAL ME50HPT-CN records 3.46 UEF efficiency, putting it #549 of 706 among 706 Hybrid/Electric Heat Pump peers.

10 CFR 430.32(d)(2) compliance: VAUGHN THERMAL ME50HPT-CN exceeds 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.16 UEF (+50.4%). At EIA August 2026 national rates (18.16 cents/kWh), 938 kWh/yr for VAUGHN THERMAL ME50HPT-CN runs ~$170/yr vs. ~$641/yr for a 0.92 UEF electric tank.

State electric sensitivity for VAUGHN THERMAL ME50HPT-CN: 10-year operating spend spans $1,372 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,425 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Competing options beside VAUGHN THERMAL ME50HPT-CN (3.46 UEF) are Hubbell ME50HPT (3.46 UEF, at parity) and Noritz NHP50 (3.46 UEF, at parity).

## Which Specs Set VAUGHN THERMAL ME50HPT-CN Apart From Cohort Averages?

Ranked #549 of 706 inside the 706-model Hybrid/Electric Heat Pump cohort, VAUGHN THERMAL ME50HPT-CN is evaluated row by row below against category medians.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [VAUGHN THERMAL](https://gcsradheat.com/brands/vaughn-thermal/) | 13 certified listings | ENERGY STAR PD 3478044 |
| Model Number | ME50HPT-CN | Draw pattern: Medium-Usage | ME50HPT-CN |
| Uniform Energy Factor (UEF) | 3.46 | -0.24 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 58 gal | -14 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 938 kWh/yr | -134 kWh/yr vs. 1,072 kWh/yr median | Est. $170/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 373% | -56.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 58.3" H x 28" D | Fits standard 72 in. basement/garage clearance; tight at 28 in. door (28" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 23 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Sound Pressure Level | 54 dBA | +5 dBA vs. 49 dBA median | Indoor placement check |
| Certification Date | 2024-08-13 | Certified 2024-08-13 | Markets: United States, Canada |

## How Do Regional kWh Prices Impact ME50HPT-CN Over 10 Years?

Using EIA Table 5.6.A benchmarks, VAUGHN THERMAL ME50HPT-CN's 938 kWh/yr draw translates to roughly $170/yr on typical US residential bills.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $170/yr | $1,703 | $4,703 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $443/yr | $4,425 | $12,220 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $279/yr | $2,791 | $7,705 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $149/yr | $1,492 | $4,121 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $137/yr | $1,372 | $3,789 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (938 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## What Should VAUGHN THERMAL Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC recall sweep recorded zero brand matches for VAUGHN THERMAL; run a quick serial-number check to verify age before replacing wear parts. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?

Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Hubbell ME50HPT](https://gcsradheat.com/water-heaters/hubbell/me50hpt/) | Hybrid/Electric Heat Pump | 47 gal | 58 gal | 3.46 (at parity) | 938 |
| [Noritz NHP50](https://gcsradheat.com/water-heaters/noritz/nhp50/) | Hybrid/Electric Heat Pump | 47 gal | 58 gal | 3.46 (at parity) | 938 |
| [Carnot Labs, Inc. N51](https://gcsradheat.com/water-heaters/carnot-labs-inc/n51/) | Hybrid/Electric Heat Pump | 47 gal | 75 gal | 3.53 (+0.07) | 1,404 |
| [1HVAC ACIQ-50G-HP-WH](https://gcsradheat.com/water-heaters/1hvac/aciq-50g-hp-wh/) | Hybrid/Electric Heat Pump | 47 gal | 69 gal | 3.75 (+0.29) | 855 |
| [ACIQ ACIQ-50G-HP-WH](https://gcsradheat.com/water-heaters/aciq/aciq-50g-hp-wh/) | Hybrid/Electric Heat Pump | 47 gal | 69 gal | 3.75 (+0.29) | 855 |

## Which Home Setups Are NOT a Fit for VAUGHN THERMAL ME50HPT-CN?

Comparing VAUGHN THERMAL ME50HPT-CN against Hubbell ME50HPT requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

### Key Limitations & Exclusions

- VAUGHN THERMAL ME50HPT-CN needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 54 dBA; avoid mounting VAUGHN THERMAL ME50HPT-CN directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing VAUGHN THERMAL ME50HPT-CN** Strong Fit — 3.46 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare Hubbell ME50HPT footprint.

## Frequently Asked Technical Questions: VAUGHN THERMAL ME50HPT-CN

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### How does VAUGHN THERMAL ME50HPT-CN score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; VAUGHN THERMAL ME50HPT-CN logs 3.46 UEF (Pass: +1.16 / +50.4%) within the 706-unit Hybrid/Electric Heat Pump group.

### What physical clearance dimensions apply when installing VAUGHN THERMAL ME50HPT-CN?

With a 58.3 in. height and 28 in. diameter, VAUGHN THERMAL ME50HPT-CN fits spaces matching: fits standard 72 in. basement/garage clearance; tight at 28 in. door (28" d), plus 6–12 in. above for plumbing shutoffs.

### What 240V circuit or IFGC fuel line capacity fits VAUGHN THERMAL ME50HPT-CN?

Powered via 240V at 23A max, VAUGHN THERMAL ME50HPT-CN requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.

### How do state electricity prices change annual costs for VAUGHN THERMAL ME50HPT-CN?

Annual electric spend for VAUGHN THERMAL ME50HPT-CN (938 kWh/yr) averages $170/yr nationwide (ranging from $137/yr in Washington hydro tiers up to $443/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.

### What homeowner setups should avoid choosing VAUGHN THERMAL ME50HPT-CN?

Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on VAUGHN THERMAL ME50HPT-CN.

### Is VAUGHN THERMAL ME50HPT-CN sized adequately for a 2-to-4-person household?

ENERGY STAR certifies VAUGHN THERMAL ME50HPT-CN at 58 gal First Hour Rating (-14 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.

### Does VAUGHN THERMAL have active CPSC SaferProducts notices affecting ME50HPT-CN?

Zero CPSC recall alerts matched VAUGHN THERMAL (2026-11-23 check). Keep your VAUGHN THERMAL ME50HPT-CN serial code handy to track standard 6-to-12-year OEM warranty coverage.

### Which competing water heater matches VAUGHN THERMAL ME50HPT-CN (3.46 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for VAUGHN THERMAL ME50HPT-CN. Closest peer in Hybrid/Electric Heat Pump is Hubbell ME50HPT (3.46 UEF).

## Essential Pre-Install Guides for VAUGHN THERMAL ME50HPT-CN

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Hubbell ME50HPT (3.46 UEF)→](https://gcsradheat.com/water-heaters/hubbell/me50hpt/)
- [Compare Noritz NHP50 (3.46 UEF)→](https://gcsradheat.com/water-heaters/noritz/nhp50/)
- [View All VAUGHN THERMAL Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/vaughn-thermal/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)