title: "VAUGHN THERMAL MP80F-RC (3.8 UEF, 80 gal)"
url: https://gcsradheat.com/water-heaters/vaughn-thermal/mp80f-rc/
description: "The VAUGHN THERMAL MP80F-RC (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.8 UEF rating across its 80-gallon nominal tank, 98 gal First Hour."
---

ENERGY STAR water heater model · PD 4615175

# VAUGHN THERMAL MP80F-RC Water Heater Specifications (3.8 UEF)

The VAUGHN THERMAL MP80F-RC (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.8 UEF rating across its 80-gallon nominal tank, 98 gal First Hour Rating, ranking #268 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 4615175). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +1.30 / +52.0%. Rated annual electricity draw of 1,273 kWh/yr equates to roughly $231/yr ($2,312 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Reclaim Energy MP80F-RC (3.8 UEF).

- **Uniform Energy Factor**: 3.8 UEF

- **Cohort UEF Rank**: #268 of 706 (top 41.9%)

- **First Hour Rating**: 98 gal

- **Storage Volume**: 80 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.30 / +52.0%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows VAUGHN THERMAL MP80F-RC relative to the cohort median.

Efficiency comparison & rule summary

VAUGHN THERMAL MP80F-RC (3.8 UEF) ranks #268 of 706 Hybrid/Electric Heat Pump models — 29-way tie; top 41.9%, more efficient than 58.1% of Hybrid/Electric Heat Pump models, +0.10 UEF above the 3.70 UEF median.

Federal 2029 margin for VAUGHN THERMAL MP80F-RC: +1.30 UEF (+52.0%) vs. 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,273 kWh/yr for VAUGHN THERMAL MP80F-RC runs ~$231/yr vs. ~$955/yr for a 0.92 UEF electric tank. Acoustic output is 37 dBA (quieter than 93.3% of Hybrid/Electric Heat Pump models).

State electric sensitivity for VAUGHN THERMAL MP80F-RC: 10-year operating spend spans $1,862 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,006 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Peer comparison: VAUGHN THERMAL MP80F-RC (3.8 UEF) compares closely with Reclaim Energy MP80F-RC (3.8 UEF, at parity) and GE Profile PF80S10FPY01 (3.5 UEF, delta -0.30).

## Where Does VAUGHN THERMAL MP80F-RC Rank Against Peer Hybrid/Electric Heat Pump Units?

Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, VAUGHN THERMAL MP80F-RC holds #268 of 706 (top 41.9%); inspect footprint, circuit load, and efficiency deltas here.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [VAUGHN THERMAL](https://gcsradheat.com/brands/vaughn-thermal/) | 13 certified listings | ENERGY STAR PD 4615175 |
| Model Number | MP80F-RC | Draw pattern: High-Usage | MP80F-RC |
| Uniform Energy Factor (UEF) | 3.8 | +0.10 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 98 gal | +26 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,273 kWh/yr | +201 kWh/yr vs. 1,072 kWh/yr median | Est. $231/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 435% | +6.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 53" H x 30" D | Fits standard 72 in. basement/garage clearance; tight at 28 in. door (30" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 6 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-744 (CO₂) (GWP:1 / Lower GWP) | Lower-GWP refrigerant alignment (EPA AIM Act) | EPA AIM Act Compliance |
| Sound Pressure Level | 37 dBA | top 6.7% · quieter than 93.3% of Hybrid/Electric Heat Pump models · -12 dBA vs. 49 dBA median | Indoor placement check |
| Certification Date | 2026-05-21 | Certified 2026-05-21 | Markets: United States, Canada |

## How Much Electricity Does MP80F-RC Use in Different States?

Estimated at $231/yr nationally (1,273 kWh/yr), 10-year utility spending for VAUGHN THERMAL MP80F-RC shifts sharply between low-rate hydro and coastal grids.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $231/yr | $2,312 | $7,237 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $601/yr | $6,006 | $18,801 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $379/yr | $3,787 | $11,855 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $203/yr | $2,025 | $6,340 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $186/yr | $1,862 | $5,830 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (1,273 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Does CPSC Flag Any Safety Notices on VAUGHN THERMAL Units?

No open CPSC recall alerts appeared for VAUGHN THERMAL as of 2026-11-23; you can still decode exact manufacture month and warranty window below. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## Which Competing Hybrid/Electric Heat Pump Models Compare Closest to MP80F-RC?

Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to VAUGHN THERMAL MP80F-RC's gallon capacity and 3.8 UEF efficiency.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Reclaim Energy MP80F-RC](https://gcsradheat.com/water-heaters/reclaim-energy/mp80f-rc/) | Hybrid/Electric Heat Pump | 80 gal | 98 gal | 3.8 (at parity) | 1,273 |
| [GE Profile PF80S10FPY01](https://gcsradheat.com/water-heaters/ge-profile/pf80s10fpy01/) | Hybrid/Electric Heat Pump | 80 gal | 94 gal | 3.5 (-0.30) | 1,417 |
| [Smart Solar SSG2-ES 80](https://gcsradheat.com/water-heaters/smart-solar/ssg2-es-80/) | Hybrid/Electric Heat Pump | 80 gal | 55 gal | 2.71 (-1.09) | 1,192 |
| [A. O. Smith CAHP-80 2**](https://gcsradheat.com/water-heaters/a-o-smith/cahp-80-2/) | Hybrid/Electric Heat Pump | 81 gal | 95 gal | 3.88 (+0.08) | 1,279 |
| [GE Profile PJ80S10FPY01](https://gcsradheat.com/water-heaters/ge-profile/pj80s10fpy01/) | Hybrid/Electric Heat Pump | 80 gal | 94 gal | 3.5 (-0.30) | 1,417 |

## What Are the Limitations of VAUGHN THERMAL MP80F-RC and Who Should Not Install It?

Before ordering VAUGHN THERMAL MP80F-RC (Hybrid/Electric Heat Pump, 3.8 UEF), weigh space clearances, fuel piping, noise (37 dBA), and 2029 rule readiness across three scenarios.

### Key Limitations & Exclusions

- VAUGHN THERMAL MP80F-RC needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 37 dBA; avoid mounting VAUGHN THERMAL MP80F-RC directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing VAUGHN THERMAL MP80F-RC** Strong Fit — 3.8 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare Reclaim Energy MP80F-RC footprint.

## Common Homeowner Questions for VAUGHN THERMAL MP80F-RC

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Does VAUGHN THERMAL MP80F-RC pass the May 6, 2029 federal DOE efficiency rule?

VAUGHN THERMAL MP80F-RC carries a verified 3.8 UEF rating (Pass: +1.30 / +52.0%), ranking #268 of 706 (top 41.9%) across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.

### What doorway width and ceiling height does VAUGHN THERMAL MP80F-RC need?

VAUGHN THERMAL MP80F-RC stands 53 in. high with a 30 in. diameter; fits standard 72 in. basement/garage clearance; tight at 28 in. door (30" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.

### What gas pipe size or electrical breaker does VAUGHN THERMAL MP80F-RC require?

VAUGHN THERMAL MP80F-RC uses a 240V branch circuit at 6A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.

### How much electricity or energy does VAUGHN THERMAL MP80F-RC cost per year to run?

Rated at 1,273 kWh/yr, VAUGHN THERMAL MP80F-RC costs about $231/yr ($2,310 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $186/yr in Washington hydro tiers up to $601/yr in Hawaii).

### Who should NOT install VAUGHN THERMAL MP80F-RC, and what are its limits?

VAUGHN THERMAL MP80F-RC (3.8 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 37 dBA.

### How many bathrooms or people can VAUGHN THERMAL MP80F-RC serve at peak demand?

VAUGHN THERMAL MP80F-RC achieves a 98 gal First Hour Rating (+26 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.

### Are there CPSC safety recalls or serial checks for VAUGHN THERMAL MP80F-RC?

No active CPSC recalls matched VAUGHN THERMAL as of 2026-11-23. Always decode the serial tag on VAUGHN THERMAL MP80F-RC because OEM tank/exchanger warranties span 6–12 years.

### What 2026 rebates apply to VAUGHN THERMAL MP80F-RC, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is Reclaim Energy MP80F-RC (3.8 UEF).

## Next Engineering Checks for VAUGHN THERMAL Owners

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Reclaim Energy MP80F-RC (3.8 UEF)→](https://gcsradheat.com/water-heaters/reclaim-energy/mp80f-rc/)
- [Compare GE Profile PF80S10FPY01 (3.5 UEF)→](https://gcsradheat.com/water-heaters/ge-profile/pf80s10fpy01/)
- [View All VAUGHN THERMAL Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/vaughn-thermal/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)