title: "Fairhope, City Of (AL0000035) Water Quality & PFAS"
url: https://gcsradheat.com/water-quality/alabama/al0000035-fairhope-city-of/
description: "Operating under Local Government management in Fairhope, Alabama, Fairhope, City Of (AL0000035) serves 59,850 residents via ground water. Federal screening."
---

Safe drinking water record · AL0000035

# Fairhope, City Of Water Quality, PFAS & Utility Report (AL0000035)

Operating under Local Government management in Fairhope, Alabama, Fairhope, City Of (AL0000035) serves 59,850 residents via ground water. Federal screening logs show zero EPA health violations alongside 1 monitoring/reporting notice, UCMR 5 samples measured 15.0 ppt for PFOS (exceeding the 4.0 ppt federal rule), making install nsf 58 under-sink ro or nsf 53 pfas carbon the primary home filtration takeaway.

- **EPA PWSID** : AL0000035

- **Population Served** : 59,850

- **Water Source** : Groundwater

- **Max UCMR 5 PFAS** : 15.0 ppt (PFOS)

- **3-Yr Health Flags** : 0 Health Viol.

Local water quality & plumbing fit

Drawing surface water across Fairhope, Fairhope, City Of uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. UCMR 5 samples reached 15.0 ppt for PFOS (at or above EPA's 4.0 ppt enforceable MCL). Prioritize an under-sink NSF/ANSI 58 RO membrane or NSF 53 PFAS-certified block filter for drinking and cooking water.

Across 17,502 housing units in Fairhope, City Of's 1 ZIP code (median value $395,300), 23.6% predates 1980 (7.3% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

## What Should Fairhope Homeowners Know About Fairhope, City Of?

Key federal SDWIS metrics for AL0000035 are tabulated alongside USGS state hardness and pre-1980 building share to guide repipe or filter choices.

EPA SDWA and local housing profile for Fairhope, City Of (AL0000035)

| Water System Parameter | Measured / Reported Value | Benchmark / Federal Limit | Homeowner Impact |
|---|---|---|---|
| EPA Utility ID & Ownership | AL0000035 (Local Government) | Active CWS | Last sanitary visit: 08/08/2025 |
| Primary Source Water | Ground Water | GW vs. SW | Harder mineral load expected |
| Service Area & Population | 59,850 residents | #13 in Alabama | Counties: Baldwin |
| Served ZIP Codes | 36532 | 1 ZIP code | Verify utility on local municipal water bill |
| Pre-1980 Housing Share | 23.6% (7.3% pre-1960) | 1986 Lead Ban | Mostly post-1980 copper or PEX piping |
| 3-Year EPA SDWA Compliance | 1 rule violation (1 qtrs) | Zero health flags target | 4000=Gross Alpha, Excl. Radon And U, 4020=Radium-226, 4030=Radium-228 |
| State Tap Hardness Baseline | Unmonitored in USGS extract | >= 7.0 GPG = Hard | Moderate mineral profile |

## What Does UCMR 5 Testing Reveal About AL0000035?

Review specific PFAS detections, non-detects, and federal 4.0–10 ppt benchmarks recorded for Fairhope, City Of in EPA's national monitoring database.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for AL0000035

| Regulated Compound / Screen | Max Detected | EPA Regulatory Standard | Compliance & Filtration Note |
|---|---|---|---|
| PFOA | 5.7 ppt | 4.0 ppt EPA MCL | Exceeds EPA threshold — NSF 58 RO strongly advised |
| PFOS | 15.0 ppt | 4.0 ppt EPA MCL | Exceeds EPA threshold — NSF 58 RO strongly advised |
| PFHxS | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFNA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| HFPO-DA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |

## Where Can You Compare Fairhope, City Of With Other Alabama Systems?

Four peer Alabama utilities below let homeowners compare municipal groundwater versus surface water exposure across neighboring towns.

Nearby community water systems in Alabama for side-by-side comparison

| Utility Name & PWSID | City / County | Population Served | Primary Source | Health Violations |
|---|---|---|---|---|
| [Decatur, Municipal Ub Of](https://gcsradheat.com/water-quality/alabama/al0001084-decatur-municipal-ub-of/) (AL0001084) | Decatur | 77,103 | Surface / Mixed | 0 |
| [Auburn, The Ww Board Of The City Of](https://gcsradheat.com/water-quality/alabama/al0000804-auburn-the-ww-board-of-the-city-of/) (AL0000804) | Auburn | 74,292 | Surface / Mixed | 0 |
| [Cullman County Water Department](https://gcsradheat.com/water-quality/alabama/al0000394-cullman-county-water-department/) (AL0000394) | Cullman | 57,006 | Surface / Mixed | 0 |
| [Anniston Alabama, The Wwsb Of The City O](https://gcsradheat.com/water-quality/alabama/al0000133-anniston-alabama-the-wwsb-of-the-city-o/) (AL0000133) | Anniston | 56,865 | Surface / Mixed | 0 |

## When Should Fairhope, City Of Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Fairhope; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

### Key Limitations & Exclusions

- Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
- Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
- Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

### Which Option Fits Your Situation?

**Pre-1980 Home or Young Family** Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.

**Installing a New Tankless Water Heater** Check tap hardness (7+ GPG) and add scale inhibition on groundwater feeds.

## Common Questions for Fairhope, City Of Tap Water Customers

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Is tap water from Fairhope, City Of surface-treated or well-sourced?

EPA ECHO classifies Fairhope, City Of (AL0000035) as a Ground Water community system serving 59,850 residents across Baldwin. Groundwater supplies draw from subsurface aquifers and typically carry higher dissolved calcium and magnesium carbonate, making annual tank flushing and scale protection important.

### Did Fairhope, City Of exceed EPA's 4.0 ppt PFOA or PFOS standard?

Yes—UCMR 5 laboratory testing for AL0000035 recorded 4 PFAS detections peaking at 15.0 ppt (PFOS), which sits at or above EPA's 4.0 ppt enforceable MCL. NSF/ANSI 58 reverse osmosis or NSF 53 PFAS-rated carbon effectively reduces exposure at the drinking tap.

### Are pre-1980 copper solder or galvanized lines common in Fairhope, City Of's ZIP codes?

Across the 1 ZIP codes served by Fairhope, City Of, approximately 23.6% of residential housing units were built before 1980 (7.3% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

## Explore Alabama Counties, Softeners & Water Heaters

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Decatur, Municipal Ub Of (AL0001084)→](https://gcsradheat.com/water-quality/alabama/al0001084-decatur-municipal-ub-of/)
- [Compare Auburn, The Ww Board Of The City Of (AL0000804)→](https://gcsradheat.com/water-quality/alabama/al0000804-auburn-the-ww-board-of-the-city-of/)
- [Browse All Alabama Community Water Utilities→](https://gcsradheat.com/water-quality/alabama/)
- [Inspect Alabama County Well, Freeze & Pipe Data→](https://gcsradheat.com/counties/alabama/)
- [Check Well Water PFAS, Radon & Filtration Guide→](https://gcsradheat.com/guides/well-water-filtration-radon-pfas/)

## Sources

1. [EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download](https://echo.epa.gov/tools/data-downloads) — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
2. [Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State](https://www.epa.gov/dwucmr/occurrence-data-unregulated-contaminant-monitoring-rule) — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
3. [PFAS National Primary Drinking Water Regulation & LCRI Overview](https://www.epa.gov/sdwa/and-polyfluoroalkyl-substances-pfas) — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
4. [Lead and Copper Rule Improvements (LCRI) & Service Line Inventories](https://www.epa.gov/ground-water-and-drinking-water/lead-and-copper-rule-improvements) — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
5. [National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg)](https://www.waterqualitydata.us/data/Result/search) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
6. [U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File](https://www2.census.gov/programs-surveys/acs/summary_file/2023/table-based-SF/) — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Tap Checklist (AL0000035)

### Point-of-Use Reverse Osmosis (NSF/ANSI 58) or Catalytic Carbon (NSF 53)

Annual water heater flushing and install nsf 58 under-sink ro or nsf 53 pfas carbon help protect fixtures across 1 Fairhope ZIP codes.
[All Alabama Utilities](https://gcsradheat.com/water-quality/alabama/) [Check Softener Grain Sizing](https://gcsradheat.com/tools/water-softener-calculator/)