title: "Chisholm Heights, Water & F P Authority (AL0000777) Water"
url: https://gcsradheat.com/water-quality/alabama/al0000777-chisholm-heights-water-f-p-authority/
description: "Ranked #231 of 304 major community water utilities in Alabama, Chisholm Heights, Water & F P Authority (AL0000777) delivers surface water purchased to 4,881."
---

EPA SDWA profile · AL0000777 (Alabama)

# Chisholm Heights, Water & F P Authority Water Quality, PFAS & Utility Report (AL0000777)

Ranked #231 of 304 major community water utilities in Alabama, Chisholm Heights, Water & F P Authority (AL0000777) delivers surface water purchased to 4,881 people around Florence. Public records indicate zero EPA health violations alongside 5 monitoring/reporting notices and note that UCMR 5 samples measured 9.6 ppt for PFOS (exceeding the 4.0 ppt federal rule). Recommended home check: Install NSF 58 under-sink RO or NSF 53 PFAS carbon.

- **EPA PWSID** : AL0000777

- **Population Served** : 4,881

- **Water Source** : Surface Water

- **Max UCMR 5 PFAS** : 9.6 ppt (PFOS)

- **3-Yr Health Flags** : 0 Health Viol.

Homeowner takeaway for AL0000777

Drawing surface water across Florence, Chisholm Heights, Water & F P Authority uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. UCMR 5 samples reached 9.6 ppt for PFOS (at or above EPA's 4.0 ppt enforceable MCL). Prioritize an under-sink NSF/ANSI 58 RO membrane or NSF 53 PFAS-certified block filter for drinking and cooking water.

Across 17,371 housing units in Chisholm Heights, Water & F P Authority's 1 ZIP code (median value $153,300), 65.4% predates 1980 (31.1% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

## Which Compliance and Housing Indicators Define AL0000777?

These verified utility measurements pair EPA SDWIS facility data for Chisholm Heights, Water & F P Authority with Census housing vintage across its 1 served ZIP codes.

EPA SDWA and local housing profile for Chisholm Heights, Water & F P Authority (AL0000777)

| Water System Parameter | Measured / Reported Value | Benchmark / Federal Limit | Homeowner Impact |
|---|---|---|---|
| EPA Utility ID & Ownership | AL0000777 (Local Government) | Active CWS | Last sanitary visit: 05/19/2026 |
| Primary Source Water | Surface Water Purchased | GW vs. SW | Disinfection byproduct check recommended |
| Service Area & Population | 4,881 residents | #231 in Alabama | Counties: Lauderdale |
| Served ZIP Codes | 35630 | 1 ZIP code | Verify utility on local municipal water bill |
| Pre-1980 Housing Share | 65.4% (31.1% pre-1960) | 1986 Lead Ban | Higher likelihood of legacy lead solder or galvanized laterals |
| 3-Year EPA SDWA Compliance | 5 rule violations (12 qtrs) | Zero health flags target | 2456=Total Haloacetic Acids (Haa5), 2950=Tthm, 7000=Consumer Confidence Rule, 8000=Revised Total Coliform Rule |
| State Tap Hardness Baseline | Unmonitored in USGS extract | >= 7.0 GPG = Hard | Moderate mineral profile |

## How Do Chisholm Heights, Water & F P Authority PFAS Levels Stack Up Against 4.0 ppt Rules?

EPA's National Primary Drinking Water Regulation sets strict 4.0 ppt limits on PFOA and PFOS; inspect Chisholm Heights, Water & F P Authority's monitored results below.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for AL0000777

| Regulated Compound / Screen | Max Detected | EPA Regulatory Standard | Compliance & Filtration Note |
|---|---|---|---|
| PFOA | 5.2 ppt | 4.0 ppt EPA MCL | Exceeds EPA threshold — NSF 58 RO strongly advised |
| PFOS | 9.6 ppt | 4.0 ppt EPA MCL | Exceeds EPA threshold — NSF 58 RO strongly advised |
| PFHxS | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFNA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| HFPO-DA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |

## What Do Neighboring Community Water Systems Report in Alabama?

Cross-check four peer Alabama water utilities to see how Chisholm Heights, Water & F P Authority ranks by system size, groundwater reliance, and EPA notices.

Nearby community water systems in Alabama for side-by-side comparison

| Utility Name & PWSID | City / County | Population Served | Primary Source | Health Violations |
|---|---|---|---|---|
| [Houston County Water Authority](https://gcsradheat.com/water-quality/alabama/al0001755-houston-county-water-authority/) (AL0001755) | Dothan | 4,902 | Groundwater | 0 |
| [Berry, Town Of](https://gcsradheat.com/water-quality/alabama/al0000596-berry-town-of/) (AL0000596) | Berry | 4,887 | Surface / Mixed | 0 |
| [Boldo, Water & Fire Protection Authority](https://gcsradheat.com/water-quality/alabama/al0001322-boldo-water-fire-protection-authority/) (AL0001322) | Jasper | 4,857 | Surface / Mixed | 0 |
| [Eutaw Water Department](https://gcsradheat.com/water-quality/alabama/al0000636-eutaw-water-department/) (AL0000636) | Eutaw | 4,764 | Groundwater | 0 |

## When Should Chisholm Heights, Water & F P Authority Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Florence; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

### Key Limitations & Exclusions

- Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
- Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
- Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

### Which Option Fits Your Situation?

**Pre-1980 Home or Young Family** Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.

**Installing a New Tankless Water Heater** Check tap hardness (7+ GPG) and add scale inhibition on groundwater feeds.

## Key Questions About Tap Water From Chisholm Heights, Water & F P Authority

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### What water source serves the 4,881 customers under EPA ID AL0000777?

EPA ECHO classifies Chisholm Heights, Water & F P Authority (AL0000777) as a Surface Water Purchased community system serving 4,881 residents across Lauderdale. Surface supplies pull from rivers, lakes, or reservoirs and require chlorine or chloramine disinfection plus monitoring for disinfection byproducts.

### How do Chisholm Heights, Water & F P Authority PFAS levels compare to EPA's 4.0 ppt federal limit?

Yes—UCMR 5 laboratory testing for AL0000777 recorded 4 PFAS detections peaking at 9.6 ppt (PFOS), which sits at or above EPA's 4.0 ppt enforceable MCL. NSF/ANSI 58 reverse osmosis or NSF 53 PFAS-rated carbon effectively reduces exposure at the drinking tap.

### What pipe materials should homeowners served by Chisholm Heights, Water & F P Authority inspect?

Across the 1 ZIP codes served by Chisholm Heights, Water & F P Authority, approximately 65.4% of residential housing units were built before 1980 (31.1% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

## Additional Water Softener & Code Tools for AL

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Houston County Water Authority (AL0001755)→](https://gcsradheat.com/water-quality/alabama/al0001755-houston-county-water-authority/)
- [Compare Berry, Town Of (AL0000596)→](https://gcsradheat.com/water-quality/alabama/al0000596-berry-town-of/)
- [Browse All Alabama Community Water Utilities→](https://gcsradheat.com/water-quality/alabama/)
- [Inspect Alabama County Well, Freeze & Pipe Data→](https://gcsradheat.com/counties/alabama/)
- [Check Well Water PFAS, Radon & Filtration Guide→](https://gcsradheat.com/guides/well-water-filtration-radon-pfas/)

## Sources

1. [EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download](https://echo.epa.gov/tools/data-downloads) — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
2. [Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State](https://www.epa.gov/dwucmr/occurrence-data-unregulated-contaminant-monitoring-rule) — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
3. [PFAS National Primary Drinking Water Regulation & LCRI Overview](https://www.epa.gov/sdwa/and-polyfluoroalkyl-substances-pfas) — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
4. [Lead and Copper Rule Improvements (LCRI) & Service Line Inventories](https://www.epa.gov/ground-water-and-drinking-water/lead-and-copper-rule-improvements) — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
5. [National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg)](https://www.waterqualitydata.us/data/Result/search) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
6. [U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File](https://www2.census.gov/programs-surveys/acs/summary_file/2023/table-based-SF/) — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Filter Spec (AL)

### Point-of-Use Reverse Osmosis (NSF/ANSI 58) or Catalytic Carbon (NSF 53)

Serving Florence via surface water; confirm cartridge micron & NSF 53/58 certifications locally.
[All Alabama Utilities](https://gcsradheat.com/water-quality/alabama/) [Check Softener Grain Sizing](https://gcsradheat.com/tools/water-softener-calculator/)