title: "Pelham, City Of (AL0001163) Water Quality & PFAS"
url: https://gcsradheat.com/water-quality/alabama/al0001163-pelham-city-of/
description: "Supplying 38,703 customers across Shelby, Alabama, Pelham, City Of (EPA ID AL0001163) relies on surface water purchased for daily municipal flow. Current."
---

Utility quality file · Pelham, AL (AL0001163)

# Pelham, City Of Water Quality, PFAS & Utility Report (AL0001163)

Supplying 38,703 customers across Shelby, Alabama, Pelham, City Of (EPA ID AL0001163) relies on surface water purchased for daily municipal flow. Current federal compliance files record zero EPA health violations alongside 1 monitoring/reporting notice; meanwhile UCMR 5 samples measured 64.3 ppt for PFBS (exceeding the 4.0 ppt federal rule), and 19.0% of homes across 1 served ZIP code predate 1980.

- **EPA PWSID** : AL0001163

- **Population Served** : 38,703

- **Water Source** : Surface Water

- **Max UCMR 5 PFAS** : 64.3 ppt (PFBS)

- **3-Yr Health Flags** : 0 Health Viol.

Tap treatment summary — AL0001163

Drawing surface water across Pelham, Pelham, City Of uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. UCMR 5 samples reached 64.3 ppt for PFBS (at or above EPA's 4.0 ppt enforceable MCL). Prioritize an under-sink NSF/ANSI 58 RO membrane or NSF 53 PFAS-certified block filter for drinking and cooking water.

Across 10,207 housing units in Pelham, City Of's 1 ZIP code (median value $282,600), 19.0% predates 1980 (1.6% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

## How Is Pelham, City Of's Municipal Water Supplied and Regulated?

Review Pelham, City Of's supply classification, customer headcount, local pre-1980 housing density, and 3-year Safe Drinking Water Act inspection metrics below.

EPA SDWA and local housing profile for Pelham, City Of (AL0001163)

| Water System Parameter | Measured / Reported Value | Benchmark / Federal Limit | Homeowner Impact |
|---|---|---|---|
| EPA Utility ID & Ownership | AL0001163 (Local Government) | Active CWS | Last sanitary visit: 07/20/2023 |
| Primary Source Water | Surface Water Purchased | GW vs. SW | Disinfection byproduct check recommended |
| Service Area & Population | 38,703 residents | #35 in Alabama | Counties: Shelby |
| Served ZIP Codes | 35124 | 1 ZIP code | Verify utility on local municipal water bill |
| Pre-1980 Housing Share | 19.0% (1.6% pre-1960) | 1986 Lead Ban | Mostly post-1980 copper or PEX piping |
| 3-Year EPA SDWA Compliance | 1 rule violation (1 qtrs) | Zero health flags target | 2378=1, 2, 4-Trichlorobenzene, 2380=Cis-1 |
| State Tap Hardness Baseline | Unmonitored in USGS extract | >= 7.0 GPG = Hard | Moderate mineral profile |

## What Do Federal PFAS Lab Results Show for Pelham, City Of?

See how Pelham, City Of (AL0001163) performed across federal UCMR 5 compounds alongside EPA's 4.0 ppt enforcement standard for PFOA and PFOS.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for AL0001163

| Regulated Compound / Screen | Max Detected | EPA Regulatory Standard | Compliance & Filtration Note |
|---|---|---|---|
| PFOA | 11.6 ppt | 4.0 ppt EPA MCL | Exceeds EPA threshold — NSF 58 RO strongly advised |
| PFOS | 5.6 ppt | 4.0 ppt EPA MCL | Exceeds EPA threshold — NSF 58 RO strongly advised |
| PFHxS | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFNA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| HFPO-DA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |

## Which Nearby Alabama Water Utilities Match This Profile?

Compare population scale, water source, and compliance status across four comparable community systems operating in Alabama.

Nearby community water systems in Alabama for side-by-side comparison

| Utility Name & PWSID | City / County | Population Served | Primary Source | Health Violations |
|---|---|---|---|---|
| [Mobile County Water & Fire Pro Authority](https://gcsradheat.com/water-quality/alabama/al0001002-mobile-county-water-fire-pro-authority/) (AL0001002) | Theodore | 39,573 | Groundwater | 0 |
| [South Alabama Utilities Water System](https://gcsradheat.com/water-quality/alabama/al0000967-south-alabama-utilities-water-system/) (AL0000967) | Citronelle | 39,249 | Groundwater | 0 |
| [Warrior River Water Authority](https://gcsradheat.com/water-quality/alabama/al0000763-warrior-river-water-authority/) (AL0000763) | Bessemer | 38,700 | Surface / Mixed | 0 |
| [Cullman, City Of](https://gcsradheat.com/water-quality/alabama/al0001786-cullman-city-of/) (AL0001786) | Cullman | 36,741 | Surface / Mixed | 0 |

## When Should Pelham, City Of Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Pelham; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

### Key Limitations & Exclusions

- Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
- Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
- Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

### Which Option Fits Your Situation?

**Pre-1980 Home or Young Family** Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.

**Installing a New Tankless Water Heater** Check tap hardness (7+ GPG) and add scale inhibition on groundwater feeds.

## Practical Drinking Water Questions for Pelham Residents

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Does Pelham, City Of draw from groundwater aquifers or surface water reservoirs?

EPA ECHO classifies Pelham, City Of (AL0001163) as a Surface Water Purchased community system serving 38,703 residents across Shelby. Surface supplies pull from rivers, lakes, or reservoirs and require chlorine or chloramine disinfection plus monitoring for disinfection byproducts.

### What did federal UCMR 5 sampling measure in AL0001163?

Yes—UCMR 5 laboratory testing for AL0001163 recorded 15 PFAS detections peaking at 64.3 ppt (PFBS), which sits at or above EPA's 4.0 ppt enforceable MCL. NSF/ANSI 58 reverse osmosis or NSF 53 PFAS-rated carbon effectively reduces exposure at the drinking tap.

### How does local home age affect plumbing risk inside AL0001163's service area?

Across the 1 ZIP codes served by Pelham, City Of, approximately 19.0% of residential housing units were built before 1980 (1.6% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

## Related Alabama Pipe & Softener Links

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Mobile County Water & Fire Pro Authority (AL0001002)→](https://gcsradheat.com/water-quality/alabama/al0001002-mobile-county-water-fire-pro-authority/)
- [Compare South Alabama Utilities Water System (AL0000967)→](https://gcsradheat.com/water-quality/alabama/al0000967-south-alabama-utilities-water-system/)
- [Browse All Alabama Community Water Utilities→](https://gcsradheat.com/water-quality/alabama/)
- [Inspect Alabama County Well, Freeze & Pipe Data→](https://gcsradheat.com/counties/alabama/)
- [Check Well Water PFAS, Radon & Filtration Guide→](https://gcsradheat.com/guides/well-water-filtration-radon-pfas/)

## Sources

1. [EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download](https://echo.epa.gov/tools/data-downloads) — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
2. [Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State](https://www.epa.gov/dwucmr/occurrence-data-unregulated-contaminant-monitoring-rule) — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
3. [PFAS National Primary Drinking Water Regulation & LCRI Overview](https://www.epa.gov/sdwa/and-polyfluoroalkyl-substances-pfas) — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
4. [Lead and Copper Rule Improvements (LCRI) & Service Line Inventories](https://www.epa.gov/ground-water-and-drinking-water/lead-and-copper-rule-improvements) — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
5. [National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg)](https://www.waterqualitydata.us/data/Result/search) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
6. [U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File](https://www2.census.gov/programs-surveys/acs/summary_file/2023/table-based-SF/) — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Pelham Tap Action

### Point-of-Use Reverse Osmosis (NSF/ANSI 58) or Catalytic Carbon (NSF 53)

For 38,703 customers on surface water, focus on install nsf 58 under-sink ro or nsf 53 pfas carbon before upgrading heaters.
[All Alabama Utilities](https://gcsradheat.com/water-quality/alabama/) [Check Softener Grain Sizing](https://gcsradheat.com/tools/water-softener-calculator/)