---
title: "Moa Municipality Of Anchorage (AK2210906) Water Quality"
url: https://gcsradheat.com/water-quality/alaska/ak2210906-moa-municipality-of-anchorage/
description: "Homeowners connected to Moa Municipality Of Anchorage (AK2210906) in Anchorage, Alaska receive surface water across a 221,351-person distribution network. EPA."
---

Community water audit · AK2210906 in AK

# Moa Municipality Of Anchorage Water Quality, PFAS & Utility Report (AK2210906)

Homeowners connected to Moa Municipality Of Anchorage (AK2210906) in Anchorage, Alaska receive surface water across a 221,351-person distribution network. EPA SDWIS records document zero EPA health violations alongside 1 monitoring/reporting notice; under UCMR 5 monitoring, UCMR 5 samples measured 11.2 ppt for PFHxS (exceeding the 4.0 ppt federal rule), and 45.8% of homes across 11 served ZIP codes predate 1980.

- **EPA PWSID** : AK2210906

- **Population Served** : 221,351

- **Water Source** : Surface Water

- **Max UCMR 5 PFAS** : 11.2 ppt (PFHxS)

- **3-Yr Health Flags** : 0 Health Viol.

Water chemistry briefing — Moa Municipality Of Anchorage

Drawing surface water across Anchorage, Moa Municipality Of Anchorage uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. UCMR 5 samples reached 11.2 ppt for PFHxS (at or above EPA's 4.0 ppt enforceable MCL). Prioritize an under-sink NSF/ANSI 58 RO membrane or NSF 53 PFAS-certified block filter for drinking and cooking water.

Across 110,148 housing units in Moa Municipality Of Anchorage's 11 ZIP codes (median value $389,645), 45.8% predates 1980 (7.7% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

## How Clean and Hard Is Tap Water Supplied by Moa Municipality Of Anchorage?

Examine Moa Municipality Of Anchorage's raw source water category, historical SDWA violations, and pre-1980 neighborhood pipe exposure in Anchorage Municipality.

EPA SDWA and local housing profile for Moa Municipality Of Anchorage (AK2210906)

| Water System Parameter | Measured / Reported Value | Benchmark / Federal Limit | Homeowner Impact |
|---|---|---|---|
| EPA Utility ID & Ownership | AK2210906 (Local Government) | Active CWS | Last sanitary visit: 10/16/2025 |
| Primary Source Water | Surface Water | GW vs. SW | Disinfection byproduct check recommended |
| Service Area & Population | 221,351 residents | #1 in Alaska | Counties: Anchorage Municipality |
| Served ZIP Codes | 99501, 99502, 99503, 99504, 99507, 99508, 99515, 99516 (+3 more) | 11 ZIP codes | Verify utility on local municipal water bill |
| Pre-1980 Housing Share | 45.8% (7.7% pre-1960) | 1986 Lead Ban | Higher likelihood of legacy lead solder or galvanized laterals |
| 3-Year EPA SDWA Compliance | 1 rule violation (1 qtrs) | Zero health flags target | No health-based compliance flags |
| State Tap Hardness Baseline | Unmonitored in USGS extract | >= 7.0 GPG = Hard | Moderate mineral profile |

## Are Forever Chemicals Detected in Moa Municipality Of Anchorage Distribution Lines?

Federal UCMR 5 screening tracks synthetic PFAS compounds across US community utilities; verify AK2210906's maximum detections compound by compound.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for AK2210906

| Regulated Compound / Screen | Max Detected | EPA Regulatory Standard | Compliance & Filtration Note |
|---|---|---|---|
| PFOA | 9.1 ppt | 4.0 ppt EPA MCL | Exceeds EPA threshold — NSF 58 RO strongly advised |
| PFOS | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFHxS | 11.2 ppt | 10 ppt EPA MCL | Exceeds EPA threshold — NSF 58 RO strongly advised |
| PFNA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| HFPO-DA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |

## Who Are the Closest Alaska Community System Peers?

Compare four other Alaska utilities of comparable population scale to benchmark source protection and treatment performance.

Nearby community water systems in Alaska for side-by-side comparison

| Utility Name & PWSID | City / County | Population Served | Primary Source | Health Violations |
|---|---|---|---|---|
| [Nome Joint Utility System](https://gcsradheat.com/water-quality/alaska/ak2340010-nome-joint-utility-system/) (AK2340010) | Nome | 3,920 | Groundwater | 0 |
| [Seward](https://gcsradheat.com/water-quality/alaska/ak2240757-seward/) (AK2240757) | Seward | 3,324 | Groundwater | 1 |
| [Golden Heart Utilities](https://gcsradheat.com/water-quality/alaska/ak2310730-golden-heart-utilities/) (AK2310730) | Fairbanks | 78,324 | Groundwater | 0 |
| [City And Borough Of Juneau](https://gcsradheat.com/water-quality/alaska/ak2110342-city-and-borough-of-juneau/) (AK2110342) | Juneau | 38,526 | Surface / Mixed | 0 |

## When Should Moa Municipality Of Anchorage Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Anchorage; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

### Key Limitations & Exclusions

- Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
- Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
- Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

### Which Option Fits Your Situation?

**Pre-1980 Home or Young Family** Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.

**Installing a New Tankless Water Heater** Check tap hardness (7+ GPG) and add scale inhibition on groundwater feeds.

## Drinking Water & Pipe Safety FAQs: AK2210906

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### How does Moa Municipality Of Anchorage's supply type affect hardness and scale in home plumbing?

EPA ECHO classifies Moa Municipality Of Anchorage (AK2210906) as a Surface Water community system serving 221,351 residents across Anchorage Municipality. Surface supplies pull from rivers, lakes, or reservoirs and require chlorine or chloramine disinfection plus monitoring for disinfection byproducts.

### Should Moa Municipality Of Anchorage homeowners filter tap water for PFAS forever chemicals?

Yes—UCMR 5 laboratory testing for AK2210906 recorded 5 PFAS detections peaking at 11.2 ppt (PFHxS), which sits at or above EPA's 4.0 ppt enforceable MCL. NSF/ANSI 58 reverse osmosis or NSF 53 PFAS-rated carbon effectively reduces exposure at the drinking tap.

### Does EPA's 10 ppb LCRI lead rule apply to houses on Moa Municipality Of Anchorage?

Across the 11 ZIP codes served by Moa Municipality Of Anchorage, approximately 45.8% of residential housing units were built before 1980 (7.7% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

## State Plumbing & Water Hardness Tools for Alaska

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Nome Joint Utility System (AK2340010)→](https://gcsradheat.com/water-quality/alaska/ak2340010-nome-joint-utility-system/)
- [Compare Seward (AK2240757)→](https://gcsradheat.com/water-quality/alaska/ak2240757-seward/)
- [Browse All Alaska Community Water Utilities→](https://gcsradheat.com/water-quality/alaska/)
- [Inspect Alaska County Well, Freeze & Pipe Data→](https://gcsradheat.com/counties/alaska/)
- [Check Well Water PFAS, Radon & Filtration Guide→](https://gcsradheat.com/guides/well-water-filtration-radon-pfas/)

## Sources

1. [EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download](https://echo.epa.gov/tools/data-downloads) — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
2. [Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State](https://www.epa.gov/dwucmr/occurrence-data-unregulated-contaminant-monitoring-rule) — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
3. [PFAS National Primary Drinking Water Regulation & LCRI Overview](https://www.epa.gov/sdwa/and-polyfluoroalkyl-substances-pfas) — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
4. [Lead and Copper Rule Improvements (LCRI) & Service Line Inventories](https://www.epa.gov/ground-water-and-drinking-water/lead-and-copper-rule-improvements) — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
5. [National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg)](https://www.waterqualitydata.us/data/Result/search) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
6. [U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File](https://www2.census.gov/programs-surveys/acs/summary_file/2023/table-based-SF/) — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Protection Priority

### Point-of-Use Reverse Osmosis (NSF/ANSI 58) or Catalytic Carbon (NSF 53)

EPA AK2210906 serves 221,351 people; match drinking tap filters and scale prevention to Anchorage water.
[All Alaska Utilities](https://gcsradheat.com/water-quality/alaska/) [Check Softener Grain Sizing](https://gcsradheat.com/tools/water-softener-calculator/)
