---
title: "Blue Lake Springs Mut Wtr (CA0510009) Water Quality & PFAS"
url: https://gcsradheat.com/water-quality/california/ca0510009-blue-lake-springs-mut-wtr/
description: "Homeowners connected to Blue Lake Springs Mut Wtr (CA0510009) in Calaveras, California receive surface water purchased across a 4,822-person distribution."
---

Community water audit · CA0510009 in CA

# Blue Lake Springs Mut Wtr Water Quality, PFAS & Utility Report (CA0510009)

Homeowners connected to Blue Lake Springs Mut Wtr (CA0510009) in Calaveras, California receive surface water purchased across a 4,822-person distribution network. EPA SDWIS records document zero 3-year EPA health or monitoring rule violations on record; under UCMR 5 monitoring, all 180 federal UCMR 5 PFAS lab runs tested non-detect, and 42.4% of homes across 1 served ZIP code predate 1980.

- **EPA PWSID** : CA0510009

- **Population Served** : 4,822

- **Water Source** : Surface Water

- **Max UCMR 5 PFAS** : 0 ppt Detected

- **3-Yr Health Flags** : 0 Health Viol.

Water chemistry briefing — Blue Lake Springs Mut Wtr

Drawing surface water across Calaveras, Blue Lake Springs Mut Wtr uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. Surface water utilities disinfect with chlorine or chloramines; catalytic carbon cartridges remove taste, odor, and trihalomethane (TTHM) byproducts at the kitchen tap.

Across 7,273 housing units in Blue Lake Springs Mut Wtr's 1 ZIP code (median value $475,800), 42.4% predates 1980 (8.6% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

## How Clean and Hard Is Tap Water Supplied by Blue Lake Springs Mut Wtr?

Examine Blue Lake Springs Mut Wtr's raw source water category, historical SDWA violations, and pre-1980 neighborhood pipe exposure in Calaveras.

EPA SDWA and local housing profile for Blue Lake Springs Mut Wtr (CA0510009)

| Water System Parameter | Measured / Reported Value | Benchmark / Federal Limit | Homeowner Impact |
|---|---|---|---|
| EPA Utility ID & Ownership | CA0510009 (Private) | Active CWS | Last sanitary visit: 10/03/2023 |
| Primary Source Water | Surface Water Purchased | GW vs. SW | Disinfection byproduct check recommended |
| Service Area & Population | 4,822 residents | #581 in California | Counties: Calaveras |
| Served ZIP Codes | 95223 | 1 ZIP code | Verify utility on local municipal water bill |
| Pre-1980 Housing Share | 42.4% (8.6% pre-1960) | 1986 Lead Ban | Higher likelihood of legacy lead solder or galvanized laterals |
| 3-Year EPA SDWA Compliance | 0 rule violations (0 qtrs) | Zero health flags target | No health-based compliance flags |
| State Tap Hardness Baseline | 36.1 GPG (Very Hard) | >= 7.0 GPG = Hard | Size ion-exchange resin on local grain test |

## Are Forever Chemicals Detected in Blue Lake Springs Mut Wtr Distribution Lines?

Federal UCMR 5 screening tracks synthetic PFAS compounds across US community utilities; verify CA0510009's maximum detections compound by compound.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for CA0510009

| Regulated Compound / Screen | Max Detected | EPA Regulatory Standard | Compliance & Filtration Note |
|---|---|---|---|
| PFOA | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFOS | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFHxS | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFNA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| HFPO-DA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| Lead / Copper 90th Pct | Pb: 1 / Cu: — | 10 ppb Lead (LCRI) / 1.3 ppm Cu | Utility distribution sample |

## Who Are the Closest California Community System Peers?

Compare four other California utilities of comparable population scale to benchmark source protection and treatment performance.

Nearby community water systems in California for side-by-side comparison

| Utility Name & PWSID | City / County | Population Served | Primary Source | Health Violations |
|---|---|---|---|---|
| [La Cumbre Mutual Water Co](https://gcsradheat.com/water-quality/california/ca4210024-la-cumbre-mutual-water-co/) (CA4210024) | Santa Barbara | 4,861 | Surface / Mixed | 0 |
| [Sswd - Del Paso Manor Service Area](https://gcsradheat.com/water-quality/california/ca3410007-sswd-del-paso-manor-service-area/) (CA3410007) | Sacramento | 4,854 | Groundwater | 0 |
| [Calipatria State Prison](https://gcsradheat.com/water-quality/california/ca1310800-calipatria-state-prison/) (CA1310800) | Imperial | 4,800 | Surface / Mixed | 0 |
| [Los Angeles Cwwd 37-Acton](https://gcsradheat.com/water-quality/california/ca1910248-los-angeles-cwwd-37-acton/) (CA1910248) | Los Angeles | 4,782 | Surface / Mixed | 0 |

## When Should Blue Lake Springs Mut Wtr Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Calaveras; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

### Key Limitations & Exclusions

- Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
- Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
- Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

### Which Option Fits Your Situation?

**Pre-1980 Home or Young Family** Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.

**Installing a New Tankless Water Heater** Check tap hardness (36.1 GPG) and add scale inhibition on groundwater feeds.

## Drinking Water & Pipe Safety FAQs: CA0510009

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### How does Blue Lake Springs Mut Wtr's supply type affect hardness and scale in home plumbing?

EPA ECHO classifies Blue Lake Springs Mut Wtr (CA0510009) as a Surface Water Purchased community system serving 4,822 residents across Calaveras. Surface supplies pull from rivers, lakes, or reservoirs and require chlorine or chloramine disinfection plus monitoring for disinfection byproducts.

### Should Blue Lake Springs Mut Wtr homeowners filter tap water for PFAS forever chemicals?

Federal UCMR 5 sampling covering 180 laboratory tests for Blue Lake Springs Mut Wtr reported zero quantifiable PFAS compounds above reporting limits, well under the 4.0 ppt federal PFOA/PFOS rule.

### Does EPA's 10 ppb LCRI lead rule apply to houses on Blue Lake Springs Mut Wtr?

Across the 1 ZIP codes served by Blue Lake Springs Mut Wtr, approximately 42.4% of residential housing units were built before 1980 (8.6% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

## State Plumbing & Water Hardness Tools for California

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare La Cumbre Mutual Water Co (CA4210024)→](https://gcsradheat.com/water-quality/california/ca4210024-la-cumbre-mutual-water-co/)
- [Compare Sswd - Del Paso Manor Service Area (CA3410007)→](https://gcsradheat.com/water-quality/california/ca3410007-sswd-del-paso-manor-service-area/)
- [Browse All California Community Water Utilities→](https://gcsradheat.com/water-quality/california/)
- [Inspect California County Well, Freeze & Pipe Data→](https://gcsradheat.com/counties/california/)
- [Check Well Water PFAS, Radon & Filtration Guide→](https://gcsradheat.com/guides/well-water-filtration-radon-pfas/)

## Sources

1. [EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download](https://echo.epa.gov/tools/data-downloads) — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
2. [Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State](https://www.epa.gov/dwucmr/occurrence-data-unregulated-contaminant-monitoring-rule) — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
3. [PFAS National Primary Drinking Water Regulation & LCRI Overview](https://www.epa.gov/sdwa/and-polyfluoroalkyl-substances-pfas) — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
4. [Lead and Copper Rule Improvements (LCRI) & Service Line Inventories](https://www.epa.gov/ground-water-and-drinking-water/lead-and-copper-rule-improvements) — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
5. [National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg)](https://www.waterqualitydata.us/data/Result/search) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
6. [U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File](https://www2.census.gov/programs-surveys/acs/summary_file/2023/table-based-SF/) — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Protection Priority

### NSF/ANSI 42/53 Carbon Block for Chloramine / Disinfection Byproducts

EPA CA0510009 serves 4,822 people; match drinking tap filters and scale prevention to Calaveras water.
[All California Utilities](https://gcsradheat.com/water-quality/california/) [Check Softener Grain Sizing](https://gcsradheat.com/tools/water-softener-calculator/)
