---
title: "Cal Am - Meadowbrook (CA2410008) Water Quality & PFAS"
url: https://gcsradheat.com/water-quality/california/ca2410008-cal-am-meadowbrook/
description: "Homeowners connected to Cal Am - Meadowbrook (CA2410008) in Merced, California receive ground water across a 5,723-person distribution network. EPA SDWIS."
---

Community water audit · CA2410008 in CA

# Cal Am - Meadowbrook Water Quality, PFAS & Utility Report (CA2410008)

Homeowners connected to Cal Am - Meadowbrook (CA2410008) in Merced, California receive ground water across a 5,723-person distribution network. EPA SDWIS records document zero 3-year EPA health or monitoring rule violations on record; under UCMR 5 monitoring, UCMR 5 samples measured 8.3 ppt for PFOS (exceeding the 4.0 ppt federal rule), and 31.6% of homes across 1 served ZIP code predate 1980.

- **EPA PWSID** : CA2410008

- **Population Served** : 5,723

- **Water Source** : Groundwater

- **Max UCMR 5 PFAS** : 8.3 ppt (PFOS)

- **3-Yr Health Flags** : 0 Health Viol.

Water chemistry briefing — Cal Am - Meadowbrook

Because Cal Am - Meadowbrook relies on groundwater wells, dissolved limestone and mineral salts commonly elevate scale formation inside tankless coils and electric water heater elements; California's statewide USGS median is 36.1 GPG (Very Hard). UCMR 5 samples reached 8.3 ppt for PFOS (at or above EPA's 4.0 ppt enforceable MCL). Prioritize an under-sink NSF/ANSI 58 RO membrane or NSF 53 PFAS-certified block filter for drinking and cooking water.

Across 12,173 housing units in Cal Am - Meadowbrook's 1 ZIP code (median value $352,700), 31.6% predates 1980 (6.2% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

## How Clean and Hard Is Tap Water Supplied by Cal Am - Meadowbrook?

Examine Cal Am - Meadowbrook's raw source water category, historical SDWA violations, and pre-1980 neighborhood pipe exposure in Merced.

EPA SDWA and local housing profile for Cal Am - Meadowbrook (CA2410008)

| Water System Parameter | Measured / Reported Value | Benchmark / Federal Limit | Homeowner Impact |
|---|---|---|---|
| EPA Utility ID & Ownership | CA2410008 (Private) | Active CWS | Last sanitary visit: 04/08/2026 |
| Primary Source Water | Ground Water | GW vs. SW | Harder mineral load expected |
| Service Area & Population | 5,723 residents | #546 in California | Counties: Merced |
| Served ZIP Codes | 95348 | 1 ZIP code | Verify utility on local municipal water bill |
| Pre-1980 Housing Share | 31.6% (6.2% pre-1960) | 1986 Lead Ban | Mostly post-1980 copper or PEX piping |
| 3-Year EPA SDWA Compliance | 0 rule violations (0 qtrs) | Zero health flags target | No health-based compliance flags |
| State Tap Hardness Baseline | 36.1 GPG (Very Hard) | >= 7.0 GPG = Hard | Size ion-exchange resin on local grain test |

## Are Forever Chemicals Detected in Cal Am - Meadowbrook Distribution Lines?

Federal UCMR 5 screening tracks synthetic PFAS compounds across US community utilities; verify CA2410008's maximum detections compound by compound.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for CA2410008

| Regulated Compound / Screen | Max Detected | EPA Regulatory Standard | Compliance & Filtration Note |
|---|---|---|---|
| PFOA | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFOS | 8.3 ppt | 4.0 ppt EPA MCL | Exceeds EPA threshold — NSF 58 RO strongly advised |
| PFHxS | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFNA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| HFPO-DA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |

## Who Are the Closest California Community System Peers?

Compare four other California utilities of comparable population scale to benchmark source protection and treatment performance.

Nearby community water systems in California for side-by-side comparison

| Utility Name & PWSID | City / County | Population Served | Primary Source | Health Violations |
|---|---|---|---|---|
| [San Joaquin County - Lincoln Village](https://gcsradheat.com/water-quality/california/ca3910010-san-joaquin-county-lincoln-village/) (CA3910010) | San Joaquin | 5,841 | Surface / Mixed | 0 |
| [Rancho Murieta Community Servi](https://gcsradheat.com/water-quality/california/ca3410005-rancho-murieta-community-servi/) (CA3410005) | Sacramento | 5,728 | Surface / Mixed | 0 |
| [Pauma](https://gcsradheat.com/water-quality/california/090605012-pauma/) (090605012) | California | 5,700 | Groundwater | 0 |
| [La Habra Heights Cwd](https://gcsradheat.com/water-quality/california/ca1910218-la-habra-heights-cwd/) (CA1910218) | Los Angeles | 5,682 | Surface / Mixed | 0 |

## When Should Cal Am - Meadowbrook Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Merced; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

### Key Limitations & Exclusions

- Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
- Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
- Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

### Which Option Fits Your Situation?

**Pre-1980 Home or Young Family** Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.

**Installing a New Tankless Water Heater** Check tap hardness (36.1 GPG) and add scale inhibition on groundwater feeds.

## Drinking Water & Pipe Safety FAQs: CA2410008

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### How does Cal Am - Meadowbrook's supply type affect hardness and scale in home plumbing?

EPA ECHO classifies Cal Am - Meadowbrook (CA2410008) as a Ground Water community system serving 5,723 residents across Merced. Groundwater supplies draw from subsurface aquifers and typically carry higher dissolved calcium and magnesium carbonate, making annual tank flushing and scale protection important.

### Should Cal Am - Meadowbrook homeowners filter tap water for PFAS forever chemicals?

Yes—UCMR 5 laboratory testing for CA2410008 recorded 4 PFAS detections peaking at 8.3 ppt (PFOS), which sits at or above EPA's 4.0 ppt enforceable MCL. NSF/ANSI 58 reverse osmosis or NSF 53 PFAS-rated carbon effectively reduces exposure at the drinking tap.

### Does EPA's 10 ppb LCRI lead rule apply to houses on Cal Am - Meadowbrook?

Across the 1 ZIP codes served by Cal Am - Meadowbrook, approximately 31.6% of residential housing units were built before 1980 (6.2% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

## State Plumbing & Water Hardness Tools for California

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare San Joaquin County - Lincoln Village (CA3910010)→](https://gcsradheat.com/water-quality/california/ca3910010-san-joaquin-county-lincoln-village/)
- [Compare Rancho Murieta Community Servi (CA3410005)→](https://gcsradheat.com/water-quality/california/ca3410005-rancho-murieta-community-servi/)
- [Browse All California Community Water Utilities→](https://gcsradheat.com/water-quality/california/)
- [Inspect California County Well, Freeze & Pipe Data→](https://gcsradheat.com/counties/california/)
- [Check Well Water PFAS, Radon & Filtration Guide→](https://gcsradheat.com/guides/well-water-filtration-radon-pfas/)

## Sources

1. [EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download](https://echo.epa.gov/tools/data-downloads) — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
2. [Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State](https://www.epa.gov/dwucmr/occurrence-data-unregulated-contaminant-monitoring-rule) — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
3. [PFAS National Primary Drinking Water Regulation & LCRI Overview](https://www.epa.gov/sdwa/and-polyfluoroalkyl-substances-pfas) — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
4. [Lead and Copper Rule Improvements (LCRI) & Service Line Inventories](https://www.epa.gov/ground-water-and-drinking-water/lead-and-copper-rule-improvements) — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
5. [National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg)](https://www.waterqualitydata.us/data/Result/search) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
6. [U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File](https://www2.census.gov/programs-surveys/acs/summary_file/2023/table-based-SF/) — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Protection Priority

### Point-of-Use Reverse Osmosis (NSF/ANSI 58) or Catalytic Carbon (NSF 53)

EPA CA2410008 serves 5,723 people; match drinking tap filters and scale prevention to Merced water.
[All California Utilities](https://gcsradheat.com/water-quality/california/) [Check Softener Grain Sizing](https://gcsradheat.com/tools/water-softener-calculator/)
