title: "Golden State Wc - Placentia/Yorba Linda (CA3010035) Water"
url: https://gcsradheat.com/water-quality/california/ca3010035-golden-state-wc-placentia-yorba-linda/
description: "Golden State Wc - Placentia/Yorba Linda (CA3010035) is a Private public water utility serving 50,804 residents in Orange, California primarily from surface."
---

California water passport · EPA CA3010035

# Golden State Wc - Placentia/Yorba Linda Water Quality, PFAS & Utility Report (CA3010035)

Golden State Wc - Placentia/Yorba Linda (CA3010035) is a Private public water utility serving 50,804 residents in Orange, California primarily from surface water purchased. EPA ECHO logs show zero 3-year EPA health or monitoring rule violations on record, while UCMR 5 samples measured 6.5 ppt for PFOS (exceeding the 4.0 ppt federal rule). Roughly 59.5% of homes across 3 served ZIP codes predate 1980.

- **EPA PWSID** : CA3010035

- **Population Served** : 50,804

- **Water Source** : Surface Water

- **Max UCMR 5 PFAS** : 6.5 ppt (PFOS)

- **3-Yr Health Flags** : 0 Health Viol.

Filtration & pipe verdict for Golden State Wc - Placentia/Yorba Linda

Drawing surface water across Orange, Golden State Wc - Placentia/Yorba Linda uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. UCMR 5 samples reached 6.5 ppt for PFOS (at or above EPA's 4.0 ppt enforceable MCL). Prioritize an under-sink NSF/ANSI 58 RO membrane or NSF 53 PFAS-certified block filter for drinking and cooking water.

Across 48,154 housing units in Golden State Wc - Placentia/Yorba Linda's 3 ZIP codes (median value $950,400), 59.5% predates 1980 (5.6% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

## What Are Golden State Wc - Placentia/Yorba Linda's Source Water, Population, and Pipe Risk Metrics?

Audited below are the core EPA ECHO distribution metrics, served ZIP codes, and local housing-era indicators shaping plumbing longevity in Golden State Wc - Placentia/Yorba Linda's network.

EPA SDWA and local housing profile for Golden State Wc - Placentia/Yorba Linda (CA3010035)

| Water System Parameter | Measured / Reported Value | Benchmark / Federal Limit | Homeowner Impact |
|---|---|---|---|
| EPA Utility ID & Ownership | CA3010035 (Private) | Active CWS | Last sanitary visit: 10/19/2022 |
| Primary Source Water | Surface Water Purchased | GW vs. SW | Disinfection byproduct check recommended |
| Service Area & Population | 50,804 residents | #183 in California | Counties: Orange |
| Served ZIP Codes | 92807, 92870, 92886 | 3 ZIP codes | Verify utility on local municipal water bill |
| Pre-1980 Housing Share | 59.5% (5.6% pre-1960) | 1986 Lead Ban | Higher likelihood of legacy lead solder or galvanized laterals |
| 3-Year EPA SDWA Compliance | 0 rule violations (0 qtrs) | Zero health flags target | No health-based compliance flags |
| State Tap Hardness Baseline | 36.1 GPG (Very Hard) | >= 7.0 GPG = Hard | Size ion-exchange resin on local grain test |

## Did CA3010035 Detect PFAS Under EPA UCMR 5 Sampling?

Compare measured UCMR 5 laboratory results for Golden State Wc - Placentia/Yorba Linda against EPA's enforceable 4.0 ppt PFOA/PFOS limits and state Consumer Confidence reporting.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for CA3010035

| Regulated Compound / Screen | Max Detected | EPA Regulatory Standard | Compliance & Filtration Note |
|---|---|---|---|
| PFOA | 6.0 ppt | 4.0 ppt EPA MCL | Exceeds EPA threshold — NSF 58 RO strongly advised |
| PFOS | 6.5 ppt | 4.0 ppt EPA MCL | Exceeds EPA threshold — NSF 58 RO strongly advised |
| PFHxS | 3.6 ppt | 10 ppt EPA MCL | Detected below final EPA federal MCL |
| PFNA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| HFPO-DA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |

## How Does Golden State Wc - Placentia/Yorba Linda Compare to Peer California Utilities?

Review four nearby California community water utilities matched by service rank inside California's 669-utility public water catalog.

Nearby community water systems in California for side-by-side comparison

| Utility Name & PWSID | City / County | Population Served | Primary Source | Health Violations |
|---|---|---|---|---|
| [City Of San Clemente](https://gcsradheat.com/water-quality/california/ca3010036-city-of-san-clemente/) (CA3010036) | San Clemente | 51,545 | Surface / Mixed | 0 |
| [Delano, City Of](https://gcsradheat.com/water-quality/california/ca1510005-delano-city-of/) (CA1510005) | Delano | 51,428 | Groundwater | 0 |
| [Cal Am - Parkway](https://gcsradheat.com/water-quality/california/ca3410017-cal-am-parkway/) (CA3410017) | Sacramento | 50,646 | Surface / Mixed | 0 |
| [Gswc - Artesia](https://gcsradheat.com/water-quality/california/ca1910004-gswc-artesia/) (CA1910004) | Los Angeles | 50,415 | Groundwater | 0 |

## When Should Golden State Wc - Placentia/Yorba Linda Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Orange; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

### Key Limitations & Exclusions

- Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
- Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
- Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

### Which Option Fits Your Situation?

**Pre-1980 Home or Young Family** Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.

**Installing a New Tankless Water Heater** Check tap hardness (36.1 GPG) and add scale inhibition on groundwater feeds.

## Homeowner Water Quality FAQs for Golden State Wc - Placentia/Yorba Linda (CA3010035)

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Where does Golden State Wc - Placentia/Yorba Linda (CA3010035) source drinking water?

EPA ECHO classifies Golden State Wc - Placentia/Yorba Linda (CA3010035) as a Surface Water Purchased community system serving 50,804 residents across Orange. Surface supplies pull from rivers, lakes, or reservoirs and require chlorine or chloramine disinfection plus monitoring for disinfection byproducts.

### Were PFAS compounds detected in Golden State Wc - Placentia/Yorba Linda UCMR 5 testing?

Yes—UCMR 5 laboratory testing for CA3010035 recorded 7 PFAS detections peaking at 6.5 ppt (PFOS), which sits at or above EPA's 4.0 ppt enforceable MCL. NSF/ANSI 58 reverse osmosis or NSF 53 PFAS-rated carbon effectively reduces exposure at the drinking tap.

### Could homes served by Golden State Wc - Placentia/Yorba Linda still face lead solder or older pipe risks?

Across the 3 ZIP codes served by Golden State Wc - Placentia/Yorba Linda, approximately 59.5% of residential housing units were built before 1980 (5.6% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

## Next Water Quality & State Guides for Orange

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare City Of San Clemente (CA3010036)→](https://gcsradheat.com/water-quality/california/ca3010036-city-of-san-clemente/)
- [Compare Delano, City Of (CA1510005)→](https://gcsradheat.com/water-quality/california/ca1510005-delano-city-of/)
- [Browse All California Community Water Utilities→](https://gcsradheat.com/water-quality/california/)
- [Inspect California County Well, Freeze & Pipe Data→](https://gcsradheat.com/counties/california/)
- [Check Well Water PFAS, Radon & Filtration Guide→](https://gcsradheat.com/guides/well-water-filtration-radon-pfas/)

## Sources

1. [EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download](https://echo.epa.gov/tools/data-downloads) — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
2. [Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State](https://www.epa.gov/dwucmr/occurrence-data-unregulated-contaminant-monitoring-rule) — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
3. [PFAS National Primary Drinking Water Regulation & LCRI Overview](https://www.epa.gov/sdwa/and-polyfluoroalkyl-substances-pfas) — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
4. [Lead and Copper Rule Improvements (LCRI) & Service Line Inventories](https://www.epa.gov/ground-water-and-drinking-water/lead-and-copper-rule-improvements) — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
5. [National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg)](https://www.waterqualitydata.us/data/Result/search) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
6. [U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File](https://www2.census.gov/programs-surveys/acs/summary_file/2023/table-based-SF/) — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Recommended for CA3010035

### Point-of-Use Reverse Osmosis (NSF/ANSI 58) or Catalytic Carbon (NSF 53)

Match filters to surface water chemistry in Orange, CA. State hardness baseline: 36.1 GPG.
[All California Utilities](https://gcsradheat.com/water-quality/california/) [Check Softener Grain Sizing](https://gcsradheat.com/tools/water-softener-calculator/)