# Cal Am - Suburban Rosemont Water Quality, PFAS & Utility Report (CA3410010)

Ranked #174 of 669 major community water utilities in California, Cal Am - Suburban Rosemont (CA3410010) delivers surface water purchased to 54,893 people around Sacramento. Public records indicate zero 3-year EPA health or monitoring rule violations on record and note that UCMR 5 samples measured 13.4 ppt for PFOS (exceeding the 4.0 ppt federal rule). Recommended home check: Install NSF 58 RO + whole-house pre-filter.

- **EPA PWSID** : CA3410010

- **Population Served** : 54,893

- **Water Source** : Surface Water

- **Max UCMR 5 PFAS** : 13.4 ppt (PFOS)

- **3-Yr Health Flags** : 0 Health Viol.

Homeowner takeaway for CA3410010

Drawing surface water across Sacramento, Cal Am - Suburban Rosemont uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. UCMR 5 samples reached 13.4 ppt for PFOS (at or above EPA's 4.0 ppt enforceable MCL). Prioritize an under-sink NSF/ANSI 58 RO membrane or NSF 53 PFAS-certified block filter for drinking and cooking water.

Across 85,771 housing units in Cal Am - Suburban Rosemont's 6 ZIP codes (median value $508,833), 58.0% predates 1980 (12.6% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

## Which Compliance and Housing Indicators Define CA3410010?

These verified utility measurements pair EPA SDWIS facility data for Cal Am - Suburban Rosemont with Census housing vintage across its 6 served ZIP codes.

EPA SDWA and local housing profile for Cal Am - Suburban Rosemont (CA3410010)

| Water System Parameter | Measured / Reported Value | Benchmark / Federal Limit | Homeowner Impact |
|---|---|---|---|
| EPA Utility ID & Ownership | CA3410010 (Private) | Active CWS | Last sanitary visit: 10/29/2024 |
| Primary Source Water | Surface Water Purchased | GW vs. SW | Disinfection byproduct check recommended |
| Service Area & Population | 54,893 residents | #174 in California | Counties: Sacramento |
| Served ZIP Codes | 95608, 95655, 95670, 95826, 95827, 95829 | 6 ZIP codes | Verify utility on local municipal water bill |
| Pre-1980 Housing Share | 58.0% (12.6% pre-1960) | 1986 Lead Ban | Higher likelihood of legacy lead solder or galvanized laterals |
| 3-Year EPA SDWA Compliance | 0 rule violations (0 qtrs) | Zero health flags target | No health-based compliance flags |
| State Tap Hardness Baseline | 36.1 GPG (Very Hard) | >= 7.0 GPG = Hard | Size ion-exchange resin on local grain test |

## How Do Cal Am - Suburban Rosemont PFAS Levels Stack Up Against 4.0 ppt Rules?

EPA's National Primary Drinking Water Regulation sets strict 4.0 ppt limits on PFOA and PFOS; inspect Cal Am - Suburban Rosemont's monitored results below.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for CA3410010

| Regulated Compound / Screen | Max Detected | EPA Regulatory Standard | Compliance & Filtration Note |
|---|---|---|---|
| PFOA | 8.2 ppt | 4.0 ppt EPA MCL | Exceeds EPA threshold — NSF 58 RO strongly advised |
| PFOS | 13.4 ppt | 4.0 ppt EPA MCL | Exceeds EPA threshold — NSF 58 RO strongly advised |
| PFHxS | 10.9 ppt | 10 ppt EPA MCL | Exceeds EPA threshold — NSF 58 RO strongly advised |
| PFNA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| HFPO-DA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |

## What Do Neighboring Community Water Systems Report in California?

Cross-check four peer California water utilities to see how Cal Am - Suburban Rosemont ranks by system size, groundwater reliance, and EPA notices.

Nearby community water systems in California for side-by-side comparison

| Utility Name & PWSID | City / County | Population Served | Primary Source | Health Violations |
|---|---|---|---|---|
| [Paramount - City, Water Dept.](https://gcsradheat.com/water-quality/california/ca1910105-paramount-city-water-dept/) (CA1910105) | Paramount | 55,200 | Surface / Mixed | 0 |
| [Gswc - Bell, Bell Gardens](https://gcsradheat.com/water-quality/california/ca1910011-gswc-bell-bell-gardens/) (CA1910011) | Los Angeles | 55,050 | Surface / Mixed | 0 |
| [City Of Thousand Oaks Water Department](https://gcsradheat.com/water-quality/california/ca5610020-city-of-thousand-oaks-water-department/) (CA5610020) | Ventura | 54,770 | Surface / Mixed | 0 |
| [Ceres, City Of](https://gcsradheat.com/water-quality/california/ca5010028-ceres-city-of/) (CA5010028) | Ceres | 54,513 | Surface / Mixed | 1 |

## When Should Cal Am - Suburban Rosemont Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Sacramento; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

### Key Limitations & Exclusions

- Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
- Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
- Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

### Which Option Fits Your Situation?

**Pre-1980 Home or Young Family** Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.

**Installing a New Tankless Water Heater** Check tap hardness (36.1 GPG) and add scale inhibition on groundwater feeds.

## Key Questions About Tap Water From Cal Am - Suburban Rosemont

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### What water source serves the 54,893 customers under EPA ID CA3410010?

EPA ECHO classifies Cal Am - Suburban Rosemont (CA3410010) as a Surface Water Purchased community system serving 54,893 residents across Sacramento. Surface supplies pull from rivers, lakes, or reservoirs and require chlorine or chloramine disinfection plus monitoring for disinfection byproducts.

### How do Cal Am - Suburban Rosemont PFAS levels compare to EPA's 4.0 ppt federal limit?

Yes—UCMR 5 laboratory testing for CA3410010 recorded 12 PFAS detections peaking at 13.4 ppt (PFOS), which sits at or above EPA's 4.0 ppt enforceable MCL. NSF/ANSI 58 reverse osmosis or NSF 53 PFAS-rated carbon effectively reduces exposure at the drinking tap.

### What pipe materials should homeowners served by Cal Am - Suburban Rosemont inspect?

Across the 6 ZIP codes served by Cal Am - Suburban Rosemont, approximately 58.0% of residential housing units were built before 1980 (12.6% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

## Additional Water Softener & Code Tools for CA

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Paramount - City, Water Dept. (CA1910105)→](https://gcsradheat.com/water-quality/california/ca1910105-paramount-city-water-dept/)
- [Compare Gswc - Bell, Bell Gardens (CA1910011)→](https://gcsradheat.com/water-quality/california/ca1910011-gswc-bell-bell-gardens/)
- [Browse All California Community Water Utilities→](https://gcsradheat.com/water-quality/california/)
- [Inspect California County Well, Freeze & Pipe Data→](https://gcsradheat.com/counties/california/)
- [Check Well Water PFAS, Radon & Filtration Guide→](https://gcsradheat.com/guides/well-water-filtration-radon-pfas/)

## Sources

1. [EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download](https://echo.epa.gov/tools/data-downloads) — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
2. [Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State](https://www.epa.gov/dwucmr/occurrence-data-unregulated-contaminant-monitoring-rule) — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
3. [PFAS National Primary Drinking Water Regulation & LCRI Overview](https://www.epa.gov/sdwa/and-polyfluoroalkyl-substances-pfas) — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
4. [Lead and Copper Rule Improvements (LCRI) & Service Line Inventories](https://www.epa.gov/ground-water-and-drinking-water/lead-and-copper-rule-improvements) — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
5. [National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg)](https://www.waterqualitydata.us/data/Result/search) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
6. [U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File](https://www2.census.gov/programs-surveys/acs/summary_file/2023/table-based-SF/) — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Filter Spec (CA)

### Point-of-Use Reverse Osmosis (NSF/ANSI 58) or Catalytic Carbon (NSF 53)

Serving Sacramento via surface water; confirm cartridge micron & NSF 53/58 certifications locally.
[All California Utilities](https://gcsradheat.com/water-quality/california/) [Check Softener Grain Sizing](https://gcsradheat.com/tools/water-softener-calculator/)