---
title: "Atascadero State Hospital (CA4010832) Water Quality & PFAS"
url: https://gcsradheat.com/water-quality/california/ca4010832-atascadero-state-hospital/
description: "Supplying 1,100 customers across San Luis Obispo, California, Atascadero State Hospital (EPA ID CA4010832) relies on ground water for daily municipal flow."
---

Utility quality file · San Luis Obispo, CA (CA4010832)

# Atascadero State Hospital Water Quality, PFAS & Utility Report (CA4010832)

Supplying 1,100 customers across San Luis Obispo, California, Atascadero State Hospital (EPA ID CA4010832) relies on ground water for daily municipal flow. Current federal compliance files record zero EPA health violations alongside 1 monitoring/reporting notice; meanwhile UCMR 5 samples measured 34.0 ppt for PFHxS (exceeding the 4.0 ppt federal rule), and check building year in San Luis Obispo for pre-1986 lead solder risk.

- **EPA PWSID** : CA4010832

- **Population Served** : 1,100

- **Water Source** : Groundwater

- **Max UCMR 5 PFAS** : 34.0 ppt (PFHxS)

- **3-Yr Health Flags** : 0 Health Viol.

Tap treatment summary — CA4010832

Because Atascadero State Hospital relies on groundwater wells, dissolved limestone and mineral salts commonly elevate scale formation inside tankless coils and electric water heater elements; California's statewide USGS median is 36.1 GPG (Very Hard). UCMR 5 samples reached 34.0 ppt for PFHxS (at or above EPA's 4.0 ppt enforceable MCL). Prioritize an under-sink NSF/ANSI 58 RO membrane or NSF 53 PFAS-certified block filter for drinking and cooking water.

Even when Atascadero State Hospital passes distribution sampling, interior plumbing installed before June 1986 can contribute brass or lead solder leachate after overnight stagnation—flushing cold kitchen lines for 30–60 seconds cuts first-draw spikes.

## How Is Atascadero State Hospital's Municipal Water Supplied and Regulated?

Review Atascadero State Hospital's supply classification, customer headcount, local pre-1980 housing density, and 3-year Safe Drinking Water Act inspection metrics below.

EPA SDWA and local housing profile for Atascadero State Hospital (CA4010832)

| Water System Parameter | Measured / Reported Value | Benchmark / Federal Limit | Homeowner Impact |
|---|---|---|---|
| EPA Utility ID & Ownership | CA4010832 (State Or Territorial Government) | Active CWS | Last sanitary visit: 05/06/2026 |
| Primary Source Water | Ground Water | GW vs. SW | Harder mineral load expected |
| Service Area & Population | 1,100 residents | #664 in California | Counties: San Luis Obispo |
| Served ZIP Codes | 93423 | 1 ZIP code | Verify utility on local municipal water bill |
| Pre-1980 Housing Share | Check municipal permit date | 1986 Lead Ban | Mostly post-1980 copper or PEX piping |
| 3-Year EPA SDWA Compliance | 1 rule violation (2 qtrs) | Zero health flags target | 1040=Nitrate |
| State Tap Hardness Baseline | 36.1 GPG (Very Hard) | >= 7.0 GPG = Hard | Size ion-exchange resin on local grain test |

## What Do Federal PFAS Lab Results Show for Atascadero State Hospital?

See how Atascadero State Hospital (CA4010832) performed across federal UCMR 5 compounds alongside EPA's 4.0 ppt enforcement standard for PFOA and PFOS.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for CA4010832

| Regulated Compound / Screen | Max Detected | EPA Regulatory Standard | Compliance & Filtration Note |
|---|---|---|---|
| PFOA | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFOS | 33.0 ppt | 4.0 ppt EPA MCL | Exceeds EPA threshold — NSF 58 RO strongly advised |
| PFHxS | 34.0 ppt | 10 ppt EPA MCL | Exceeds EPA threshold — NSF 58 RO strongly advised |
| PFNA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| HFPO-DA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| Lead / Copper 90th Pct | Pb: — / Cu: 4 | 10 ppb Lead (LCRI) / 1.3 ppm Cu | Utility distribution sample |

## Which Nearby California Water Utilities Match This Profile?

Compare population scale, water source, and compliance status across four comparable community systems operating in California.

Nearby community water systems in California for side-by-side comparison

| Utility Name & PWSID | City / County | Population Served | Primary Source | Health Violations |
|---|---|---|---|---|
| [Sea Ranch Water Company,The (Puc)](https://gcsradheat.com/water-quality/california/ca4910007-sea-ranch-water-company-the-puc/) (CA4910007) | Sonoma | 1,287 | Surface / Mixed | 3 |
| [Laton Community Services District](https://gcsradheat.com/water-quality/california/ca1010020-laton-community-services-district/) (CA1010020) | Fresno | 1,151 | Groundwater | 1 |
| [California Rehabilitation Center - Norco](https://gcsradheat.com/water-quality/california/ca3310800-california-rehabilitation-center-norco/) (CA3310800) | Riverside | 750 | Surface / Mixed | 0 |
| [Loma Linda University](https://gcsradheat.com/water-quality/california/ca3600152-loma-linda-university/) (CA3600152) | San Bernardino | 455 | Groundwater | 0 |

## When Should Atascadero State Hospital Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in San Luis Obispo; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

### Key Limitations & Exclusions

- Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
- Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
- Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

### Which Option Fits Your Situation?

**Pre-1980 Home or Young Family** Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.

**Installing a New Tankless Water Heater** Check tap hardness (36.1 GPG) and add scale inhibition on groundwater feeds.

## Practical Drinking Water Questions for San Luis Obispo Residents

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Does Atascadero State Hospital draw from groundwater aquifers or surface water reservoirs?

EPA ECHO classifies Atascadero State Hospital (CA4010832) as a Ground Water community system serving 1,100 residents across San Luis Obispo. Groundwater supplies draw from subsurface aquifers and typically carry higher dissolved calcium and magnesium carbonate, making annual tank flushing and scale protection important.

### What did federal UCMR 5 sampling measure in CA4010832?

Yes—UCMR 5 laboratory testing for CA4010832 recorded 6 PFAS detections peaking at 34.0 ppt (PFHxS), which sits at or above EPA's 4.0 ppt enforceable MCL. NSF/ANSI 58 reverse osmosis or NSF 53 PFAS-rated carbon effectively reduces exposure at the drinking tap.

### How does local home age affect plumbing risk inside CA4010832's service area?

Even when Atascadero State Hospital meets utility-side distribution targets under EPA's 10 ppb Lead and Copper Rule Improvements (LCRI), homes built before 1986 can release lead from private interior solder, brass valves, or aging galvanized laterals.

## Related California Pipe & Softener Links

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Sea Ranch Water Company,The (Puc) (CA4910007)→](https://gcsradheat.com/water-quality/california/ca4910007-sea-ranch-water-company-the-puc/)
- [Compare Laton Community Services District (CA1010020)→](https://gcsradheat.com/water-quality/california/ca1010020-laton-community-services-district/)
- [Browse All California Community Water Utilities→](https://gcsradheat.com/water-quality/california/)
- [Inspect California County Well, Freeze & Pipe Data→](https://gcsradheat.com/counties/california/)
- [Check Well Water PFAS, Radon & Filtration Guide→](https://gcsradheat.com/guides/well-water-filtration-radon-pfas/)

## Sources

1. [EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download](https://echo.epa.gov/tools/data-downloads) — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
2. [Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State](https://www.epa.gov/dwucmr/occurrence-data-unregulated-contaminant-monitoring-rule) — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
3. [PFAS National Primary Drinking Water Regulation & LCRI Overview](https://www.epa.gov/sdwa/and-polyfluoroalkyl-substances-pfas) — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
4. [Lead and Copper Rule Improvements (LCRI) & Service Line Inventories](https://www.epa.gov/ground-water-and-drinking-water/lead-and-copper-rule-improvements) — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
5. [National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg)](https://www.waterqualitydata.us/data/Result/search) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
6. [U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File](https://www2.census.gov/programs-surveys/acs/summary_file/2023/table-based-SF/) — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

San Luis Obispo Tap Action

### Point-of-Use Reverse Osmosis (NSF/ANSI 58) or Catalytic Carbon (NSF 53)

For 1,100 customers on groundwater, focus on install nsf 58 ro + whole-house pre-filter before upgrading heaters.
[All California Utilities](https://gcsradheat.com/water-quality/california/) [Check Softener Grain Sizing](https://gcsradheat.com/tools/water-softener-calculator/)
