---
title: "Todd Creek Village Md (CO0101157) Water Quality & PFAS"
url: https://gcsradheat.com/water-quality/colorado/co0101157-todd-creek-village-md/
description: "Supplying 7,363 customers across Adams, Colorado, Todd Creek Village Md (EPA ID CO0101157) relies on groundwater under influence of surface water for daily."
---

Utility quality file · Adams, CO (CO0101157)

# Todd Creek Village Md Water Quality, PFAS & Utility Report (CO0101157)

Supplying 7,363 customers across Adams, Colorado, Todd Creek Village Md (EPA ID CO0101157) relies on groundwater under influence of surface water for daily municipal flow. Current federal compliance files record zero 3-year EPA health or monitoring rule violations on record; meanwhile UCMR 5 samples measured 38.0 ppt for PFBS (exceeding the 4.0 ppt federal rule), and 7.4% of homes across 2 served ZIP codes predate 1980.

- **EPA PWSID** : CO0101157

- **Population Served** : 7,363

- **Water Source** : Surface Water

- **Max UCMR 5 PFAS** : 38.0 ppt (PFBS)

- **3-Yr Health Flags** : 0 Health Viol.

Tap treatment summary — CO0101157

Drawing surface water across Adams, Todd Creek Village Md uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. UCMR 5 samples reached 38.0 ppt for PFBS (at or above EPA's 4.0 ppt enforceable MCL). Prioritize an under-sink NSF/ANSI 58 RO membrane or NSF 53 PFAS-certified block filter for drinking and cooking water.

Across 19,676 housing units in Todd Creek Village Md's 2 ZIP codes (median value $544,000), 7.4% predates 1980 (1.8% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

## How Is Todd Creek Village Md's Municipal Water Supplied and Regulated?

Review Todd Creek Village Md's supply classification, customer headcount, local pre-1980 housing density, and 3-year Safe Drinking Water Act inspection metrics below.

EPA SDWA and local housing profile for Todd Creek Village Md (CO0101157)

| Water System Parameter | Measured / Reported Value | Benchmark / Federal Limit | Homeowner Impact |
|---|---|---|---|
| EPA Utility ID & Ownership | CO0101157 (Private) | Active CWS | Last sanitary visit: 06/23/2023 |
| Primary Source Water | Groundwater Under Influence Of Surface Water | GW vs. SW | Disinfection byproduct check recommended |
| Service Area & Population | 7,363 residents | #124 in Colorado | Counties: Adams |
| Served ZIP Codes | 80602, 80603 | 2 ZIP codes | Verify utility on local municipal water bill |
| Pre-1980 Housing Share | 7.4% (1.8% pre-1960) | 1986 Lead Ban | Mostly post-1980 copper or PEX piping |
| 3-Year EPA SDWA Compliance | 0 rule violations (0 qtrs) | Zero health flags target | No health-based compliance flags |
| State Tap Hardness Baseline | 9.6 GPG (Hard) | >= 7.0 GPG = Hard | Size ion-exchange resin on local grain test |

## What Do Federal PFAS Lab Results Show for Todd Creek Village Md?

See how Todd Creek Village Md (CO0101157) performed across federal UCMR 5 compounds alongside EPA's 4.0 ppt enforcement standard for PFOA and PFOS.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for CO0101157

| Regulated Compound / Screen | Max Detected | EPA Regulatory Standard | Compliance & Filtration Note |
|---|---|---|---|
| PFOA | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFOS | 6.8 ppt | 4.0 ppt EPA MCL | Exceeds EPA threshold — NSF 58 RO strongly advised |
| PFHxS | 5.7 ppt | 10 ppt EPA MCL | Detected below final EPA federal MCL |
| PFNA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| HFPO-DA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |

## Which Nearby Colorado Water Utilities Match This Profile?

Compare population scale, water source, and compliance status across four comparable community systems operating in Colorado.

Nearby community water systems in Colorado for side-by-side comparison

| Utility Name & PWSID | City / County | Population Served | Primary Source | Health Violations |
|---|---|---|---|---|
| [Parkville Wd](https://gcsradheat.com/water-quality/colorado/co0133700-parkville-wd/) (CO0133700) | Lake | 7,500 | Surface / Mixed | 0 |
| [Lamar City Of](https://gcsradheat.com/water-quality/colorado/co0150700-lamar-city-of/) (CO0150700) | Prowers | 7,500 | Groundwater | 0 |
| [Eaton Town Of](https://gcsradheat.com/water-quality/colorado/co0162233-eaton-town-of/) (CO0162233) | Weld | 7,328 | Surface / Mixed | 0 |
| [Manitou Springs City Of](https://gcsradheat.com/water-quality/colorado/co0121450-manitou-springs-city-of/) (CO0121450) | El Paso | 6,938 | Surface / Mixed | 0 |

## When Should Todd Creek Village Md Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Adams; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

### Key Limitations & Exclusions

- Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
- Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
- Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

### Which Option Fits Your Situation?

**Pre-1980 Home or Young Family** Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.

**Installing a New Tankless Water Heater** Check tap hardness (9.6 GPG) and add scale inhibition on groundwater feeds.

## Practical Drinking Water Questions for Adams Residents

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Does Todd Creek Village Md draw from groundwater aquifers or surface water reservoirs?

EPA ECHO classifies Todd Creek Village Md (CO0101157) as a Groundwater Under Influence Of Surface Water community system serving 7,363 residents across Adams. Surface supplies pull from rivers, lakes, or reservoirs and require chlorine or chloramine disinfection plus monitoring for disinfection byproducts.

### What did federal UCMR 5 sampling measure in CO0101157?

Yes—UCMR 5 laboratory testing for CO0101157 recorded 12 PFAS detections peaking at 38.0 ppt (PFBS), which sits at or above EPA's 4.0 ppt enforceable MCL. NSF/ANSI 58 reverse osmosis or NSF 53 PFAS-rated carbon effectively reduces exposure at the drinking tap.

### How does local home age affect plumbing risk inside CO0101157's service area?

Across the 2 ZIP codes served by Todd Creek Village Md, approximately 7.4% of residential housing units were built before 1980 (1.8% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

## Related Colorado Pipe & Softener Links

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Parkville Wd (CO0133700)→](https://gcsradheat.com/water-quality/colorado/co0133700-parkville-wd/)
- [Compare Lamar City Of (CO0150700)→](https://gcsradheat.com/water-quality/colorado/co0150700-lamar-city-of/)
- [Browse All Colorado Community Water Utilities→](https://gcsradheat.com/water-quality/colorado/)
- [Inspect Colorado County Well, Freeze & Pipe Data→](https://gcsradheat.com/counties/colorado/)
- [Check Well Water PFAS, Radon & Filtration Guide→](https://gcsradheat.com/guides/well-water-filtration-radon-pfas/)

## Sources

1. [EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download](https://echo.epa.gov/tools/data-downloads) — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
2. [Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State](https://www.epa.gov/dwucmr/occurrence-data-unregulated-contaminant-monitoring-rule) — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
3. [PFAS National Primary Drinking Water Regulation & LCRI Overview](https://www.epa.gov/sdwa/and-polyfluoroalkyl-substances-pfas) — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
4. [Lead and Copper Rule Improvements (LCRI) & Service Line Inventories](https://www.epa.gov/ground-water-and-drinking-water/lead-and-copper-rule-improvements) — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
5. [National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg)](https://www.waterqualitydata.us/data/Result/search) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
6. [U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File](https://www2.census.gov/programs-surveys/acs/summary_file/2023/table-based-SF/) — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Adams Tap Action

### Point-of-Use Reverse Osmosis (NSF/ANSI 58) or Catalytic Carbon (NSF 53)

For 7,363 customers on surface water, focus on install nsf 58 ro + whole-house pre-filter before upgrading heaters.
[All Colorado Utilities](https://gcsradheat.com/water-quality/colorado/) [Check Softener Grain Sizing](https://gcsradheat.com/tools/water-softener-calculator/)
