title: "Parker Wsd (CO0118040) Water Quality & PFAS"
url: https://gcsradheat.com/water-quality/colorado/co0118040-parker-wsd/
description: "Parker Wsd (CO0118040) is a Local Government public water utility serving 75,949 residents in Douglas, Colorado primarily from surface water. EPA ECHO logs."
---

Colorado water passport · EPA CO0118040

# Parker Wsd Water Quality, PFAS & Utility Report (CO0118040)

Parker Wsd (CO0118040) is a Local Government public water utility serving 75,949 residents in Douglas, Colorado primarily from surface water. EPA ECHO logs show zero EPA health violations alongside 4 monitoring/reporting notices, while UCMR 5 samples measured 4.8 ppt for PFOA (exceeding the 4.0 ppt federal rule). Roughly 12.1% of homes across 5 served ZIP codes predate 1980.

- **EPA PWSID** : CO0118040

- **Population Served** : 75,949

- **Water Source** : Surface Water

- **Max UCMR 5 PFAS** : 4.8 ppt (PFOA)

- **3-Yr Health Flags** : 0 Health Viol.

Filtration & pipe verdict for Parker Wsd

Drawing surface water across Douglas, Parker Wsd uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. UCMR 5 samples reached 4.8 ppt for PFOA (at or above EPA's 4.0 ppt enforceable MCL). Prioritize an under-sink NSF/ANSI 58 RO membrane or NSF 53 PFAS-certified block filter for drinking and cooking water.

Across 81,257 housing units in Parker Wsd's 5 ZIP codes (median value $698,120), 12.1% predates 1980 (0.8% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

## What Are Parker Wsd's Source Water, Population, and Pipe Risk Metrics?

Audited below are the core EPA ECHO distribution metrics, served ZIP codes, and local housing-era indicators shaping plumbing longevity in Parker Wsd's network.

EPA SDWA and local housing profile for Parker Wsd (CO0118040)

| Water System Parameter | Measured / Reported Value | Benchmark / Federal Limit | Homeowner Impact |
|---|---|---|---|
| EPA Utility ID & Ownership | CO0118040 (Local Government) | Active CWS | Last sanitary visit: 08/07/2025 |
| Primary Source Water | Surface Water | GW vs. SW | Disinfection byproduct check recommended |
| Service Area & Population | 75,949 residents | #18 in Colorado | Counties: Douglas |
| Served ZIP Codes | 80108, 80112, 80124, 80134, 80138 | 5 ZIP codes | Verify utility on local municipal water bill |
| Pre-1980 Housing Share | 12.1% (0.8% pre-1960) | 1986 Lead Ban | Mostly post-1980 copper or PEX piping |
| 3-Year EPA SDWA Compliance | 4 rule violations (5 qtrs) | Zero health flags target | 0200=Surface Water Treatment Rule, 1008=Chlorine Dioxide, 1009=Chlorite, 3014=E. Coli |
| State Tap Hardness Baseline | 9.6 GPG (Hard) | >= 7.0 GPG = Hard | Size ion-exchange resin on local grain test |

## Did CO0118040 Detect PFAS Under EPA UCMR 5 Sampling?

Compare measured UCMR 5 laboratory results for Parker Wsd against EPA's enforceable 4.0 ppt PFOA/PFOS limits and state Consumer Confidence reporting.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for CO0118040

| Regulated Compound / Screen | Max Detected | EPA Regulatory Standard | Compliance & Filtration Note |
|---|---|---|---|
| PFOA | 4.8 ppt | 4.0 ppt EPA MCL | Exceeds EPA threshold — NSF 58 RO strongly advised |
| PFOS | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFHxS | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFNA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| HFPO-DA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |

## How Does Parker Wsd Compare to Peer Colorado Utilities?

Review four nearby Colorado community water utilities matched by service rank inside Colorado's 175-utility public water catalog.

Nearby community water systems in Colorado for side-by-side comparison

| Utility Name & PWSID | City / County | Population Served | Primary Source | Health Violations |
|---|---|---|---|---|
| [Loveland City Of](https://gcsradheat.com/water-quality/colorado/co0135485-loveland-city-of/) (CO0135485) | Larimer | 91,077 | Surface / Mixed | 0 |
| [Consolidated Mutual Maple Grove](https://gcsradheat.com/water-quality/colorado/co0130020-consolidated-mutual-maple-grove/) (CO0130020) | Jefferson | 81,400 | Surface / Mixed | 0 |
| [South Adams County Wsd](https://gcsradheat.com/water-quality/colorado/co0101140-south-adams-county-wsd/) (CO0101140) | Adams | 75,559 | Surface / Mixed | 0 |
| [East Cherry Creek Valley Wsd](https://gcsradheat.com/water-quality/colorado/co0103035-east-cherry-creek-valley-wsd/) (CO0103035) | Arapahoe | 66,130 | Surface / Mixed | 0 |

## When Should Parker Wsd Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Douglas; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

### Key Limitations & Exclusions

- Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
- Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
- Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

### Which Option Fits Your Situation?

**Pre-1980 Home or Young Family** Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.

**Installing a New Tankless Water Heater** Check tap hardness (9.6 GPG) and add scale inhibition on groundwater feeds.

## Homeowner Water Quality FAQs for Parker Wsd (CO0118040)

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Where does Parker Wsd (CO0118040) source drinking water?

EPA ECHO classifies Parker Wsd (CO0118040) as a Surface Water community system serving 75,949 residents across Douglas. Surface supplies pull from rivers, lakes, or reservoirs and require chlorine or chloramine disinfection plus monitoring for disinfection byproducts.

### Were PFAS compounds detected in Parker Wsd UCMR 5 testing?

Yes—UCMR 5 laboratory testing for CO0118040 recorded 7 PFAS detections peaking at 4.8 ppt (PFOA), which sits at or above EPA's 4.0 ppt enforceable MCL. NSF/ANSI 58 reverse osmosis or NSF 53 PFAS-rated carbon effectively reduces exposure at the drinking tap.

### Could homes served by Parker Wsd still face lead solder or older pipe risks?

Across the 5 ZIP codes served by Parker Wsd, approximately 12.1% of residential housing units were built before 1980 (0.8% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

## Next Water Quality & State Guides for Douglas

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Loveland City Of (CO0135485)→](https://gcsradheat.com/water-quality/colorado/co0135485-loveland-city-of/)
- [Compare Consolidated Mutual Maple Grove (CO0130020)→](https://gcsradheat.com/water-quality/colorado/co0130020-consolidated-mutual-maple-grove/)
- [Browse All Colorado Community Water Utilities→](https://gcsradheat.com/water-quality/colorado/)
- [Inspect Colorado County Well, Freeze & Pipe Data→](https://gcsradheat.com/counties/colorado/)
- [Check Well Water PFAS, Radon & Filtration Guide→](https://gcsradheat.com/guides/well-water-filtration-radon-pfas/)

## Sources

1. [EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download](https://echo.epa.gov/tools/data-downloads) — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
2. [Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State](https://www.epa.gov/dwucmr/occurrence-data-unregulated-contaminant-monitoring-rule) — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
3. [PFAS National Primary Drinking Water Regulation & LCRI Overview](https://www.epa.gov/sdwa/and-polyfluoroalkyl-substances-pfas) — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
4. [Lead and Copper Rule Improvements (LCRI) & Service Line Inventories](https://www.epa.gov/ground-water-and-drinking-water/lead-and-copper-rule-improvements) — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
5. [National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg)](https://www.waterqualitydata.us/data/Result/search) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
6. [U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File](https://www2.census.gov/programs-surveys/acs/summary_file/2023/table-based-SF/) — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Recommended for CO0118040

### Point-of-Use Reverse Osmosis (NSF/ANSI 58) or Catalytic Carbon (NSF 53)

Match filters to surface water chemistry in Douglas, CO. State hardness baseline: 9.6 GPG.
[All Colorado Utilities](https://gcsradheat.com/water-quality/colorado/) [Check Softener Grain Sizing](https://gcsradheat.com/tools/water-softener-calculator/)