---
title: "Rocky Ford City Of (CO0145600) Water Quality & PFAS"
url: https://gcsradheat.com/water-quality/colorado/co0145600-rocky-ford-city-of/
description: "Supplying 4,443 customers across Otero, Colorado, Rocky Ford City Of (EPA ID CO0145600) relies on ground water for daily municipal flow. Current federal."
---

Utility quality file · Otero, CO (CO0145600)

# Rocky Ford City Of Water Quality, PFAS & Utility Report (CO0145600)

Supplying 4,443 customers across Otero, Colorado, Rocky Ford City Of (EPA ID CO0145600) relies on ground water for daily municipal flow. Current federal compliance files record zero EPA health violations alongside 1 monitoring/reporting notice; meanwhile UCMR 5 samples measured 8.5 ppt for PFBS (exceeding the 4.0 ppt federal rule), and 77.3% of homes across 1 served ZIP code predate 1980.

- **EPA PWSID** : CO0145600

- **Population Served** : 4,443

- **Water Source** : Groundwater

- **Max UCMR 5 PFAS** : 8.5 ppt (PFBS)

- **3-Yr Health Flags** : 0 Health Viol.

Tap treatment summary — CO0145600

Because Rocky Ford City Of relies on groundwater wells, dissolved limestone and mineral salts commonly elevate scale formation inside tankless coils and electric water heater elements; Colorado's statewide USGS median is 9.6 GPG (Hard). UCMR 5 samples reached 8.5 ppt for PFBS (at or above EPA's 4.0 ppt enforceable MCL). Prioritize an under-sink NSF/ANSI 58 RO membrane or NSF 53 PFAS-certified block filter for drinking and cooking water.

Across 2,419 housing units in Rocky Ford City Of's 1 ZIP code (median value $139,100), 77.3% predates 1980 (55.4% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

## How Is Rocky Ford City Of's Municipal Water Supplied and Regulated?

Review Rocky Ford City Of's supply classification, customer headcount, local pre-1980 housing density, and 3-year Safe Drinking Water Act inspection metrics below.

EPA SDWA and local housing profile for Rocky Ford City Of (CO0145600)

| Water System Parameter | Measured / Reported Value | Benchmark / Federal Limit | Homeowner Impact |
|---|---|---|---|
| EPA Utility ID & Ownership | CO0145600 (Local Government) | Active CWS | Last sanitary visit: 03/11/2025 |
| Primary Source Water | Ground Water | GW vs. SW | Harder mineral load expected |
| Service Area & Population | 4,443 residents | #155 in Colorado | Counties: Otero |
| Served ZIP Codes | 81067 | 1 ZIP code | Verify utility on local municipal water bill |
| Pre-1980 Housing Share | 77.3% (55.4% pre-1960) | 1986 Lead Ban | Higher likelihood of legacy lead solder or galvanized laterals |
| 3-Year EPA SDWA Compliance | 1 rule violation (1 qtrs) | Zero health flags target | 5200=Lead And Copper Rule Revisions |
| State Tap Hardness Baseline | 9.6 GPG (Hard) | >= 7.0 GPG = Hard | Size ion-exchange resin on local grain test |

## What Do Federal PFAS Lab Results Show for Rocky Ford City Of?

See how Rocky Ford City Of (CO0145600) performed across federal UCMR 5 compounds alongside EPA's 4.0 ppt enforcement standard for PFOA and PFOS.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for CO0145600

| Regulated Compound / Screen | Max Detected | EPA Regulatory Standard | Compliance & Filtration Note |
|---|---|---|---|
| PFOA | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFOS | 4.1 ppt | 4.0 ppt EPA MCL | Exceeds EPA threshold — NSF 58 RO strongly advised |
| PFHxS | 6.0 ppt | 10 ppt EPA MCL | Detected below final EPA federal MCL |
| PFNA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| HFPO-DA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |

## Which Nearby Colorado Water Utilities Match This Profile?

Compare population scale, water source, and compliance status across four comparable community systems operating in Colorado.

Nearby community water systems in Colorado for side-by-side comparison

| Utility Name & PWSID | City / County | Population Served | Primary Source | Health Violations |
|---|---|---|---|---|
| [Menoken Wd](https://gcsradheat.com/water-quality/colorado/co0143506-menoken-wd/) (CO0143506) | Montrose | 4,500 | Surface / Mixed | 0 |
| [Frisco Town Of](https://gcsradheat.com/water-quality/colorado/co0159055-frisco-town-of/) (CO0159055) | Summit | 4,495 | Surface / Mixed | 0 |
| [Bennett Town Of](https://gcsradheat.com/water-quality/colorado/co0101020-bennett-town-of/) (CO0101020) | Adams | 4,400 | Groundwater | 0 |
| [Glendale City Of](https://gcsradheat.com/water-quality/colorado/co0103055-glendale-city-of/) (CO0103055) | Glendale | 4,400 | Surface / Mixed | 0 |

## When Should Rocky Ford City Of Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Otero; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

### Key Limitations & Exclusions

- Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
- Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
- Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

### Which Option Fits Your Situation?

**Pre-1980 Home or Young Family** Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.

**Installing a New Tankless Water Heater** Check tap hardness (9.6 GPG) and add scale inhibition on groundwater feeds.

## Practical Drinking Water Questions for Otero Residents

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Does Rocky Ford City Of draw from groundwater aquifers or surface water reservoirs?

EPA ECHO classifies Rocky Ford City Of (CO0145600) as a Ground Water community system serving 4,443 residents across Otero. Groundwater supplies draw from subsurface aquifers and typically carry higher dissolved calcium and magnesium carbonate, making annual tank flushing and scale protection important.

### What did federal UCMR 5 sampling measure in CO0145600?

Yes—UCMR 5 laboratory testing for CO0145600 recorded 5 PFAS detections peaking at 8.5 ppt (PFBS), which sits at or above EPA's 4.0 ppt enforceable MCL. NSF/ANSI 58 reverse osmosis or NSF 53 PFAS-rated carbon effectively reduces exposure at the drinking tap.

### How does local home age affect plumbing risk inside CO0145600's service area?

Across the 1 ZIP codes served by Rocky Ford City Of, approximately 77.3% of residential housing units were built before 1980 (55.4% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

## Related Colorado Pipe & Softener Links

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Menoken Wd (CO0143506)→](https://gcsradheat.com/water-quality/colorado/co0143506-menoken-wd/)
- [Compare Frisco Town Of (CO0159055)→](https://gcsradheat.com/water-quality/colorado/co0159055-frisco-town-of/)
- [Browse All Colorado Community Water Utilities→](https://gcsradheat.com/water-quality/colorado/)
- [Inspect Colorado County Well, Freeze & Pipe Data→](https://gcsradheat.com/counties/colorado/)
- [Check Well Water PFAS, Radon & Filtration Guide→](https://gcsradheat.com/guides/well-water-filtration-radon-pfas/)

## Sources

1. [EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download](https://echo.epa.gov/tools/data-downloads) — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
2. [Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State](https://www.epa.gov/dwucmr/occurrence-data-unregulated-contaminant-monitoring-rule) — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
3. [PFAS National Primary Drinking Water Regulation & LCRI Overview](https://www.epa.gov/sdwa/and-polyfluoroalkyl-substances-pfas) — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
4. [Lead and Copper Rule Improvements (LCRI) & Service Line Inventories](https://www.epa.gov/ground-water-and-drinking-water/lead-and-copper-rule-improvements) — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
5. [National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg)](https://www.waterqualitydata.us/data/Result/search) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
6. [U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File](https://www2.census.gov/programs-surveys/acs/summary_file/2023/table-based-SF/) — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Otero Tap Action

### Point-of-Use Reverse Osmosis (NSF/ANSI 58) or Catalytic Carbon (NSF 53)

For 4,443 customers on groundwater, focus on install nsf 58 ro + whole-house pre-filter before upgrading heaters.
[All Colorado Utilities](https://gcsradheat.com/water-quality/colorado/) [Check Softener Grain Sizing](https://gcsradheat.com/tools/water-softener-calculator/)
