---
title: "Mountain Village Town Of (CO0157400) Water Quality & PFAS"
url: https://gcsradheat.com/water-quality/colorado/co0157400-mountain-village-town-of/
description: "Mountain Village Town Of (CO0157400) is a Local Government public water utility serving 9,700 residents in San Miguel, Colorado primarily from ground water."
---

Colorado water passport · EPA CO0157400

# Mountain Village Town Of Water Quality, PFAS & Utility Report (CO0157400)

Mountain Village Town Of (CO0157400) is a Local Government public water utility serving 9,700 residents in San Miguel, Colorado primarily from ground water. EPA ECHO logs show zero EPA health violations alongside 3 monitoring/reporting notices, while UCMR 5 samples measured 8.1 ppt for PFHxS (exceeding the 4.0 ppt federal rule). Roughly 21.5% of homes across 1 served ZIP code predate 1980.

- **EPA PWSID** : CO0157400

- **Population Served** : 9,700

- **Water Source** : Groundwater

- **Max UCMR 5 PFAS** : 8.1 ppt (PFHxS)

- **3-Yr Health Flags** : 0 Health Viol.

Filtration & pipe verdict for Mountain Village Town Of

Because Mountain Village Town Of relies on groundwater wells, dissolved limestone and mineral salts commonly elevate scale formation inside tankless coils and electric water heater elements; Colorado's statewide USGS median is 9.6 GPG (Hard). UCMR 5 samples reached 8.1 ppt for PFHxS (at or above EPA's 4.0 ppt enforceable MCL). Prioritize an under-sink NSF/ANSI 58 RO membrane or NSF 53 PFAS-certified block filter for drinking and cooking water.

Across 5,033 housing units in Mountain Village Town Of's 1 ZIP code (median value $706,100), 21.5% predates 1980 (4.8% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

## What Are Mountain Village Town Of's Source Water, Population, and Pipe Risk Metrics?

Audited below are the core EPA ECHO distribution metrics, served ZIP codes, and local housing-era indicators shaping plumbing longevity in Mountain Village Town Of's network.

EPA SDWA and local housing profile for Mountain Village Town Of (CO0157400)

| Water System Parameter | Measured / Reported Value | Benchmark / Federal Limit | Homeowner Impact |
|---|---|---|---|
| EPA Utility ID & Ownership | CO0157400 (Local Government) | Active CWS | Last sanitary visit: 09/01/2020 |
| Primary Source Water | Ground Water | GW vs. SW | Harder mineral load expected |
| Service Area & Population | 9,700 residents | #102 in Colorado | Counties: San Miguel |
| Served ZIP Codes | 81435 | 1 ZIP code | Verify utility on local municipal water bill |
| Pre-1980 Housing Share | 21.5% (4.8% pre-1960) | 1986 Lead Ban | Mostly post-1980 copper or PEX piping |
| 3-Year EPA SDWA Compliance | 3 rule violations (6 qtrs) | Zero health flags target | 2992=Ethylbenzene, 4000=Gross Alpha, Excl. Radon And U, 4010=Combined Radium (-226 And -228) |
| State Tap Hardness Baseline | 9.6 GPG (Hard) | >= 7.0 GPG = Hard | Size ion-exchange resin on local grain test |

## Did CO0157400 Detect PFAS Under EPA UCMR 5 Sampling?

Compare measured UCMR 5 laboratory results for Mountain Village Town Of against EPA's enforceable 4.0 ppt PFOA/PFOS limits and state Consumer Confidence reporting.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for CO0157400

| Regulated Compound / Screen | Max Detected | EPA Regulatory Standard | Compliance & Filtration Note |
|---|---|---|---|
| PFOA | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFOS | 7.5 ppt | 4.0 ppt EPA MCL | Exceeds EPA threshold — NSF 58 RO strongly advised |
| PFHxS | 8.1 ppt | 10 ppt EPA MCL | Detected below final EPA federal MCL |
| PFNA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| HFPO-DA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |

## How Does Mountain Village Town Of Compare to Peer Colorado Utilities?

Review four nearby Colorado community water utilities matched by service rank inside Colorado's 175-utility public water catalog.

Nearby community water systems in Colorado for side-by-side comparison

| Utility Name & PWSID | City / County | Population Served | Primary Source | Health Violations |
|---|---|---|---|---|
| [Snake River Wd](https://gcsradheat.com/water-quality/colorado/co0159105-snake-river-wd/) (CO0159105) | Summit | 9,900 | Groundwater | 0 |
| [Morrison Town Of](https://gcsradheat.com/water-quality/colorado/co0130085-morrison-town-of/) (CO0130085) | Jefferson | 9,887 | Surface / Mixed | 0 |
| [St Charles Mesa Wd](https://gcsradheat.com/water-quality/colorado/co0151750-st-charles-mesa-wd/) (CO0151750) | Pueblo | 9,690 | Surface / Mixed | 0 |
| [Gunnison City Of](https://gcsradheat.com/water-quality/colorado/co0126325-gunnison-city-of/) (CO0126325) | Gunnison | 9,610 | Groundwater | 0 |

## When Should Mountain Village Town Of Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in San Miguel; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

### Key Limitations & Exclusions

- Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
- Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
- Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

### Which Option Fits Your Situation?

**Pre-1980 Home or Young Family** Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.

**Installing a New Tankless Water Heater** Check tap hardness (9.6 GPG) and add scale inhibition on groundwater feeds.

## Homeowner Water Quality FAQs for Mountain Village Town Of (CO0157400)

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Where does Mountain Village Town Of (CO0157400) source drinking water?

EPA ECHO classifies Mountain Village Town Of (CO0157400) as a Ground Water community system serving 9,700 residents across San Miguel. Groundwater supplies draw from subsurface aquifers and typically carry higher dissolved calcium and magnesium carbonate, making annual tank flushing and scale protection important.

### Were PFAS compounds detected in Mountain Village Town Of UCMR 5 testing?

Yes—UCMR 5 laboratory testing for CO0157400 recorded 4 PFAS detections peaking at 8.1 ppt (PFHxS), which sits at or above EPA's 4.0 ppt enforceable MCL. NSF/ANSI 58 reverse osmosis or NSF 53 PFAS-rated carbon effectively reduces exposure at the drinking tap.

### Could homes served by Mountain Village Town Of still face lead solder or older pipe risks?

Across the 1 ZIP codes served by Mountain Village Town Of, approximately 21.5% of residential housing units were built before 1980 (4.8% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

## Next Water Quality & State Guides for San Miguel

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Snake River Wd (CO0159105)→](https://gcsradheat.com/water-quality/colorado/co0159105-snake-river-wd/)
- [Compare Morrison Town Of (CO0130085)→](https://gcsradheat.com/water-quality/colorado/co0130085-morrison-town-of/)
- [Browse All Colorado Community Water Utilities→](https://gcsradheat.com/water-quality/colorado/)
- [Inspect Colorado County Well, Freeze & Pipe Data→](https://gcsradheat.com/counties/colorado/)
- [Check Well Water PFAS, Radon & Filtration Guide→](https://gcsradheat.com/guides/well-water-filtration-radon-pfas/)

## Sources

1. [EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download](https://echo.epa.gov/tools/data-downloads) — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
2. [Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State](https://www.epa.gov/dwucmr/occurrence-data-unregulated-contaminant-monitoring-rule) — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
3. [PFAS National Primary Drinking Water Regulation & LCRI Overview](https://www.epa.gov/sdwa/and-polyfluoroalkyl-substances-pfas) — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
4. [Lead and Copper Rule Improvements (LCRI) & Service Line Inventories](https://www.epa.gov/ground-water-and-drinking-water/lead-and-copper-rule-improvements) — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
5. [National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg)](https://www.waterqualitydata.us/data/Result/search) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
6. [U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File](https://www2.census.gov/programs-surveys/acs/summary_file/2023/table-based-SF/) — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Recommended for CO0157400

### Point-of-Use Reverse Osmosis (NSF/ANSI 58) or Catalytic Carbon (NSF 53)

Match filters to groundwater chemistry in San Miguel, CO. State hardness baseline: 9.6 GPG.
[All Colorado Utilities](https://gcsradheat.com/water-quality/colorado/) [Check Softener Grain Sizing](https://gcsradheat.com/tools/water-softener-calculator/)
