title: "Sunrise Springtree (FL4061410) Water Quality & PFAS"
url: https://gcsradheat.com/water-quality/florida/fl4061410-sunrise-springtree/
description: "Ranked #62 of 400 major community water utilities in Florida, Sunrise Springtree (FL4061410) delivers ground water to 79,550 people around Sunrise. Public."
---

EPA SDWA profile · FL4061410 (Florida)

# Sunrise Springtree Water Quality, PFAS & Utility Report (FL4061410)

Ranked #62 of 400 major community water utilities in Florida, Sunrise Springtree (FL4061410) delivers ground water to 79,550 people around Sunrise. Public records indicate zero EPA health violations alongside 4 monitoring/reporting notices and note that UCMR 5 samples measured 11.0 ppt for PFOS (exceeding the 4.0 ppt federal rule). Recommended home check: Install NSF 58 under-sink RO or NSF 53 PFAS carbon.

- **EPA PWSID** : FL4061410

- **Population Served** : 79,550

- **Water Source** : Groundwater

- **Max UCMR 5 PFAS** : 11.0 ppt (PFOS)

- **3-Yr Health Flags** : 0 Health Viol.

Homeowner takeaway for FL4061410

Because Sunrise Springtree relies on groundwater wells, dissolved limestone and mineral salts commonly elevate scale formation inside tankless coils and electric water heater elements; Florida's statewide USGS median is 2.3 GPG (Soft). UCMR 5 samples reached 11.0 ppt for PFOS (at or above EPA's 4.0 ppt enforceable MCL). Prioritize an under-sink NSF/ANSI 58 RO membrane or NSF 53 PFAS-certified block filter for drinking and cooking water.

Across 360,373 housing units in Sunrise Springtree's 25 ZIP codes (median value $446,591), 55.3% predates 1980 (12.7% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

## Which Compliance and Housing Indicators Define FL4061410?

These verified utility measurements pair EPA SDWIS facility data for Sunrise Springtree with Census housing vintage across its 25 served ZIP codes.

EPA SDWA and local housing profile for Sunrise Springtree (FL4061410)

| Water System Parameter | Measured / Reported Value | Benchmark / Federal Limit | Homeowner Impact |
|---|---|---|---|
| EPA Utility ID & Ownership | FL4061410 (Local Government) | Active CWS | Last sanitary visit: 02/22/2024 |
| Primary Source Water | Ground Water | GW vs. SW | Harder mineral load expected |
| Service Area & Population | 79,550 residents | #62 in Florida | Counties: Broward |
| Served ZIP Codes | 33021, 33022, 33023, 33301, 33309, 33311, 33312, 33313 (+17 more) | 25 ZIP codes | Verify utility on local municipal water bill |
| Pre-1980 Housing Share | 55.3% (12.7% pre-1960) | 1986 Lead Ban | Higher likelihood of legacy lead solder or galvanized laterals |
| 3-Year EPA SDWA Compliance | 4 rule violations (10 qtrs) | Zero health flags target | 1040=Nitrate, 2456=Total Haloacetic Acids (Haa5), 2950=Tthm, 7000=Consumer Confidence Rule |
| State Tap Hardness Baseline | 2.3 GPG (Soft) | >= 7.0 GPG = Hard | Moderate mineral profile |

## How Do Sunrise Springtree PFAS Levels Stack Up Against 4.0 ppt Rules?

EPA's National Primary Drinking Water Regulation sets strict 4.0 ppt limits on PFOA and PFOS; inspect Sunrise Springtree's monitored results below.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for FL4061410

| Regulated Compound / Screen | Max Detected | EPA Regulatory Standard | Compliance & Filtration Note |
|---|---|---|---|
| PFOA | 4.9 ppt | 4.0 ppt EPA MCL | Exceeds EPA threshold — NSF 58 RO strongly advised |
| PFOS | 11.0 ppt | 4.0 ppt EPA MCL | Exceeds EPA threshold — NSF 58 RO strongly advised |
| PFHxS | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFNA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| HFPO-DA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |

## What Do Neighboring Community Water Systems Report in Florida?

Cross-check four peer Florida water utilities to see how Sunrise Springtree ranks by system size, groundwater reliance, and EPA notices.

Nearby community water systems in Florida for side-by-side comparison

| Utility Name & PWSID | City / County | Population Served | Primary Source | Health Violations |
|---|---|---|---|---|
| [Homestead, City Of](https://gcsradheat.com/water-quality/florida/fl4130645-homestead-city-of/) (FL4130645) | Homestead | 80,000 | Groundwater | 0 |
| [Sanford, City Of (2 Wps)](https://gcsradheat.com/water-quality/florida/fl3590205-sanford-city-of-2-wps/) (FL3590205) | Sanford | 79,715 | Groundwater | 0 |
| [Bonita Springs Utilities](https://gcsradheat.com/water-quality/florida/fl5360025-bonita-springs-utilities/) (FL5360025) | Bonita Springs | 76,033 | Groundwater | 0 |
| [Bcwws 1A](https://gcsradheat.com/water-quality/florida/fl4060167-bcwws-1a/) (FL4060167) | Lauderdale Lakes | 75,305 | Groundwater | 0 |

## When Should Sunrise Springtree Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Sunrise; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

### Key Limitations & Exclusions

- Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
- Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
- Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

### Which Option Fits Your Situation?

**Pre-1980 Home or Young Family** Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.

**Installing a New Tankless Water Heater** Check tap hardness (2.3 GPG) and add scale inhibition on groundwater feeds.

## Key Questions About Tap Water From Sunrise Springtree

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### What water source serves the 79,550 customers under EPA ID FL4061410?

EPA ECHO classifies Sunrise Springtree (FL4061410) as a Ground Water community system serving 79,550 residents across Broward. Groundwater supplies draw from subsurface aquifers and typically carry higher dissolved calcium and magnesium carbonate, making annual tank flushing and scale protection important.

### How do Sunrise Springtree PFAS levels compare to EPA's 4.0 ppt federal limit?

Yes—UCMR 5 laboratory testing for FL4061410 recorded 6 PFAS detections peaking at 11.0 ppt (PFOS), which sits at or above EPA's 4.0 ppt enforceable MCL. NSF/ANSI 58 reverse osmosis or NSF 53 PFAS-rated carbon effectively reduces exposure at the drinking tap.

### What pipe materials should homeowners served by Sunrise Springtree inspect?

Across the 22 ZIP codes served by Sunrise Springtree, approximately 55.3% of residential housing units were built before 1980 (12.7% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

## Additional Water Softener & Code Tools for FL

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Homestead, City Of (FL4130645)→](https://gcsradheat.com/water-quality/florida/fl4130645-homestead-city-of/)
- [Compare Sanford, City Of (2 Wps) (FL3590205)→](https://gcsradheat.com/water-quality/florida/fl3590205-sanford-city-of-2-wps/)
- [Browse All Florida Community Water Utilities→](https://gcsradheat.com/water-quality/florida/)
- [Inspect Florida County Well, Freeze & Pipe Data→](https://gcsradheat.com/counties/florida/)
- [Check Well Water PFAS, Radon & Filtration Guide→](https://gcsradheat.com/guides/well-water-filtration-radon-pfas/)

## Sources

1. [EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download](https://echo.epa.gov/tools/data-downloads) — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
2. [Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State](https://www.epa.gov/dwucmr/occurrence-data-unregulated-contaminant-monitoring-rule) — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
3. [PFAS National Primary Drinking Water Regulation & LCRI Overview](https://www.epa.gov/sdwa/and-polyfluoroalkyl-substances-pfas) — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
4. [Lead and Copper Rule Improvements (LCRI) & Service Line Inventories](https://www.epa.gov/ground-water-and-drinking-water/lead-and-copper-rule-improvements) — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
5. [National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg)](https://www.waterqualitydata.us/data/Result/search) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
6. [U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File](https://www2.census.gov/programs-surveys/acs/summary_file/2023/table-based-SF/) — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Filter Spec (FL)

### Point-of-Use Reverse Osmosis (NSF/ANSI 58) or Catalytic Carbon (NSF 53)

Serving Sunrise via groundwater; confirm cartridge micron & NSF 53/58 certifications locally.
[All Florida Utilities](https://gcsradheat.com/water-quality/florida/) [Check Softener Grain Sizing](https://gcsradheat.com/tools/water-softener-calculator/)