title: "Rosemont (IL0312760) Water Quality & PFAS"
url: https://gcsradheat.com/water-quality/illinois/il0312760-rosemont/
description: "Rosemont (IL0312760) is a Local Government public water utility serving 3,952 residents in Rosemont, Illinois primarily from surface water purchased. EPA ECHO."
---

Illinois water passport · EPA IL0312760

# Rosemont Water Quality, PFAS & Utility Report (IL0312760)

Rosemont (IL0312760) is a Local Government public water utility serving 3,952 residents in Rosemont, Illinois primarily from surface water purchased. EPA ECHO logs show zero 3-year EPA health or monitoring rule violations on record, while all 120 federal UCMR 5 PFAS lab runs tested non-detect. Roughly 70.2% of homes across 3 served ZIP codes predate 1980.

- **EPA PWSID** : IL0312760

- **Population Served** : 3,952

- **Water Source** : Surface Water

- **Max UCMR 5 PFAS** : 0 ppt Detected

- **3-Yr Health Flags** : 0 Health Viol.

Filtration & pipe verdict for Rosemont

Drawing surface water across Rosemont, Rosemont uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. Surface water utilities disinfect with chlorine or chloramines; catalytic carbon cartridges remove taste, odor, and trihalomethane (TTHM) byproducts at the kitchen tap.

Across 41,469 housing units in Rosemont's 3 ZIP codes (median value $331,533), 70.2% predates 1980 (39.7% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

## What Are Rosemont's Source Water, Population, and Pipe Risk Metrics?

Audited below are the core EPA ECHO distribution metrics, served ZIP codes, and local housing-era indicators shaping plumbing longevity in Rosemont's network.

EPA SDWA and local housing profile for Rosemont (IL0312760)

| Water System Parameter | Measured / Reported Value | Benchmark / Federal Limit | Homeowner Impact |
|---|---|---|---|
| EPA Utility ID & Ownership | IL0312760 (Local Government) | Active CWS | Last sanitary visit: 02/24/2025 |
| Primary Source Water | Surface Water Purchased | GW vs. SW | Disinfection byproduct check recommended |
| Service Area & Population | 3,952 residents | #409 in Illinois | Counties: Cook |
| Served ZIP Codes | 60018, 60653, 60656 | 3 ZIP codes | Verify utility on local municipal water bill |
| Pre-1980 Housing Share | 70.2% (39.7% pre-1960) | 1986 Lead Ban | Higher likelihood of legacy lead solder or galvanized laterals |
| 3-Year EPA SDWA Compliance | 0 rule violations (0 qtrs) | Zero health flags target | No health-based compliance flags |
| State Tap Hardness Baseline | Unmonitored in USGS extract | >= 7.0 GPG = Hard | Moderate mineral profile |

## Did IL0312760 Detect PFAS Under EPA UCMR 5 Sampling?

Compare measured UCMR 5 laboratory results for Rosemont against EPA's enforceable 4.0 ppt PFOA/PFOS limits and state Consumer Confidence reporting.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for IL0312760

| Regulated Compound / Screen | Max Detected | EPA Regulatory Standard | Compliance & Filtration Note |
|---|---|---|---|
| PFOA | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFOS | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFHxS | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFNA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| HFPO-DA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| Lead / Copper 90th Pct | Pb: 1 / Cu: — | 10 ppb Lead (LCRI) / 1.3 ppm Cu | Utility distribution sample |

## How Does Rosemont Compare to Peer Illinois Utilities?

Review four nearby Illinois community water utilities matched by service rank inside Illinois's 454-utility public water catalog.

Nearby community water systems in Illinois for side-by-side comparison

| Utility Name & PWSID | City / County | Population Served | Primary Source | Health Violations |
|---|---|---|---|---|
| [North East Central Pwd](https://gcsradheat.com/water-quality/illinois/il1195280-north-east-central-pwd/) (IL1195280) | Madison | 3,975 | Groundwater | 0 |
| [Hamilton County Water District](https://gcsradheat.com/water-quality/illinois/il0651000-hamilton-county-water-district/) (IL0651000) | Hamilton | 3,958 | Surface / Mixed | 0 |
| [Marshall](https://gcsradheat.com/water-quality/illinois/il0230100-marshall/) (IL0230100) | Marshall | 3,947 | Groundwater | 0 |
| [Corinth Pwd](https://gcsradheat.com/water-quality/illinois/il1995120-corinth-pwd/) (IL1995120) | Williamson | 3,927 | Surface / Mixed | 0 |

## When Should Rosemont Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Rosemont; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

### Key Limitations & Exclusions

- Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
- Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
- Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

### Which Option Fits Your Situation?

**Pre-1980 Home or Young Family** Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.

**Installing a New Tankless Water Heater** Check tap hardness (7+ GPG) and add scale inhibition on groundwater feeds.

## Homeowner Water Quality FAQs for Rosemont (IL0312760)

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Where does Rosemont (IL0312760) source drinking water?

EPA ECHO classifies Rosemont (IL0312760) as a Surface Water Purchased community system serving 3,952 residents across Cook. Surface supplies pull from rivers, lakes, or reservoirs and require chlorine or chloramine disinfection plus monitoring for disinfection byproducts.

### Were PFAS compounds detected in Rosemont UCMR 5 testing?

Federal UCMR 5 sampling covering 120 laboratory tests for Rosemont reported zero quantifiable PFAS compounds above reporting limits, well under the 4.0 ppt federal PFOA/PFOS rule.

### Could homes served by Rosemont still face lead solder or older pipe risks?

Across the 3 ZIP codes served by Rosemont, approximately 70.2% of residential housing units were built before 1980 (39.7% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

## Next Water Quality & State Guides for Rosemont

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare North East Central Pwd (IL1195280)→](https://gcsradheat.com/water-quality/illinois/il1195280-north-east-central-pwd/)
- [Compare Hamilton County Water District (IL0651000)→](https://gcsradheat.com/water-quality/illinois/il0651000-hamilton-county-water-district/)
- [Browse All Illinois Community Water Utilities→](https://gcsradheat.com/water-quality/illinois/)
- [Inspect Illinois County Well, Freeze & Pipe Data→](https://gcsradheat.com/counties/illinois/)
- [Check Well Water PFAS, Radon & Filtration Guide→](https://gcsradheat.com/guides/well-water-filtration-radon-pfas/)

## Sources

1. [EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download](https://echo.epa.gov/tools/data-downloads) — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
2. [Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State](https://www.epa.gov/dwucmr/occurrence-data-unregulated-contaminant-monitoring-rule) — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
3. [PFAS National Primary Drinking Water Regulation & LCRI Overview](https://www.epa.gov/sdwa/and-polyfluoroalkyl-substances-pfas) — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
4. [Lead and Copper Rule Improvements (LCRI) & Service Line Inventories](https://www.epa.gov/ground-water-and-drinking-water/lead-and-copper-rule-improvements) — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
5. [National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg)](https://www.waterqualitydata.us/data/Result/search) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
6. [U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File](https://www2.census.gov/programs-surveys/acs/summary_file/2023/table-based-SF/) — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Recommended for IL0312760

### NSF/ANSI 42/53 Carbon Block for Chloramine / Disinfection Byproducts

Match filters to surface water chemistry in Rosemont, IL. State hardness baseline: Check CCR GPG.
[All Illinois Utilities](https://gcsradheat.com/water-quality/illinois/) [Check Softener Grain Sizing](https://gcsradheat.com/tools/water-softener-calculator/)