title: "Southwestern Bartholomew Water Corp. (IN5203008) Water Quality"
url: https://gcsradheat.com/water-quality/indiana/in5203008-southwestern-bartholomew-water-corp/
description: "Supplying 8,652 customers across Bartholomew, Indiana, Southwestern Bartholomew Water Corp. (EPA ID IN5203008) relies on ground water purchased for daily."
---

Utility quality file · Columbus, IN (IN5203008)

# Southwestern Bartholomew Water Corp. Water Quality, PFAS & Utility Report (IN5203008)

Supplying 8,652 customers across Bartholomew, Indiana, Southwestern Bartholomew Water Corp. (EPA ID IN5203008) relies on ground water purchased for daily municipal flow. Current federal compliance files record zero 3-year EPA health or monitoring rule violations on record; meanwhile UCMR 5 samples measured 8.7 ppt for PFBS (exceeding the 4.0 ppt federal rule), and 47.9% of homes across 2 served ZIP codes predate 1980.

- **EPA PWSID** : IN5203008

- **Population Served** : 8,652

- **Water Source** : Groundwater

- **Max UCMR 5 PFAS** : 8.7 ppt (PFBS)

- **3-Yr Health Flags** : 0 Health Viol.

Tap treatment summary — IN5203008

Because Southwestern Bartholomew Water Corp. relies on groundwater wells, dissolved limestone and mineral salts commonly elevate scale formation inside tankless coils and electric water heater elements; Indiana's statewide USGS median is 6.8 GPG (Moderately Hard). UCMR 5 samples reached 8.7 ppt for PFBS (at or above EPA's 4.0 ppt enforceable MCL). Prioritize an under-sink NSF/ANSI 58 RO membrane or NSF 53 PFAS-certified block filter for drinking and cooking water.

Across 24,919 housing units in Southwestern Bartholomew Water Corp.'s 2 ZIP codes (median value $231,600), 47.9% predates 1980 (28.4% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

## How Is Southwestern Bartholomew Water Corp.'s Municipal Water Supplied and Regulated?

Review Southwestern Bartholomew Water Corp.'s supply classification, customer headcount, local pre-1980 housing density, and 3-year Safe Drinking Water Act inspection metrics below.

EPA SDWA and local housing profile for Southwestern Bartholomew Water Corp. (IN5203008)

| Water System Parameter | Measured / Reported Value | Benchmark / Federal Limit | Homeowner Impact |
|---|---|---|---|
| EPA Utility ID & Ownership | IN5203008 (Local Government) | Active CWS | Last sanitary visit: 08/14/2024 |
| Primary Source Water | Ground Water Purchased | GW vs. SW | Harder mineral load expected |
| Service Area & Population | 8,652 residents | #106 in Indiana | Counties: Bartholomew |
| Served ZIP Codes | 47201, 47448 | 2 ZIP codes | Verify utility on local municipal water bill |
| Pre-1980 Housing Share | 47.9% (28.4% pre-1960) | 1986 Lead Ban | Higher likelihood of legacy lead solder or galvanized laterals |
| 3-Year EPA SDWA Compliance | 0 rule violations (0 qtrs) | Zero health flags target | No health-based compliance flags |
| State Tap Hardness Baseline | 6.8 GPG (Moderately Hard) | >= 7.0 GPG = Hard | Moderate mineral profile |

## What Do Federal PFAS Lab Results Show for Southwestern Bartholomew Water Corp.?

See how Southwestern Bartholomew Water Corp. (IN5203008) performed across federal UCMR 5 compounds alongside EPA's 4.0 ppt enforcement standard for PFOA and PFOS.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for IN5203008

| Regulated Compound / Screen | Max Detected | EPA Regulatory Standard | Compliance & Filtration Note |
|---|---|---|---|
| PFOA | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFOS | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFHxS | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFNA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| HFPO-DA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |

## Which Nearby Indiana Water Utilities Match This Profile?

Compare population scale, water source, and compliance status across four comparable community systems operating in Indiana.

Nearby community water systems in Indiana for side-by-side comparison

| Utility Name & PWSID | City / County | Population Served | Primary Source | Health Violations |
|---|---|---|---|---|
| [Hoosier Hills Regional Water District](https://gcsradheat.com/water-quality/indiana/in5269002-hoosier-hills-regional-water-district/) (IN5269002) | Milan | 8,660 | Groundwater | 0 |
| [Indiana American Water - Charlestown](https://gcsradheat.com/water-quality/indiana/in5210003-indiana-american-water-charlestown/) (IN5210003) | Charlestown | 8,658 | Groundwater | 0 |
| [Rural Membership Water Corp. Of Clark Co](https://gcsradheat.com/water-quality/indiana/in5210009-rural-membership-water-corp-of-clark-co/) (IN5210009) | Henryville | 8,630 | Groundwater | 0 |
| [East Washington Rural Water](https://gcsradheat.com/water-quality/indiana/in5288002-east-washington-rural-water/) (IN5288002) | Salem | 8,613 | Surface / Mixed | 0 |

## When Should Southwestern Bartholomew Water Corp. Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Columbus; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

### Key Limitations & Exclusions

- Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
- Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
- Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

### Which Option Fits Your Situation?

**Pre-1980 Home or Young Family** Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.

**Installing a New Tankless Water Heater** Check tap hardness (6.8 GPG) and add scale inhibition on groundwater feeds.

## Practical Drinking Water Questions for Columbus Residents

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Does Southwestern Bartholomew Water Corp. draw from groundwater aquifers or surface water reservoirs?

EPA ECHO classifies Southwestern Bartholomew Water Corp. (IN5203008) as a Ground Water Purchased community system serving 8,652 residents across Bartholomew. Groundwater supplies draw from subsurface aquifers and typically carry higher dissolved calcium and magnesium carbonate, making annual tank flushing and scale protection important.

### What did federal UCMR 5 sampling measure in IN5203008?

Yes—UCMR 5 laboratory testing for IN5203008 recorded 1 PFAS detections peaking at 8.7 ppt (PFBS), which sits at or above EPA's 4.0 ppt enforceable MCL. NSF/ANSI 58 reverse osmosis or NSF 53 PFAS-rated carbon effectively reduces exposure at the drinking tap.

### How does local home age affect plumbing risk inside IN5203008's service area?

Across the 2 ZIP codes served by Southwestern Bartholomew Water Corp., approximately 47.9% of residential housing units were built before 1980 (28.4% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

## Related Indiana Pipe & Softener Links

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Hoosier Hills Regional Water District (IN5269002)→](https://gcsradheat.com/water-quality/indiana/in5269002-hoosier-hills-regional-water-district/)
- [Compare Indiana American Water - Charlestown (IN5210003)→](https://gcsradheat.com/water-quality/indiana/in5210003-indiana-american-water-charlestown/)
- [Browse All Indiana Community Water Utilities→](https://gcsradheat.com/water-quality/indiana/)
- [Inspect Indiana County Well, Freeze & Pipe Data→](https://gcsradheat.com/counties/indiana/)
- [Check Well Water PFAS, Radon & Filtration Guide→](https://gcsradheat.com/guides/well-water-filtration-radon-pfas/)

## Sources

1. [EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download](https://echo.epa.gov/tools/data-downloads) — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
2. [Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State](https://www.epa.gov/dwucmr/occurrence-data-unregulated-contaminant-monitoring-rule) — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
3. [PFAS National Primary Drinking Water Regulation & LCRI Overview](https://www.epa.gov/sdwa/and-polyfluoroalkyl-substances-pfas) — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
4. [Lead and Copper Rule Improvements (LCRI) & Service Line Inventories](https://www.epa.gov/ground-water-and-drinking-water/lead-and-copper-rule-improvements) — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
5. [National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg)](https://www.waterqualitydata.us/data/Result/search) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
6. [U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File](https://www2.census.gov/programs-surveys/acs/summary_file/2023/table-based-SF/) — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Columbus Tap Action

### Point-of-Use Reverse Osmosis (NSF/ANSI 58) or Catalytic Carbon (NSF 53)

For 8,652 customers on groundwater, focus on install nsf 58 under-sink ro or nsf 53 pfas carbon before upgrading heaters.
[All Indiana Utilities](https://gcsradheat.com/water-quality/indiana/) [Check Softener Grain Sizing](https://gcsradheat.com/tools/water-softener-calculator/)